Determination of surgical margins in laparoscopic parenchyma-sparing hepatectomy of neuroendocrine tumors liver metastases using indocyanine green fluorescence imaging

被引:6
|
作者
Wang, Gaoming [1 ]
Luo, Ying [2 ]
Qi, Weijun [1 ]
Yuan, Chunhui [1 ]
Xiu, Dianrong [1 ]
机构
[1] Peking Univ Third Hosp, Dept Gen Surg, Beijing 100191, Peoples R China
[2] Peking Univ Third Hosp, Dept Respirat, Beijing, Peoples R China
关键词
Indocyanine green fluorescence imaging; Surgical margins; Laparoscopic parenchyma-sparing hepatectomy; Neuroendocrine tumors liver metastasis; RESECTION; MANAGEMENT; SURVIVAL; SURGERY;
D O I
10.1007/s00464-021-08791-6
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background Neuroendocrine tumors (NETs) are a group of heterogenous tumors originating from neuroendocrine system. Approximately, 40 percent will go through liver metastases, and liver-directed therapy was proved to improve the survival outcome. Parenchyma-sparing hepatectomy is advocated for the resection of NETs liver metastases while the possible relatively low negative margin rate is concerned. Indocyanine green (ICG) fluorescence imaging provides a real-time navigation on determination of surgical margins in colorectal cancer liver metastases. However, there was no previous study that reported the applications of ICG fluorescence imaging in NETs liver metastases. The present study aimed to evaluate the feasibility and security of using ICG fluorescence imaging to determine surgical margins of NETs liver metastases during operation. Methods A retrospective two-arm cohort study was performed on 25 consecutive patients with NETs liver metastases who underwent laparoscopic parenchyma-sparing hepatectomy (LPSH). Patients were divided into two groups according to whether or not the ICG fluorescence imaging was used. Data on sociodemographic characteristics, laboratory parameters, pathology results, and surgical outcomes were collected. Results A total of 145 tumors pathologically diagnosed with NETs liver metastases were resected from 25 patients. The pathological results indicated negative margins in all tumors (102/102) in LPSH with ICG fluorescence imaging group. The negative margin rate was significantly higher in LPSH using the ICG fluorescence imaging (100% v.s 88.4%, p = 0.002). Surgical outcomes, including operation time, estimated blood loss, intraoperative transfusion rate, and postoperative morbidity, were comparable between LPSH with and without ICG fluorescence imaging groups. Conclusion ICG fluorescence imaging showed the potential to identify tumor boundaries and determine surgical margins. This technique may serve as a valuable intraoperative navigation in patients with NETs liver metastases.
引用
收藏
页码:4408 / 4416
页数:9
相关论文
共 50 条
  • [1] Determination of surgical margins in laparoscopic parenchyma-sparing hepatectomy of neuroendocrine tumors liver metastases using indocyanine green fluorescence imaging
    Gaoming Wang
    Ying Luo
    Weijun Qi
    Chunhui Yuan
    Dianrong Xiu
    Surgical Endoscopy, 2022, 36 : 4408 - 4416
  • [2] Role of indocyanine green fluorescence imaging in margin assessment and recurrence-free survival in laparoscopic parenchyma-sparing hepatectomy for neuroendocrine tumor liver metastases
    Gaoming Wang
    Chenghao Liu
    Weijun Qi
    Long Li
    Dianrong Xiu
    Surgical Endoscopy, 2025, 39 (3) : 1574 - 1582
  • [3] Parenchyma-Sparing Hepatectomy or Major Hepatectomy for Colorectal Liver Metastases?
    Inoue, Yoshihiro
    Ishii, Masatsugu
    Tashiro, Keitaro
    Ueda, Yasuhiko
    Suzuki, Yusuke
    Ota, Masato
    Fujii, Kensuke
    Masubuchi, Shinsuke
    Yamamoto, Masashi
    Hirokawa, Fumitoshi
    Hayashi, Michihiro
    Uchiyama, Kazuhisa
    AMERICAN SURGEON, 2018, 84 (06) : E181 - E184
  • [4] Laparoscopic parenchyma-sparing liver resection for colorectal metastases
    Aghayan, Davit L.
    Pelanis, Egidijus
    Fretland, Asmund Avdem
    Kazaryan, Airazat M.
    Sahakyan, Mushegh A.
    Rosok, Bard I.
    Barkhatov, Leonid
    Bjornbeth, Bjorn Atle
    Elle, Ole Jakob
    Edwin, Bjorn
    RADIOLOGY AND ONCOLOGY, 2018, 52 (01) : 36 - 41
  • [5] Laparoscopic Multiple Parenchyma-sparing Concomitant Liver Resections for Colorectal Liver Metastases
    Kazaryan, Airazat M.
    Aghayan, David L.
    Barkhatov, Leonid I.
    Fretland, Asmund A.
    Edwin, Bjorn
    SURGICAL LAPAROSCOPY ENDOSCOPY & PERCUTANEOUS TECHNIQUES, 2019, 29 (03): : 187 - 193
  • [6] Laparoscopic parenchyma-sparing liver resection for large (≥ 50 mm) colorectal metastases
    Aghayan, Davit L.
    d'Albenzio, Gabriella
    Fretland, Asmund A.
    Pelanis, Egidijus
    Rosok, Bard I.
    Yaqub, Sheraz
    Palomar, Rafael
    Edwin, Bjorn
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2023, 37 (01): : 225 - 233
  • [7] Laparoscopic parenchyma-sparing liver resection for large (≥ 50 mm) colorectal metastases
    Davit L. Aghayan
    Gabriella d’Albenzio
    Åsmund A. Fretland
    Egidijus Pelanis
    Bård I. Røsok
    Sheraz Yaqub
    Rafael Palomar
    Bjørn Edwin
    Surgical Endoscopy, 2023, 37 : 225 - 233
  • [8] Determination of the surgical margin in laparoscopic liver resections using infrared indocyanine green fluorescence
    Takeshi Aoki
    Masahiko Murakami
    Tomotake Koizumi
    Kazuhiro Matsuda
    Akira Fujimori
    Tomokazu Kusano
    Yuta Enami
    Satoru Goto
    Makoto Watanabe
    Koji Otsuka
    Langenbeck's Archives of Surgery, 2018, 403 : 671 - 680
  • [9] Determination of the surgical margin in laparoscopic liver resections using infrared indocyanine green fluorescence
    Aoki, Takeshi
    Murakami, Masahiko
    Koizumi, Tomotake
    Matsuda, Kazuhiro
    Fujimori, Akira
    Kusano, Tomokazu
    Enami, Yuta
    Goto, Satoru
    Watanabe, Makoto
    Otsuka, Koji
    LANGENBECKS ARCHIVES OF SURGERY, 2018, 403 (05) : 671 - 680
  • [10] Applications of fusion-fluorescence imaging using indocyanine green in laparoscopic hepatectomy
    Terasawa, Muga
    Ishizawa, Takeaki
    Mise, Yoshihiro
    Inoue, Yosuke
    Ito, Hiromichi
    Takahashi, Yu
    Saiura, Akio
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2017, 31 (12): : 5111 - 5118