BatchBMD as an Efficient and Accurate Dual-Energy X-ray Absorptiometry Report Generator

被引:0
作者
Chan, Chun-Hsiang [1 ,2 ]
Huang, Wen-Chi [3 ]
Lu, Yi-Chien [1 ]
Hsiao, Hsing-Fen [1 ]
Chan, Wing P. [1 ,2 ]
机构
[1] Taipei Med Univ, Dept Radiol, Wan Fang Hosp, Taipei 116, Taiwan
[2] Taipei Med Univ, Coll Med, Sch Med, Dept Radiol, Taipei 110, Taiwan
[3] Natl Taiwan Univ, Dept Comp Sci & Informat Engn, Taipei 106, Taiwan
关键词
dual-energy X-ray absorptiometry; bone mineral density; automated reporting system; FRACTURE RISK; OSTEOPOROSIS; QUALITY; IMPROVE; HEALTH; DXA;
D O I
10.3390/diagnostics11122403
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Dual-energy X-ray absorptiometry is the gold standard for evaluating Bone Mineral Density (BMD); however, a typical BMD report is generated in a time-inefficient manner and is prone to error. We developed a rule-based automated reporting system, BatchBMD, that accelerates DXA reporting while improving its accuracy over current systems. BatchBMD generates a structured report, customized to the specific clinical purpose. To compare BatchBMD to a Web-based Reporting (WBR) system for efficiency and accuracy, 500 examinations were randomly chosen from those performed at the Taipei Municipal Wanfang Hospital from January to March 2021. The final assessment included all 2326 examinations conducted from September 2020 to March 2021. The average reporting times were 6.7 and 10.8 min for BatchBMD and the WBR system, respectively, while accuracy was 99.4% and 98.2%, respectively. Most of the errors made by BatchBMD were digit errors in the appendicular skeletal muscle index. After correcting this, 100% accuracy across all 2326 examinations was validated. This automated and accurate BMD reporting system significantly reduces report production workload for radiologists and technicians while increasing productivity and quality. Additionally, the portable software, which employs a simple framework, can reduce deployment costs in clinical practice.
引用
收藏
页数:9
相关论文
共 30 条
[11]   ASSESSMENT OF FRACTURE RISK AND ITS APPLICATION TO SCREENING FOR POSTMENOPAUSAL OSTEOPOROSIS - SYNOPSIS OF A WHO REPORT [J].
KANIS, JA ;
ALEXEEVA, L ;
BONJOUR, JP ;
BURKHARDT, P ;
CHRISTIANSEN, C ;
COOPER, C ;
DELMAS, P ;
JOHNELL, O ;
JOHNSTON, C ;
KANIS, JA ;
KHALTAEV, N ;
LIPS, P ;
MAZZUOLI, G ;
MELTON, LJ ;
MEUNIER, P ;
SEEMAN, E ;
STEPAN, J ;
TOSTESON, A .
OSTEOPOROSIS INTERNATIONAL, 1994, 4 (06) :368-381
[12]   FRAX® and its applications to clinical practice [J].
Kanis, John A. ;
Oden, Anders ;
Johansson, Helena ;
Borgstrom, Fredrik ;
Strom, Oskar ;
McCloskey, Eugene .
BONE, 2009, 44 (05) :734-743
[13]   Association between screening for osteoporosis and the incidence of hip fracture [J].
Kern, LM ;
Powe, NR ;
Levine, MA ;
Fitzpatrick, AL ;
Harris, TB ;
Robbins, J ;
Fried, LP .
ANNALS OF INTERNAL MEDICINE, 2005, 142 (03) :173-181
[14]   Can Health IT Tools Enable Improved Documentation of Quality, Safety Measures, and Regulatory Requirements in Radiology Reports? [J].
Khorasani, Ramin .
JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2013, 10 (05) :381-382
[15]   Structured reporting has the potential to reduce reporting times of dual-energy x-ray absorptiometry exams [J].
Kim, Su Hwan ;
Sobez, Lara M. ;
Spiro, Judith E. ;
Curta, Adrian ;
Ceelen, Felix ;
Kampmann, Eric ;
Goepfert, Martin ;
Bodensohn, Raphael ;
Meinel, Felix G. ;
Sommer, Wieland H. ;
Sommer, Nora N. ;
Galie, Franziska .
BMC MUSCULOSKELETAL DISORDERS, 2020, 21 (01)
[16]   DXA Errors Are Common and Reduced by Use of a Reporting Template [J].
Krueger, D. ;
Shives, E. ;
Siglinsky, E. ;
Libber, J. ;
Buehring, B. ;
Hansen, K. E. ;
Binkley, N. .
JOURNAL OF CLINICAL DENSITOMETRY, 2019, 22 (01) :115-124
[17]   Quantitative Computed Tomography (QCT) as a Radiology Reporting Tool by Using Optical Character Recognition (OCR) and Macro Program [J].
Lee, Young Han ;
Song, Ho-Taek ;
Suh, Jin-Suck .
JOURNAL OF DIGITAL IMAGING, 2012, 25 (06) :815-818
[18]   Bone Mineral Densitometry Reporting: Pearls and Pitfalls [J].
Martineau, Patrick ;
Morgan, Sarah L. ;
Leslie, William D. .
CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2021, 72 (03) :490-504
[19]   Prevalence and type of errors in dual-energy x-ray absorptiometry [J].
Messina, Carmelo ;
Bandirali, Michele ;
Sconfienza, Luca Maria ;
D'Alonzo, Nathascja Katia ;
Di Leo, Giovanni ;
Papini, Giacomo Davide Edoardo ;
Ulivieri, Fabio Massimo ;
Sardanelli, Francesco .
EUROPEAN RADIOLOGY, 2015, 25 (05) :1504-1511
[20]   The history of bone densitometry [J].
Miller, Paul D. .
BONE, 2017, 104 :4-6