Femtosecond Laser-Assisted Cataract Surgery with Integrated Optical Coherence Tomography

被引:206
作者
Palanker, Daniel V. [1 ]
Blumenkranz, Mark S. [1 ]
Andersen, Dan [2 ]
Wiltberger, Michael [2 ]
Marcellino, George [2 ]
Gooding, Phillip [2 ]
Angeley, David [2 ]
Schuele, Georg [2 ]
Woodley, Bruce [2 ]
Simoneau, Michael [2 ]
Friedman, Neil J. [1 ]
Seibel, Barry [3 ]
Batlle, Juan [4 ]
Feliz, Rafael [4 ]
Talamo, Jonathan [5 ]
Culbertson, William [6 ]
机构
[1] Stanford Univ, Dept Ophthalmol, Stanford, CA 94305 USA
[2] OptiMedica Corp, Santa Clara, CA 95054 USA
[3] Seibel Vis Surg, Los Angeles, CA 90025 USA
[4] Ctr Laser, Santo Domingo, Dominican Rep
[5] Talamo Laser Eye Consultants, Waltham, MA 02451 USA
[6] Bascom Palmer Eye Inst, Miami, FL 33136 USA
关键词
ACCOMMODATING INTRAOCULAR-LENS; ELECTRON AVALANCHE KNIFE; CAPSULORHEXIS SIZE; CAPSULOTOMY; OPACIFICATION; DECENTRATION; FIXATION; BLADE;
D O I
10.1126/scitranslmed.3001305
中图分类号
Q2 [细胞生物学];
学科分类号
071009 ; 090102 ;
摘要
About one-third of people in the developed world will undergo cataract surgery in their lifetime. Although marked improvements in surgical technique have occurred since the development of the current approach to lens replacement in the late 1960s and early 1970s, some critical steps of the procedure can still only be executed with limited precision. Current practice requires manual formation of an opening in the anterior lens capsule, fragmentation and evacuation of the lens tissue with an ultrasound probe, and implantation of a plastic intraocular lens into the remaining capsular bag. The size, shape, and position of the anterior capsular opening (one of the most critical steps in the procedure) are controlled by freehand pulling and tearing of the capsular tissue. Here, we report a technique that improves the precision and reproducibility of cataract surgery by performing anterior capsulotomy, lens segmentation, and corneal incisions with a femtosecond laser. The placement of the cuts was determined by imaging the anterior segment of the eye with integrated optical coherence tomography. Femtosecond laser produced continuous anterior capsular incisions, which were twice as strong and more than five times as precise in size and shape than manual capsulorhexis. Lens segmentation and softening simplified its emulsification and removal, decreasing the perceived cataract hardness by two grades. Three-dimensional cutting of the cornea guided by diagnostic imaging creates multiplanar self-sealing incisions and allows exact placement of the limbal relaxing incisions, potentially increasing the safety and performance of cataract surgery.
引用
收藏
页数:9
相关论文
共 41 条
[1]   Risk factors for and management of dropped nucleus during phacoemulsification [J].
Aasuri, MK ;
Kompella, VB ;
Majji, AB .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (09) :1428-1432
[2]  
ALIO JL, 2009, INCISIONS MAXIMIZING
[3]  
ASSIA EI, 1991, OPHTHALMOLOGY, V98, P432
[4]   THE ELASTIC PROPERTIES OF THE LENS CAPSULE IN CAPSULORHEXIS [J].
ASSIA, EI ;
APPLE, DJ ;
TSAI, JC ;
LIM, ES .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1991, 111 (05) :628-632
[5]   Intacs for keratoconus and Post-LASIK ectasia - Mechanical versus femtosecond laser-assisted channel creation [J].
Carrasquillo, Karen G. ;
Rand, Janet ;
Talamo, Jonathan H. .
CORNEA, 2007, 26 (08) :956-962
[6]  
Çekiç O, 1999, OPHTHALMIC SURG LAS, V30, P185
[7]   Maximum permissible exposures for ocular safety (ANSI 2000), with emphasis on ophthalmic devices [J].
Delori, Francois C. ;
Webb, Robert H. ;
Sliney, David H. .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2007, 24 (05) :1250-1265
[8]   Subjective difficulty of each stage of phacoemulsification cataract surgery performed by basic surgical trainees [J].
Dooley, IJ ;
O'Brien, PD .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (04) :604-608
[10]   Phacoemulsification conditions resulting in thermal wound injury [J].
Ernest, P ;
Rhem, M ;
McDermott, M ;
Lavery, K ;
Sensoli, A .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2001, 27 (11) :1829-1839