Sound-Speed Image Reconstruction in Sparse-Aperture 3-D Ultrasound Transmission Tomography

被引:59
作者
Jirik, Radovan [1 ]
Peterlik, Igor [1 ]
Ruiter, Nicole [2 ]
Fousek, Jan [1 ]
Dapp, Robin [2 ]
Zapf, Michael [2 ]
Jan, Jiri [1 ]
机构
[1] Brno Univ Technol, Dept Biomed Engn, Brno, Czech Republic
[2] Karlsruhe Inst Technol, Inst Data Proc & Elect, Eggenstein, Germany
关键词
INCONSISTENT; TISSUE;
D O I
10.1109/TUFFC.2012.2185
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The paper is focused on sound-speed image reconstruction in 3-D ultrasound transmission tomography. Along with ultrasound reflectivity and the attenuation coefficient, sound speed is an important parameter which is related to the type and pathological state of the imaged tissue. This is important in the intended application, breast cancer diagnosis. In contrast to 2-D ultrasound transmission tomography systems, a 3-D system can provide an isotropic spatial resolution in the x-, y-, and z-directions in reconstructed 3-D images of ultrasound parameters. Several challenges must, however, be addressed for 3-D systems-namely, a sparse transducer distribution, low signal-to-noise ratio, and higher computational complexity. These issues are addressed in terms of sound-speed image reconstruction, using edge-preserving regularized algebraic reconstruction in combination with synthetic aperture focusing. The critical points of the implementation are also discussed, because they are crucial to enable a complete 3-D image reconstruction. The methods were tested on a synthetic data set and on data sets measured with the Karlsruhe 3-D ultrasound computer tomography (USCT) I prototype using phantoms. The sound-speed estimates in the reconstructed volumes agreed with the reference values. The breast-phantom outlines and the lesion-mimicking objects were also detectable in the resulting sound-speed volumes.
引用
收藏
页码:254 / 264
页数:11
相关论文
共 34 条
[1]  
Andre MP, 1997, INT J IMAG SYST TECH, V8, P1
[2]   MIT image reconstruction based on edge-preserving regularization [J].
Casanova, R ;
Silva, A ;
Borges, AR .
PHYSIOLOGICAL MEASUREMENT, 2004, 25 (01) :195-207
[3]   Deterministic edge-preserving regularization in computed imaging [J].
Charbonnier, P ;
BlancFeraud, L ;
Aubert, G ;
Barlaud, M .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 1997, 6 (02) :298-311
[4]  
Duck F., 1998, MED SCI SERIES
[5]   Development of ultrasound tomography for breast imaging: Technical assessment [J].
Duric, N ;
Littrup, P ;
Babkin, A ;
Chambers, D ;
Azevedo, S ;
Kalinin, A ;
Pevzner, R ;
Tokarev, M ;
Holsapple, E ;
Rama, O ;
Duncan, R .
MEDICAL PHYSICS, 2005, 32 (05) :1375-1386
[6]   Detection of breast cancer with ultrasound tomography: First results with the Computed Ultrasound Risk Evaluation (CURE) prototype [J].
Duric, Nebojsa ;
Littrup, Peter ;
Poulo, Lou ;
Babkin, Alex ;
Pevzner, Roman ;
Holsapple, Earle ;
Rama, Olsi ;
Glide, Carri .
MEDICAL PHYSICS, 2007, 34 (02) :773-785
[7]   NONLINEAR IMAGE RECOVERY WITH HALF-QUADRATIC REGULARIZATION [J].
GEMAN, D ;
YANG, CD .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 1995, 4 (07) :932-946
[8]   3D ultrasound computer tomography for medical imaging [J].
Gemmeke, H. ;
Ruiter, N. V. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (02) :1057-1065
[9]  
Gemmeke H., 2010, IEEE NUCL SCI S REC, P2449
[10]   RECONSTRUCTION OF ULTRASOUND PROPAGATION SPEED DISTRIBUTIONS IN SOFT-TISSUE - TIME-OF-FLIGHT TOMOGRAPHY [J].
GLOVER, GH ;
SHARP, JC .
IEEE TRANSACTIONS ON SONICS AND ULTRASONICS, 1977, 24 (04) :229-234