Biomechanical Evaluation of Sagittal Split Ramus Osteotomy Fixation Techniques in Mandibular Setback

被引:3
作者
Chen, Michael Y. C. [1 ,2 ]
Wu, Yi-Fan [1 ,2 ]
Huang, Heng-Li [1 ,3 ]
Hsu, Jui-Ting [1 ,3 ]
机构
[1] China Med Univ, Sch Dent, Taichung 404, Taiwan
[2] China Med Univ & Hosp, Dept Dent, Taichung 404, Taiwan
[3] Asia Univ, Dept Bioinformat & Med Engn, Taichung 413, Taiwan
来源
APPLIED SCIENCES-BASEL | 2020年 / 10卷 / 09期
关键词
sagittal split ramus osteotomy; fixation; bone plate; screw; RIGID INTERNAL-FIXATION; IN-VITRO EVALUATION; BICORTICAL SCREWS; STABILITY; SURGERY;
D O I
10.3390/app10093031
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The objective of this study was to evaluate and compare the biomechanical behavior of internal fixation techniques in bilateral sagittal split ramus osteotomies (BSSROs) for mandibular setback. Artificial polyurethane mandibles were used in this study. The distal segment of the mandible was repositioned in an 8-mm setback position. All mandibles were divided into three groups: Group 1 had a straight plate with a four-hole monocortical fixation, Group 2 had a curved plate with a four-hole monocortical fixation, and Group 3 had a three-inverted L-type bicortical screw fixation. Vertical loads were applied on the incisal edge by a material testing system. The resistance force at 1, 3, 5, and 10 mm of displacement was analyzed. From the experimental results, Group 1 showed significantly lower results than Groups 2 and 3. No significant difference was observed between Groups 2 and 3 at 1, 3, and 5 mm of displacement. However, at 10 mm of displacement, the resistance force of Group 3 was greater than that of Group 2. For BSSROs, this study concluded that curved plate fixation exhibited the same rigidity as the inverted-L bicortical screw fixation did at <= 5 mm displacement.
引用
收藏
页数:7
相关论文
共 29 条
[1]   Neurosensory disturbance after sagittal split and intraoral vertical ramus osteotomy: as reported in questionnaires and patients' records [J].
Al-Bishri, A ;
Barghash, Z ;
Rosenquist, J ;
Sunzel, B .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2005, 34 (03) :247-251
[2]   An In Vitro Evaluation of Rigid Internal Fixation Techniques for Sagittal Split Ramus Osteotomies: Setback Surgery [J].
Brasileiro, Bernardo Ferreira ;
Grotta-Grempel, Rafael ;
Bovi Ambrosano, Glaucia Maria ;
Passeri, Luis Augusto .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2012, 70 (04) :941-951
[3]   An in Vitro Evaluation of Rigid internal Fixation Techniques for Sagittal Split Ramus Osteotomies: Advancement Surgery [J].
Brasileiro, Bernardo Ferreira ;
Grempel, Rafael Grotta ;
Bovi Ambrosano, Glaucia Maria ;
Passeri, Luis Augusto .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2009, 67 (04) :809-817
[4]   Substitutes for human cadaveric hone in maxillofacial rigid fixation research [J].
Bredbenner, TL ;
Haug, RH .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2000, 90 (05) :574-580
[5]   New fixation approach for transverse metacarpal neck fracture: a biomechanical study [J].
Chiu, Yung-Cheng ;
Tsai, Ming-Tzu ;
Hsu, Cheng-En ;
Hsu, Horng-Chaung ;
Huang, Heng-Li ;
Hsu, Jui-Ting .
JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2018, 13
[6]   Biomechanical in vitro evaluation of three stable internal fixation techniques used in sagittal osteotomy of the mandibular ramus: a study in sheep mandibles [J].
de Olivera, Leandro Benetti ;
Sant'Ana, Eduardo ;
Manzato, Antonio Jose ;
Bunemer Guerra, Fabio Luis ;
Arnett, G. William .
JOURNAL OF APPLIED ORAL SCIENCE, 2012, 20 (04) :419-426
[7]   Comparison of stability of absorbable and titanium plate and screw fixation for sagittal split ramus osteotomy [J].
Dolanmaz, D ;
Uckan, S ;
Isik, K ;
Saglam, H .
BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2004, 42 (02) :127-132
[8]   Mandibular setback by sagittal split ramus osteotomy: A 12-year follow-up [J].
Eggensperger, N ;
Raditsch, T ;
Taghizadeh, F ;
Iizuka, T .
ACTA ODONTOLOGICA SCANDINAVICA, 2005, 63 (03) :183-188
[9]   Composite Bone Models in Orthopaedic Surgery Research and Education [J].
Elfar, John J. ;
Menorca, Ron Martin Garcia ;
Reed, Jeffrey Douglas ;
Stanbury, Spencer .
JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2014, 22 (02) :111-120
[10]   Stability of osteosynthesis with bicortical screws placed in a triangular shape in mandibular sagittal split 5 mm advancement osteotomy: Biomechanical tests [J].
Hadi, Geha ;
Karine, Bruyere-Garnier ;
Yves, Caire ;
Pierre, Lapelerie .
BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2010, 48 (08) :624-628