Novel Assessment of Isometric Hip Extensor Function: Reliability, Joint Angle Sensitivity, and Concurrent Validity

被引:7
作者
Goodwin, Jon E. [1 ,2 ]
Bull, Anthony M. J. [1 ,2 ]
机构
[1] St Marys Univ, Fac Sport Hlth & Appl Sci, London, England
[2] Imperial Coll, London, England
关键词
peak torque; muscle recruitment; dynamometer; hip thrust; maximal strength; MANUAL MUSCLE TEST; HAND-HELD; GLUTEUS MAXIMUS; STRENGTH; TORQUE; KNEE; ACTIVATION; HAMSTRINGS; ARM;
D O I
10.1519/JSC.0000000000004012
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Goodwin, JE and Bull, AMJ. Novel assessment of isometric hip extensor function: reliability, joint angle sensitivity, and concurrent validity. J Strength Cond Res 36(10): 2762-2770, 2022-Closed-chain hip extension function has not been well examined. The aim of this study was to examine the reliability, joint angle sensitivity, muscle recruitment, and concurrent validity of a force plate-based isometric hip extensor test (isometric hip thrust). All subjects were active men aged 19-29 years. In part 1, bilateral and unilateral hip extensor testing was completed on 4 occasions by 14 subjects to evaluate repeatability of force and torque measures. In part 2, joint angle sensitivity of force, torque, and surface electromyography was assessed by 10 subjects completing testing at 4 hip joint angles in a single test session. In part 3, concurrent validity of joint torque was assessed relative to standing and supine test positions on an isokinetic dynamometer, by 10 subjects in a single test session. The repeatability study found small changes in the mean from sessions 1-2 (mean standardized change d = 0.31) and close to no change in later sessions (mean d = 0.12). Typical error was predominantly low to moderate (mean 0.42), and intraclass correlation coefficient (ICC) was typically high (mean ICC = 0.87). The joint angle sensitivity study showed that increasing the hip flexion resulted in increases in peak extension force (p = 0.001) and gluteus maximus activation (p = 0.003) and a reduction in biceps femoris activation (p < 0.001). There was no change in torque (p = 0.585) and vastus lateralis activation (p = 0.482). The concurrent validity study found that torque was correlated with supine dynamometry (R-2 = 0.555) but not with standing dynamometry (R-2 = 0.193). In summary, the isometric hip thrust is repeatable, but benefits from familiarization. Force output and muscle recruitment are sensitive to joint position, providing an opportunity to assess different functional output.
引用
收藏
页码:2762 / 2770
页数:9
相关论文
共 44 条
  • [31] Assessing the concurrent validity and reliability of an iPhone application for the measurement of range of motion and joint position sense in knee and ankle joints of young adults
    Romero-Franco, Natalia
    Jimenez-Reyes, Pedro
    Miguel Gonzalez-Hernandez, Jorge
    Carlos Fernandez-Dominguez, Juan
    PHYSICAL THERAPY IN SPORT, 2020, 44 : 136 - 142
  • [32] Reliability and concurrent validity of angle measurements in lower limb: EOS 3D goniometer versus 2D manual goniometer
    Huang, Jun
    Tian, Fanli
    Zhang, Zhigang
    Shi, Weidong
    Lin, Jun
    Chen, Liang
    Yang, Huilin
    JOURNAL OF ORTHOPAEDIC TRANSLATION, 2020, 24 : 96 - 102
  • [33] Touchscreen-based assessment of upper limb kinematics after stroke: Reliability, validity and sensitivity to motor impairment
    Goizueta, Sandra
    Dolores Navarro, Maria
    Calvo, Gabriela
    Campos, Gloria
    Colomer, Carolina
    Noe, Enrique
    Llorens, Roberto
    JOURNAL OF NEUROENGINEERING AND REHABILITATION, 2025, 22 (01)
  • [34] Gait assessment using the Microsoft Xbox One Kinect: Concurrent validity and inter-day reliability of spatiotemporal and kinematic variables
    Mentiplay, Benjamin F.
    Perraton, Luke G.
    Bower, Kelly J.
    Pua, Yong-Hao
    McGaw, Rebekah
    Heywood, Sophie
    Clark, Ross A.
    JOURNAL OF BIOMECHANICS, 2015, 48 (10) : 2166 - 2170
  • [35] Validity and Reliability of Wearable Motion Sensors for Clinical Assessment of Shoulder Function in Brachial Plexus Birth Injury
    Grip, Helena
    Kallstromer, Anna
    Ohberg, Fredrik
    SENSORS, 2022, 22 (23)
  • [36] Balance assessment under dual task conditions in patients with total knee arthroplasty: a test-retest reliability and concurrent validity study
    Ozcan, Damla
    Unver, Bayram
    Karatosun, Vasfi
    PHYSIOTHERAPY THEORY AND PRACTICE, 2025, 41 (01) : 93 - 98
  • [37] Feasibility, Validity, and Reliability of the Plank Isometric Hold as a Field-Based Assessment of Torso Muscular Endurance for Children 8-12 Years of Age
    Boyer, Charles
    Tremblay, Mark
    Saunders, Travis
    McFarlane, Allison
    Borghese, Michael
    Lloyd, Meghann
    Longmuir, Pat
    PEDIATRIC EXERCISE SCIENCE, 2013, 25 (03) : 407 - 422
  • [38] Test-retest reliability and concurrent validity assessment of a novel high-frequency sensor device for anterior tibial translation measurement in loaded and unloaded condition: an exploratory cross-sectional study
    Deiss, Valentin
    Bahler, Philippe
    Kolly, Pascal
    Scharer, Anton
    Henle, Philippe
    Eichelberger, Patric
    Lutz, Nathanael
    Baur, Heiner
    BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)
  • [39] Reliability and Validity of a Novel Trunk-Strength Assessment for High-Performance Sprint Flat-Water Kayakers
    Steeves, Darren
    Thornley, Leo J.
    Goreham, Joshua A.
    Jordan, Matthew J.
    Landry, Scott C.
    Fowles, Jonathon R.
    INTERNATIONAL JOURNAL OF SPORTS PHYSIOLOGY AND PERFORMANCE, 2019, 14 (04) : 486 - 492
  • [40] Reliability, Concurrent Validity, and Minimal Detectable Change of the Hand-Held Dynamometry for the Assessment of Knee Muscle Strength in Patients With Revision Total Knee Arthroplasty
    Eymir, Musa
    Unver, Bayram
    Karatosun, Vasfi
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2024, 105 (01): : 34 - 39