Determination of optical purity by nonenantioselective LC using CD detection

被引:21
作者
Bossu, E [1 ]
Cotichini, V [1 ]
Gostoli, G [1 ]
Farina, A [1 ]
机构
[1] Ist Super Sanita, Lab Chim Farmaco, I-00161 Rome, Italy
关键词
anisotropy factor (g); chiroptical detector; circular dichroism (CD); enantiomeric purity (e.p.); HPLC;
D O I
10.1016/S0731-7085(01)00483-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The use of a circular dichroism (CD) based HPLC detection system was recently described by some authors and proposed for a nonenantioselective HPLC enantiomeric purity determination. Indeed the system, measuring both CD and UV signals simultaneously, allows the evaluation of the g anisotropy factor. In order to experimentally support such an analytical procedure as an alternative to the enantioselective chromatographic method currently found in some pharmacopocial monographs, we have studied its application to the analysis of dexchlorpheniramine maleate, an active substance which exhibits a poor CD signal in the 250-270 nm spectral region with a g value of the order of 10(-4). The results reported indicate that the suitability of the studied procedure for the enantiomeric purity determination is obtained only when the CD-detector reaches high stability, indeed a certain time lag is systematically necessary to obtain stable responses, i.e. adequate precision. The enantioselective HPLC procedure seems to be more precise for enantiomeric purity values less than or equal to2% than the CD based detection system; such a disadvantage might be counterbalanced by the use of non chiral stationary phases. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:837 / 848
页数:12
相关论文
共 14 条
[1]  
[Anonymous], CPMPICH28195
[2]   DETERMINATION OF OPTICAL PURITY BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY UPON NONCHIRAL STATIONARY PHASES WITH DUAL CIRCULAR DICHROISM/ABSORPTION DETECTION [J].
BERTUCCI, C ;
SALVADORI, P ;
GUIMARAES, LFL .
JOURNAL OF CHROMATOGRAPHY A, 1994, 666 (1-2) :535-539
[3]   CIRCULAR-DICHROISM DETECTION IN HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY - EVALUATION OF THE ANISOTROPY FACTOR [J].
BERTUCCI, C ;
DOMENICI, E ;
SALVADORI, P .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1990, 8 (8-12) :843-846
[4]  
Bertucci C, 2000, CHIRALITY, V12, P84, DOI 10.1002/(SICI)1520-636X(2000)12:2<84::AID-CHIR5>3.0.CO
[5]  
2-G
[6]  
*EUR PHARM, 1999, TECHN GUID EL MON
[7]  
*EUR PHARM, 2001, MON S, V1196, P709
[8]  
Gergely A., 1994, ANAL APPL CIRCULAR D, P279
[9]  
Hadley MR, 2000, ENANTIOMER, V5, P357
[10]   Determination of enantiomeric purity by simultaneous dual circular dichroism and ultraviolet spectroscopy [J].
Horvath, P ;
Gergely, A ;
Noszal, B .
TALANTA, 1997, 44 (08) :1479-1485