A multiwire proportional counter for XAS fluorescence experiments

被引:2
|
作者
Barrea, RA
Tamura, E
Tolentino, HCN
机构
[1] Lab Nacl Luz Sincrotron, BR-13083970 Campinas, SP, Brazil
[2] Univ Nacl Cordoba, Fac Matemat Astron & Fis, RA-5010 Cordoba, Argentina
关键词
multiwire proportional counters; x-ray detectors; diluted samples; fluorescence EXAFS;
D O I
10.1107/S0909049500014746
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A multiwire proportional counter was used in fluorescence X-ray absorption measurements and a comparison to a Si( Li) and NaI(Tl) detectors was done. The main features of the multiwire proportional counter are its high counting rate capability (10(7) counts.s(-1)) and large active area (6 x 6 cm(2)). It was shown that the MWPC is suitable for fluorescence absorption. Although the maximum capability was not reached in the present experiments, it was found that as the counting rate increase the MWPC performance became better than Si(Li) detectors and shows a similar response to the scintillator counter at medium counting rates (up to 10(5) counts.s(-1)).
引用
收藏
页码:381 / 383
页数:3
相关论文
共 50 条
  • [21] A MULTIWIRE PROPORTIONAL COUNTER FOR SELECTING STOPPAGE OF PARTICLES IN A THIN GAS TARGET
    KULYUKIN, MM
    PONTECOR.DB
    FALOMKIN, IV
    KHAZINS, DM
    SHCHERBA.YA
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1967, (02): : 326 - &
  • [22] INVESTIGATION OF DELTA-RAY PRODUCTION USING A MULTIWIRE PROPORTIONAL COUNTER
    BAILY, NA
    STEIGERWALT, JE
    RADIATION RESEARCH, 1975, 62 (03) : 562 - 562
  • [23] APPLICATION OF A MULTIWIRE PROPORTIONAL COUNTER TO THE MEASUREMENT OF BONE-MINERAL CONTENT
    HORSMAN, A
    PHYSICS IN MEDICINE AND BIOLOGY, 1981, 26 (01): : 184 - 185
  • [24] COMPUTATION OF POTENTIAL IN A MULTIWIRE PROPORTIONAL COUNTER OF ARBITRARY CROSS-SECTION
    SYMM, GT
    NUCLEAR INSTRUMENTS & METHODS, 1974, 118 (02): : 605 - 607
  • [25] A GAMMA-CAMERA FOR MEDICAL APPLICATIONS, USING A MULTIWIRE PROPORTIONAL COUNTER
    LACY, JL
    LEBLANC, AD
    BABICH, JW
    BUNGO, MW
    LATSON, LA
    LEWIS, RM
    POLINER, LR
    JONES, RH
    JOHNSON, PC
    JOURNAL OF NUCLEAR MEDICINE, 1984, 25 (09) : 1003 - 1012
  • [26] SOME CONSIDERATIONS IN USE OF A MULTIWIRE PROPORTIONAL COUNTER FOR ACQUISITION OF SECONDARY IONIZATION DATA
    BAILY, NA
    STEIGERWALT, JE
    RADIATION RESEARCH, 1976, 67 (03) : 614 - 614
  • [27] MULTIWIRE PROPORTIONAL COUNTER USED AS A POSITION-SENSITIVE DETECTOR FOR PROTEIN CRYSTALLOGRAPHY
    HAMLIN, R
    CORK, C
    NIELSEN, C
    VERNON, W
    XUONG, NH
    ACTA CRYSTALLOGRAPHICA SECTION A, 1975, 31 : S234 - S234
  • [28] Automatic method to manufacture 2D Multiwire Proportional Counter frames
    Martinez, J. C.
    Ramos-Lerate, I.
    Fernandez, F.
    Beltran, D.
    Bordas, J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 573 (1-2): : 41 - 43
  • [29] MULTIWIRE PROPORTIONAL COUNTER USED AS A POSITION-SENSITIVE DETECTOR FOR PROTEIN CRYSTALLOGRAPHY
    HAMLIN, R
    CORK, C
    NIELSEN, C
    VERNON, W
    XUONG, NH
    ACTA CRYSTALLOGRAPHICA SECTION A, 1978, 34 : S334 - S334
  • [30] MULTIWIRE PROPORTIONAL COUNTER TECHNIQUE FOR STANDARDIZATION OF LOW-ENERGY PHOTON SOURCES
    CHEW, WM
    MCGEORGE, JC
    FINK, RW
    NUCLEAR INSTRUMENTS & METHODS, 1973, 106 (03): : 499 - 501