The energy gain reduction due to shadow inside a flat-plate solar collector

被引:21
作者
Farhadi, Rouhollah [1 ]
Taki, Morteza [1 ]
机构
[1] Agr Sci & Nat Resources Univ Khuzestan, Dept Agr Machinery & Mechanizat, Mollasani 6341773637, Iran
关键词
Shade; Shadow ratio; Energy gain; Solar collector; HOURLY DIFFUSE FRACTION; HEAT-LOSS COEFFICIENT; DAILY SHADING FACTOR; SAO-PAULO; RADIATION; IRRADIATION; PERFORMANCE; ABSORBER; COOKER; DESIGN;
D O I
10.1016/j.renene.2019.09.012
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Shadow on the absorber plate of a flat-plate solar collector or a solar cooker box can reduce absorbed energy. The main goal of this research is to investigate the effective factors on the shadow formation inside a solar collector. In addition, the energy gain reduction due to shadow was calculated. The length, width (0.5-2.5) and height (0.01-0.2 m) of a solar collector, tilt angle (0.01-80 degrees) and latitude (0.01-65 degrees) were considered as the effective variables on the shadow formation. The sum of shadow ratio and the percentage of energy gain reduction per year were chosen as the dependent variables, and the effect of each factor was discussed. Results showed that the effective variables (strong to weak) were height, width, tilt angle, latitude and length for the sum of shadow ratio per year, and height, tilt angle, width, latitude and length for the energy gain reduction per year. The minimum and maximum energy gain reduction per year due to shadow for a solar collector with length = width =1 and height = 0.04 m were obtained 5.23 and 21.64%, respectively. If a solar collector has a rectangular plate, the larger width is more suitable than the larger length for the shadow reduction. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:730 / 740
页数:11
相关论文
共 36 条
[1]   Optimum slope angles and the corresponding uncertainties for a solar collector [J].
Abdolzadeh, Z. ;
Abdolzadeh, M. ;
Fadaeinedjad, R. .
INTERNATIONAL JOURNAL OF AMBIENT ENERGY, 2016, 37 (01) :46-54
[2]   Computation of glass-cover temperatures and top heat loss coefficient of flat-plate solar collectors with double glazing [J].
Akhtar, N. ;
Mullick, S. C. .
ENERGY, 2007, 32 (07) :1067-1074
[3]  
Ali BSM, 2000, RENEW ENERG, V21, P573, DOI 10.1016/S0960-1481(00)00089-6
[4]  
[Anonymous], 1991, SOLAR ENG THERMAL PR, DOI DOI 10.1002/9781118671603.FMATTER
[5]  
Boland J, 2001, ENVIRONMETRICS, V12, P103, DOI 10.1002/1099-095X(200103)12:2<103::AID-ENV447>3.0.CO
[6]  
2-2
[7]   MODELING THE SOLAR IRRADIATION ON FLAT-PLATE COLLECTORS AUGMENTED WITH PLANAR REFLECTORS [J].
BOLLENTIN, JW ;
WILK, RD .
SOLAR ENERGY, 1995, 55 (05) :343-354
[8]   HOURLY DIFFUSE FRACTION CORRELATION AT A TROPICAL LOCATION [J].
CHANDRASEKARAN, J ;
KUMAR, S .
SOLAR ENERGY, 1994, 53 (06) :505-510
[9]   Diffuse solar irradiation model evaluation in the North Mediterranean belt area [J].
De Miguel, A ;
Bilbao, J ;
Aguiar, R ;
Kambezidis, H ;
Negro, E .
SOLAR ENERGY, 2001, 70 (02) :143-153
[10]   Accurate analytical modeling of flat plate solar collectors: Extended correlation for convective heat loss across the air gap between absorber and cover plate [J].
Eismann, Ralph .
SOLAR ENERGY, 2015, 122 :1214-1224