Electrodialysis and nanofiltration of surface water for subsequent use as infiltration water

被引:34
作者
Van der Bruggen, B
Milis, R
Vandecasteele, C
Bielen, P
Van San, E
Huysman, K
机构
[1] Katholieke Univ Leuven, Dept Chem Engn, Lab Environm Technol, B-3001 Heverlee, Belgium
[2] Pidpa Water Prod, Purificat & Pilot Plant Dept, B-2018 Antwerp, Belgium
关键词
electrodialysis; nanofiltration; membrane treatment; surface water; groundwater recharge;
D O I
10.1016/S0043-1354(03)00296-3
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In order to achieve stable groundwater levels, an equilibrium between the use of groundwater for drinking water production and natural or artificial groundwater recharge by infiltration is needed. Local governments usually require that the composition of the water used for artificial recharge is similar to the surface water that is naturally present in the specific recharge area. In this paper, electrodialysis (ED) and nanofiltration were evaluated as possible treatment technologies for surface water from a canal in Flanders, the North of Belgium, in view of infiltration at critical places on heathlands. Both methods were evaluated on the basis of a comparison between the water composition after treatment and the composition of local surface waters. The treatment generally consists of a tuning of pH and the removal of contaminants originating from industrial and agricultural activity, e.g., nitrates and pesticides. Further evaluation of the influence of the composition of the water on the characteristics of the artificial recharge, however, was not envisaged. In a case study of water from the canal Schoten-Dessel, satisfactory concentration reductions of Cl-, SO42-, NO3-, HCO3-, Na+, Mg2+, K+ and Ca2+ were obtained by ultrafiltration pretreatment followed by ED. Nanofiltration with UTC-20, N30F, Desal 51 HL, UTC-60 and Desal 5 DL membranes resulted in an insufficient removal level, especially for the monovalent ions. (C) 2003 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3867 / 3874
页数:8
相关论文
共 26 条
[1]  
Bouwer H, 2000, J ENVIRON HEALTH, V63, P17
[2]   Artificial recharge of groundwater: hydrogeology and engineering [J].
Bouwer, H .
HYDROGEOLOGY JOURNAL, 2002, 10 (01) :121-142
[3]   Comparison of models for estimation of groundwater recharge, using data from a deep weighing lysimeter [J].
Chapman, TG ;
Malone, RW .
MATHEMATICS AND COMPUTERS IN SIMULATION, 2002, 59 (1-3) :3-17
[4]   HACCP (Hazard Analysis and Critical Control Points) to guarantee safe water reuse and drinking water production - a case study [J].
Dewettinck, T ;
Van Houtte, E ;
Geenens, D ;
Van Hege, K ;
Verstraete, W .
WATER SCIENCE AND TECHNOLOGY, 2001, 43 (12) :31-38
[5]   Occurrence of iodinated X-ray contrast media in domestic effluents and their fate during indirect potable reuse [J].
Drewes, JE ;
Fox, P ;
Jekel, M .
JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING, 2001, 36 (09) :1633-1645
[6]   Identification of wastewater dissolved organic carbon characteristics in reclaimed wastewater and recharged groundwater [J].
Fujita, Y ;
Ding, WH ;
Reinhard, M .
WATER ENVIRONMENT RESEARCH, 1996, 68 (05) :867-876
[7]   Tracking persistent pharmaceutical residues from municipal sewage to drinking water [J].
Heberer, T .
JOURNAL OF HYDROLOGY, 2002, 266 (3-4) :175-189
[8]   Geochemical transformations during artificial groundwater recharge: Soil-water interactions of inorganic constituents [J].
Johnson, JS ;
Baker, LA ;
Fox, P .
WATER RESEARCH, 1999, 33 (01) :196-206
[9]  
Kanarek A, 1996, WATER SCI TECHNOL, V34, P227, DOI 10.1016/S0273-1223(96)00842-6
[10]   Removal of organics from aqueous solutions by commercial RO and NF membranes of characterized porosities [J].
Kosutic, K ;
Kunst, B .
DESALINATION, 2002, 142 (01) :47-56