Ultrasound-guided peripheral nerve blockade of the upper extremity

被引:27
作者
Koscielniak-Nielsen, Zbigniew J. [1 ]
Dahl, Jorgen B. [1 ]
机构
[1] Rigshosp, HOC, Dept Anaesthesiol, DK-2100 Copenhagen, Denmark
关键词
brachial plexus; complications; nerve block; regional anesthesia; ultrasound guidance; upper extremity; AXILLARY BRACHIAL-PLEXUS; MINIMUM EFFECTIVE VOLUME; LOCAL-ANESTHETIC SPREAD; INTERSCALENE BLOCK; ELECTRICAL-STIMULATION; DOUBLE-BLIND; INJECTION; ANALGESIA; GUIDANCE; PAIN;
D O I
10.1097/ACO.0b013e32835069c2
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Purpose of review Is ultrasound guidance changing the practice of upper extremity regional anesthesia? This review will aim to describe the findings published in the literature during the previous 18 months. Recent findings In some approaches to brachial plexus blockade, local anesthetic volumes may be reduced without deterioration of analgesic effect. However, even 10 ml of local injected into the interscalene space may result in diaphragmatic paresis. High-resolution ultrasonography has revealed anatomical variations of C5, C6 and C7 nerve roots in almost half of the patients examined, without negative block effectiveness. The addition of dexamethasone may prolong analgesia after single-shot interscalene and supraclavicular blocks. Insertion of brachial plexus perineural catheters using ultrasound guidance can be successful and provides better postoperative analgesia than single-shot blocks for up to 24 h postoperatively. Infraclavicular catheters provide superior analgesia when compared with supraclavicular catheters. Multiple-site injections of local offer no advantage over a single-site injection during an infraclavicular block. Ultrasound guidance compared with neurostimulation may reduce patient discomfort during axillary blocks compared with neurostimulation. Intra-epineural injections are common during an interscalene blockade, but the incidence of neurological injury remains low. There is an ongoing debate on the effectiveness and safety of ultrasound-guided intra-epineurial injections. Summary Current literature suggests a reduction of the volume of local anesthetics used for ultrasound-guided upper extremity blockades. Dexamethasone may prolong duration of brachial plexus blocks and more frequent use of perineural catheters is encouraged. Controversy over intra-epineurial injections exists and requires additional large-scale studies.
引用
收藏
页码:253 / 259
页数:7
相关论文
共 44 条
[1]   Role of local anesthetic spread pattern and electrical stimulation in ultrasound-guided musculocutaneous nerve block [J].
Al-Nasser, Bassam ;
Hubert, Christophe ;
Negre, Michele .
JOURNAL OF CLINICAL ANESTHESIA, 2010, 22 (05) :334-339
[2]   Extraneural versus Intraneural Stimulation Thresholds during Ultrasound-guided Supraclavicular Block [J].
Bigeleisen, Paul E. ;
Moayeri, Nizar ;
Groen, Gerbrand J. .
ANESTHESIOLOGY, 2009, 110 (06) :1235-1243
[3]   Comfort of the patient during axillary blocks placement: a randomized comparison of the neurostimulation and the ultrasound guidance techniques [J].
Bloc, Sebastien ;
Mercadal, Luc ;
Garnier, Thierry ;
Komly, Bernard ;
Leclerc, Pascal ;
Morel, Bertrand ;
Ecoffey, Claude ;
Dhonneur, Gilles .
EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2010, 27 (07) :628-633
[4]   Ultrasound-guided continuous suprascapular nerve block for adhesive capsulitis: one case and a short topical review [J].
Borglum, J. ;
Bartholdy, A. ;
Hautopp, H. ;
Krogsgaard, M. R. ;
Jensen, K. .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2011, 55 (02) :242-247
[5]   Selective Local Anesthetic Placement Using Ultrasound Guidance and Neurostimulation for Infraclavicular Brachial Plexus Block [J].
Bowens, Clifford, Jr. ;
Gupta, Rajnish K. ;
O'Byrne, William T. ;
Schildcrout, Jonathan S. ;
Shi, Yaping ;
Hawkins, Jermel J. ;
Michaels, Damon R. ;
Berry, James M. .
ANESTHESIA AND ANALGESIA, 2010, 110 (05) :1480-1485
[6]   Functional Deficits After Intraneural Injection During Interscalene Block [J].
Cohen, Joshua M. ;
Gray, Andrew T. .
REGIONAL ANESTHESIA AND PAIN MEDICINE, 2010, 35 (04) :397-399
[7]  
de Jong R., 1994, LOCAL ANESTHETICS
[8]  
Dooley J, 2010, CAN J ANESTH, V57, P936, DOI 10.1007/s12630-010-9360-y
[9]   An Ultrasonographic Assessment of Nerve Stimulation-Guided Median Nerve Block at the Elbow: A Local Anesthetic Spread, Nerve Size, and Clinical Efficacy Study [J].
Dufour, Eric ;
Cymerman, Alexandre ;
Nourry, Gerard ;
Balland, Nicolas ;
Couturier, Christian ;
Liu, Ngai ;
Dreyfus, Jean-Francois ;
Fischler, Marc .
ANESTHESIA AND ANALGESIA, 2010, 111 (02) :561-567
[10]   Minimum Effective Volume of Local Anesthetic for Ultrasound-Guided Supraclavicular Brachial Plexus Block [J].
Duggan, Edel ;
El Beheiry, Hossam ;
Perlas, Anahi ;
Lupu, Mario ;
Nuica, Alina ;
Chan, Vincent W. S. ;
Brull, Richard .
REGIONAL ANESTHESIA AND PAIN MEDICINE, 2009, 34 (03) :215-218