A simple method for differentiating direct and indirect exposure to exhaled contaminants in mechanically ventilated rooms

被引:16
作者
Chen, Chun [1 ,2 ]
Zhao, Bin [3 ,4 ]
Lai, Dayi [5 ]
Liu, Wei [6 ]
机构
[1] Chinese Univ Hong Kong, Dept Mech & Automat Engn, Shatin 999077, Hong Kong, Peoples R China
[2] Chinese Univ Hong Kong, Shenzhen Res Inst, Shenzhen 518057, Peoples R China
[3] Tsinghua Univ, Sch Architecture, Dept Bldg Sci, Beijing 100084, Peoples R China
[4] Tsinghua Univ, Beijing Key Lab Indoor Air Qual Evaluat & Control, Beijing 100084, Peoples R China
[5] Tianjin Univ, Sch Environm Sci & Engn, Tianjin Key Lab Indoor Air Environm Qual Control, Tianjin 300072, Peoples R China
[6] Zhejiang Univ, ZJU UIUC, Sch Civil Engn, Haining 314400, Peoples R China
基金
中国国家自然科学基金;
关键词
ventilation; non-isothermal jet; particles; droplets; indoor environment; TRANSIENT PARTICLE-TRANSPORT; 2-BED HOSPITAL WARD; MARKOV-CHAIN MODEL; AIRBORNE TRANSMISSION; PERSONAL EXPOSURE; EXPIRATORY DROPLETS; INDOOR ENVIRONMENTS; INFECTIOUS AGENTS; AEROSOL TRANSPORT; CROSS-INFECTION;
D O I
10.1007/s12273-018-0441-0
中图分类号
O414.1 [热力学];
学科分类号
摘要
Many airborne infectious diseases can be transmitted via exhaled contaminants transported in the air. Direct exposure occurs when the exhaled jet from the infected person directly enters the breathing zone of the target person. Indirect exposure occurs when the contaminants disperse in the room and are inhaled by the target person. This paper presents a simple method for differentiating the direct and indirect exposure to exhaled contaminants in mechanically ventilated rooms. Experimental data for 191 cases were collected from the literature. After analyzing the data, a simple method was developed to differentiate direct and indirect exposure in mixing and displacement ventilated rooms. The proposed method correctly differentiated direct and indirect exposure for 120 out of the 133 mixing ventilation cases and 47 out of the 58 displacement ventilation cases. Therefore, the proposed method is suitable for use at the early design stage to quickly assess whether there will be direct exposure to exhaled contaminants in a mechanically ventilated room.
引用
收藏
页码:1039 / 1051
页数:13
相关论文
共 52 条
[1]  
BATURIN VV, 1972, FUNDAMENTALS IND VEN, P79
[2]   Experimental analysis of the air velocity and contaminant dispersion of human exhalation flows [J].
Berlanga, F. A. ;
Olmedo, I. ;
Ruiz de Adana, M. .
INDOOR AIR, 2017, 27 (04) :803-815
[3]   Dispersal of exhaled air and personal exposure in displacement ventilated rooms [J].
Bjorn, E ;
Nielsen, PV .
INDOOR AIR, 2002, 12 (03) :147-164
[4]  
BLOCH AB, 1985, PEDIATRICS, V75, P676
[5]  
Bocksell T, 1998, ENHANCED DRW MODEL T
[6]   Protected zone ventilation and reduced personal exposure to airborne cross-infection [J].
Cao, G. ;
Nielsen, P. V. ;
Jensen, R. L. ;
Heiselberg, P. ;
Liu, L. ;
Heikkinen, J. .
INDOOR AIR, 2015, 25 (03) :307-319
[7]   Characterization of expiration air jets and droplet size distributions immediately at the mouth opening [J].
Chao, C. Y. H. ;
Wan, M. P. ;
Morawska, L. ;
Johnson, G. R. ;
Ristovski, Z. D. ;
Hargreaves, M. ;
Mengersen, K. ;
Corbett, S. ;
Li, Y. ;
Xie, X. ;
Katoshevski, D. .
JOURNAL OF AEROSOL SCIENCE, 2009, 40 (02) :122-133
[8]   Simplified models for exhaled airflow from a cough with the mouth covered [J].
Chen, C. ;
Lin, C. -H. ;
Jiang, Z. ;
Chen, Q. .
INDOOR AIR, 2014, 24 (06) :580-591
[9]   Some questions on dispersion of human exhaled droplets in ventilation room: answers from numerical investigation [J].
Chen, C. ;
Zhao, B. .
INDOOR AIR, 2010, 20 (02) :95-111
[10]   Comparing the Markov Chain Model with the Eulerian and Lagrangian Models for Indoor Transient Particle Transport Simulations [J].
Chen, Chun ;
Liu, Wei ;
Lin, Chao-Hsin ;
Chen, Qingyan .
AEROSOL SCIENCE AND TECHNOLOGY, 2015, 49 (10) :857-871