Retinal nerve fiber layer thickness in subgroups of multiple sclerosis, measured by optical coherence tomography and scanning laser polarimetry

被引:39
作者
Siepman, Theodora A. M. [1 ]
Bettink-Remeijer, Marijke Wefers [2 ]
Hintzen, Rogier Q. [1 ]
机构
[1] Erasmus MC, MS Ctr ErasMS, Dept Neurol, NL-3015 CE Rotterdam, Netherlands
[2] Rotterdam Eye Hosp, NL-3011 BH Rotterdam, Netherlands
关键词
Multiple sclerosis; Retinal nerve fiber layer; Optical coherence tomography; Scanning laser polarimetry; VARIABLE CORNEAL COMPENSATION; AXONAL LOSS; OUTCOME MEASURE; NEURITIS; DISABILITY; ATROPHY; GDX;
D O I
10.1007/s00415-010-5589-1
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Optical coherence tomography (OCT) and scanning laser polarimetry (GDx ECC) are non-invasive methods used to assess retinal nerve fiber layer (RNFL) thickness, which may be a reliable tool used to monitor axonal loss in multiple sclerosis (MS). The objectives of this study are (1) to compare OCT with the GDx ECC; (2) to assess and compare the RNFL thickness in subgroups of MS. Ophthalmologic examination and RNFL assessment by OCT and GDx were performed in 65 MS patients (26 relapsing-remitting (RRMS), ten secondary-progressive (SPMS), 29 primary-progressive (PPMS)). Twenty-eight patients (43%) had a history of optic neuritis (ON). Adjustments were made for age and disease duration. RNFL thickness was reduced in eyes with previous ON (p < 0.01). No differences were found between PPMS and relapse-onset MS. OCT and GDx ECC measurements were moderately correlated (rho = 0.73, p < 0.01). Visual field-mean deviation (MD) values correlated with OCT means (r = 0.44, p < 0.01) and GDx ECC TSNIT average (r = 0.41, p < 0.01). In patients without previous ON, EDSS correlated with MD (r = -0.36, p < 0.01), visual field-pattern standard deviation (PSD) (r = 0.30, p < 0.05), OCT means (r = -0.31-0.30, p < 0.05) and macular volume (r = -0.37, p < 0.01). For MSIS-29 physical impact score, significant correlations were found with MD (r = -0.48, p < 0.01) and PSD (r = 0.48, p < 0.01). Conclusions: No differences between PPMS and relapse-onset MS subgroups were found. RNFL thickness was reduced in eyes with previous ON. Although OCT and GDx ECC findings were moderately correlated and showed significant correlations with measures of visual function in patients without previous ON, EDSS correlated significantly with visual and OCT measures, but not with GDx ECC.
引用
收藏
页码:1654 / 1660
页数:7
相关论文
共 42 条
[1]   Optical coherence tomography measures axonal loss in multiple sclerosis independently of optic neuritis [J].
Albrecht, Philipp ;
Froehlich, Ruth ;
Hartung, Hans-Peter ;
Kieseier, Bernd C. ;
Methner, Axel .
JOURNAL OF NEUROLOGY, 2007, 254 (11) :1595-1596
[2]   Contrast letter acuity as a visual component for the Multiple Sclerosis Functional Composite [J].
Balcer, LJ ;
Baier, ML ;
Cohen, JA ;
Kooijmans, MF ;
Sandrock, AW ;
Nano-Schiavi, ML ;
Pfohl, DC ;
Mills, M ;
Bowen, J ;
Ford, C ;
Heidenreich, FR ;
Jacobs, DA ;
Markowitz, CE ;
Stuart, WH ;
Ying, GS ;
Galetta, SL ;
Maguire, MG ;
Cutter, GR .
NEUROLOGY, 2003, 61 (10) :1367-1373
[3]   Retinal nerve fibre layer imaging compared with histological measurements in a human eye [J].
Blumenthal, E. Z. ;
Parikh, R. S. ;
Pe'er, J. ;
Naik, M. ;
Kaliner, E. ;
Cohen, M. J. ;
Prabakaran, S. ;
Kogan, M. ;
Thomas, R. .
EYE, 2009, 23 (01) :171-175
[4]   Structure-function relationships using confocal scanning laser ophthalmoscopy, optical coherence tomography, and scanning laser polarimetry [J].
Bowd, Christopher ;
Zangwill, Linda M. ;
Medeiros, Felipe A. ;
Tavares, Ivan M. ;
Hoffmann, Esther M. ;
Bourne, Rupert R. ;
Sample, Pamela A. ;
Weinreb, Robert N. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2006, 47 (07) :2889-2895
[5]   Multiple sclerosis [J].
Compston, Alastair ;
Coles, Alasdair .
LANCET, 2008, 372 (9648) :1502-1517
[6]   Relapses and progression of disability in multiple sclerosis. [J].
Confavreux, C ;
Vukusic, S ;
Moreau, T ;
Adeleine, P .
NEW ENGLAND JOURNAL OF MEDICINE, 2000, 343 (20) :1430-1438
[7]   Tracking retinal nerve fiber layer loss after optic neuritis: a prospective study using optical coherence tomography [J].
Costello, F. ;
Hodge, W. ;
Pan, Y. I. ;
Eggenberger, E. ;
Coupland, S. ;
Kardon, R. H. .
MULTIPLE SCLEROSIS JOURNAL, 2008, 14 (07) :893-905
[8]   Quantifying tonal loss after optic neuritis with optical coherence tomography [J].
Costello, F ;
Coupland, S ;
Hodge, W ;
Lorello, GR ;
Koroluk, J ;
Pan, YI ;
Freedman, MS ;
Zackon, DH ;
Kardon, RH .
ANNALS OF NEUROLOGY, 2006, 59 (06) :963-969
[9]   MR correlates of cerebral atrophy in patients with multiple sclerosis [J].
De Stefano, N ;
Iannucci, G ;
Sormani, MP ;
Guidi, L ;
Bartolozzi, ML ;
Comi, G ;
Federico, A ;
Filippi, M .
JOURNAL OF NEUROLOGY, 2002, 249 (08) :1072-1077
[10]   Nerve fibre layer analysis with GDx with a variable corneal compensator in patients with multiple sclerosis [J].
Della Mea, Giovanni ;
Bacchetti, Sonia ;
Zeppieri, Marco ;
Brusini, Paolo ;
Cutuli, Daniela ;
Gigli, Gian Luigi .
OPHTHALMOLOGICA, 2007, 221 (03) :186-189