Long-Term Efficacy and Safety of Paclitaxel-Eluting Balloon for the Treatment of Drug-Eluting Stent Restenosis 3-Year Results of a Randomized Controlled Trial

被引:89
作者
Kufner, Sebastian [1 ]
Cassese, Salvatore [1 ]
Valeskini, Marco [1 ]
Neumann, Franz-Josef [2 ]
Schulz-Schuepke, Stefanie [1 ,3 ]
Hoppmann, Petra [4 ]
Fusaro, Massimiliano [1 ]
Schunkert, Heribert [1 ,3 ]
Laugwitz, Karl-Ludwig [3 ,4 ]
Kastrati, Adnan [1 ,3 ]
Byrne, Robert A. [1 ]
机构
[1] Tech Univ Munich, Klin Herz & Kreislauferkrankungen, Deutsch Herzzentrum Munchen, D-80636 Munich, Germany
[2] Univ Herzzentrum Freiburg Bad Krozingen, Klin Kardiol & Angiol 2, Freiburg, Krozingen, Germany
[3] DZHK German Ctr Cardiovasc Res, Munich, Germany
[4] Tech Univ Munich, Med Klin 1, Klinikum Rechts Isar, D-80636 Munich, Germany
关键词
balloon angioplasty; drug-eluting stent restenosis; paclitaxel-eluting balloon; paclitaxel-eluting stent; ISAR-DESIRE; BARE-METAL; ANGIOPLASTY; IMPLANTATION; METAANALYSIS; ANGIOGRAPHY; INSIGHTS;
D O I
10.1016/j.jcin.2015.01.031
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES This study sought to investigate the long-term comparative efficacy and safety of paclitaxel-eluting balloon (PEB), paclitaxel-eluting stent (PES), or balloon angioplasty (BA) for the treatment of drug-eluting stent restenosis. BACKGROUND The optimal treatment of drug-eluting stent restenosis remains unknown. Although PEB has shown encouraging results, the long-term clinical efficacy and safety of PEB remains poorly defined. METHODS A total of 402 patients with clinically significant restenosis in limus-eluting stents were randomly assigned to receive PEB (n = 137), PES (n = 131), or BA (n = 134). For this analysis, PEB versus PES and PEB versus BA were compared. The primary efficacy and safety endpoints were target lesion revascularization and the composite of death or myocardial infarction. RESULTS At a median follow-up of 3 years, the risk of target lesion revascularization was comparable with PEB versus PES (hazard ratio [HR]: 1.46, 95% confidence interval [CI]: 0.91 to 2.33; p = 0.11) and lower with PEB versus BA (HR: 0.51, 95% CI: 0.34 to 0.74; p < 0.001). The risk of death/myocardial infarction tended to be lower with PEB versus PES (HR: 0.55, 95% CI: 0.28 to 1.07; p = 0.08), due to a lower risk of death (HR: 0.38, 95% CI: 0.17 to 0.87; p = 0.02). The risk of death/myocardial infarction was similar with PEB versus BA (HR: 0.96, 95% CI: 0.46 to 2.0; p = 0.91). CONCLUSIONS At 3 years, the use of PEB as compared with PES to treat patients with limus-eluting stent restenosis has similar efficacy and safety. PEB remains superior to BA. The sustained efficacy without trade-off in safety supports the role of PEB as treatment option for patients with drug-eluting stent restenosis. (Intracoronary Stenting and Angiographic Results: Drug Eluting Stent In-Stent Restenosis: 3 Treatment Approaches [ISAR-DESIRE 3]; NCT00987324) (C) 2015 by the American College of Cardiology Foundation.
引用
收藏
页码:877 / 884
页数:8
相关论文
共 50 条
  • [21] Clinical Outcomes of Drug-Eluting versus Bare-Metal In-Stent Restenosis after the Treatment of Drug-Eluting Stent or Drug-Eluting Balloon: A Systematic Review and Meta-Analysis
    Yang, Yi-Xing
    Liu, Yin
    Li, Chang-Ping
    Lu, Peng-Ju
    Wang, Jiao
    Gao, Jing
    [J]. JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2020, 2020
  • [22] Safety and Efficacy of Drug-Eluting Balloons in the Treatment of Drug-Eluting In-Stent Restenosis: Experience of a Tertiary Care Hospital
    Dhakam, Sajid
    Jafferani, Asif
    Ahmed, Hafeez
    Rahman, Nasir
    Gowani, Ambreen
    [J]. JOURNAL OF INVASIVE CARDIOLOGY, 2012, 24 (07) : 335 - 338
  • [23] A Randomized Comparison of Drug-Eluting Balloon Versus Everolimus-Eluting Stent in Patients With Bare-Metal Stent-In-Stent Restenosis
    Alfonso, Fernando
    Jose Perez-Vizcayno, Maria
    Cardenas, Alberto
    Garcia del Blanco, Bruno
    Seidelberger, Bernhard
    Iniguez, Andres
    Gomez-Recio, Manuel
    Masotti, Monica
    Teresa Velazquez, M.
    Sanchis, Juan
    Garcia-Touchard, Arturo
    Zueco, Javier
    Bethencourt, Armando
    Melgares, Rafael
    Cequier, Angel
    Dominguez, Antonio
    Mainar, Vicente
    Lopez-Minguez, Jose R.
    Moreu, Jose
    Marti, Vicens
    Moreno, Raul
    Jimenez-Quevedo, Pilar
    Gonzalo, Nieves
    Fernandez, Cristina
    Macaya, Carlos
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (14) : 1378 - 1386
  • [24] Drug-eluting stents for the treatment of ostial coronary lesions: comparison of sirolimus-eluting stent with paclitaxel-eluting stent
    Chen, Jue
    Li, Jian-Jun
    Chen, Ji-Lin
    Qiao, Shu-Bing
    Xu, Bo
    Yang, Yue-Jin
    Gao, Run-Lin
    Qin, Xue-Wen
    Yuan, Jin-Qing
    Yao, Min
    Wu, Yong-Jian
    Liu, Hai-Bo
    Dai, Jun
    You, Shi-Jie
    [J]. CORONARY ARTERY DISEASE, 2008, 19 (07) : 507 - 511
  • [25] Aneurysm formation after drug-eluting balloon treatment of drug-eluting in-stent restenosis: First case report
    Vassilev, Dobrin
    Hazan, Maxim
    Dean, Larry
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2012, 80 (07) : 1223 - 1226
  • [26] Drug-eluting stent restenosis treatment: an "old" stent, a "new" balloon or a "newer" scaffold?
    Buccheri, Dario
    Cimino, Giuliana
    [J]. JOURNAL OF THORACIC DISEASE, 2016, 8 (12) : 3478 - 3483
  • [27] Elutax paclitaxel-eluting balloon followed by bare-metal stent compared with Xience V drug-eluting stent in the treatment of de novo coronary stenosis: A randomized trial
    Liistro, Francesco
    Porto, Italo
    Angioli, Paolo
    Grotti, Simone
    Ducci, Kenneth
    Falsini, Giovanni
    Bolognese, Leonardo
    [J]. AMERICAN HEART JOURNAL, 2013, 166 (05) : 920 - 926
  • [28] Comparison Among Drug-Eluting Balloon, Drug-Eluting Stent, and Plain Balloon Angioplasty for the Treatment of In-Stent Restenosis A Network Meta-Analysis of 11 Randomized, Controlled Trials
    Lee, Joo Myung
    Park, Jonghanne
    Kang, Jeehoon
    Jeon, Ki-Hyun
    Jung, Ji-hyun
    Lee, Sang Eun
    Han, Jung-Kyu
    Kim, Hack-Lyoung
    Yang, Han-Mo
    Park, Kyung Woo
    Kang, Hyun-Jae
    Koo, Bon-Kwon
    Kim, Hyo-Soo
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2015, 8 (03) : 382 - 394
  • [29] Treatment of Coronary Drug-Eluting Stent Restenosis by a Sirolimus- or Paclitaxel-Coated Balloon
    Ali, Rosli Mohd
    Kader, Muhamad Ali S. K. Abdul
    Ahmad, Wan Azman Wan
    Ong, Tiong Kiam
    Liew, Houng Bang
    Omar, Al-Fazir
    Zuhdi, Ahmad Syadi Mahmood
    Nuruddin, Amin Ariff
    Schnorr, Beatrix
    Scheller, Bruno
    [J]. JACC-CARDIOVASCULAR INTERVENTIONS, 2019, 12 (06) : 558 - 566
  • [30] Efficacy and safety of drug-eluting stent implantation for the treatment of in-stent restenosis occurring within bare-metal stent and drug-eluting stent
    Ge, Heng
    Zhang, Qing
    Zhou, Wei
    He, Qing
    Han, Zhi-hua
    He, Ben
    [J]. JOURNAL OF ZHEJIANG UNIVERSITY-SCIENCE B, 2010, 11 (08): : 553 - 560