Imaging and dosimetric errors in 4D PET/CT-guided radiotherapy from patient-specific respiratory patterns: a dynamic motion phantom end-to-end study

被引:8
|
作者
Bowen, S. R. [1 ,2 ]
Nyflot, M. J. [1 ]
Herrmann, C. [3 ]
Groh, C. M. [4 ]
Meyer, J. [1 ]
Wollenweber, S. D. [5 ]
Stearns, C. W. [5 ]
Kinahan, P. E. [2 ]
Sandison, G. A. [1 ]
机构
[1] Univ Washington, Sch Med, Dept Radiat Oncol, Seattle, WA 98105 USA
[2] Univ Washington, Sch Med, Dept Radiol, Seattle, WA 98195 USA
[3] Univ Wurzburg, Dept Comp Sci, D-97070 Wurzburg, Germany
[4] Univ Hosp Wurzburg, Dept Radiat Oncol, Wurzburg, Germany
[5] GE Healthcare Syst, Waukesha, WI USA
关键词
PET/CT; respiratory motion; IGRT; VMAT; dose painting; robotic couch tracking; POSITRON-EMISSION-TOMOGRAPHY; MODULATED RADIATION-THERAPY; CELL LUNG-CANCER; TRACKING SYSTEM; FDG-PET; RESPONSE-ASSESSMENT; COUCH TRACKING; TUMOR VOLUME; IMPACT; CT;
D O I
10.1088/0031-9155/60/9/3731
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Effective positron emission tomography / computed tomography (PET/CT) guidance in radiotherapy of lung cancer requires estimation and mitigation of errors due to respiratory motion. An end-to-end workflow was developed to measure patient-specific motion-induced uncertainties in imaging, treatment planning, and radiation delivery with respiratory motion phantoms and dosimeters. A custom torso phantom with inserts mimicking normal lung tissue and lung lesion was filled with [F-18] FDG. The lung lesion insert was driven by six different patient-specific respiratory patterns or kept stationary. PET/CT images were acquired under motionless ground truth, tidal breathing motion-averaged (3D), and respiratory phase-correlated (4D) conditions. Target volumes were estimated by standardized uptake value (SUV) thresholds that accurately defined the ground-truth lesion volume. Non-uniform dose-painting plans using volumetrically modulated arc therapy were optimized for fixed normal lung and spinal cord objectives and variable PET-based target objectives. Resulting plans were delivered to a cylindrical diode array at rest, in motion on a platform driven by the same respiratory patterns (3D), or motion-compensated by a robotic couch with an infrared camera tracking system (4D). Errors were estimated relative to the static ground truth condition for mean target-to-background (T/B-mean) ratios, target volumes, planned equivalent uniform target doses, and 2%-2 mm gamma delivery passing rates. Relative to motionless ground truth conditions, PET/CT imaging errors were on the order of 10-20%, treatment planning errors were 5-10%, and treatment delivery errors were 5-30% without motion compensation. Errors from residual motion following compensation methods were reduced to 5-10% in PET/CT imaging, <5% in treatment planning, and <2% in treatment delivery. We have demonstrated that estimation of respiratory motion uncertainty and its propagation from PET/CT imaging to RT planning, and RT delivery under a dose painting paradigm is feasible within an integrated respiratory motion phantom workflow. For a limited set of cases, the magnitude of errors was comparable during PET/CT imaging and treatment delivery without motion compensation. Errors were moderately mitigated during PET/CT imaging and significantly mitigated during RT delivery with motion compensation. This dynamic motion phantom end-to-end workflow provides a method for quality assurance of 4D PET/CT-guided radiotherapy, including evaluation of respiratory motion compensation methods during imaging and treatment delivery.
引用
收藏
页码:3731 / 3746
页数:16
相关论文
共 4 条
  • [1] Development of the 4D Phantom for patient-specific, end-to-end radiation therapy QA
    Malinowski, K.
    Noel, C.
    Lu, W.
    Lechleiter, K.
    Hubenschmidt, J.
    Low, D.
    Parikh, P.
    MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2007, 6510
  • [2] Dosimetric characteristics of a 2D silicon diode array for stereotactic radiotherapy end-to-end patient-specific QA
    Bai, Long
    Xiao, Qing
    Wang, Qiang
    Zhao, Jianling
    Li, Guangjun
    Bai, Sen
    RADIATION PHYSICS AND CHEMISTRY, 2020, 173
  • [3] Respiratory-Induced Errors in Tumor Quantification and Delineation in CT Attenuation-Corrected PET Images: Effects of Tumor Size, Tumor Location, and Respiratory Trace: A Simulation Study Using the 4D XCAT Phantom
    Parham Geramifar
    Mojtaba Shamsaie Zafarghandi
    Pardis Ghafarian
    Arman Rahmim
    Mohammad Reza Ay
    Molecular Imaging and Biology, 2013, 15 : 655 - 665
  • [4] Respiratory-Induced Errors in Tumor Quantification and Delineation in CT Attenuation-Corrected PET Images: Effects of Tumor Size, Tumor Location, and Respiratory Trace: A Simulation Study Using the 4D XCAT Phantom
    Geramifar, Parham
    Zafarghandi, Mojtaba Shamsaie
    Ghafarian, Pardis
    Rahmim, Arman
    Ay, Mohammad Reza
    MOLECULAR IMAGING AND BIOLOGY, 2013, 15 (06) : 655 - 665