Stepping-table gadolinium-enhanced digital subtraction MR angiography of the aorta and lower extremity arteries: Preliminary experience

被引:263
作者
Meaney, JFM
Ridgway, JP
Chakraverty, S
Robertson, I
Kessel, D
Radjenovic, A
Kouwenhoven, M
Kassner, A
Smith, MA
机构
[1] Leeds Gen Infirm, Dept Magnet Resonance, Leeds LS2 1EX, W Yorkshire, England
[2] Leeds Gen Infirm, Dept Phys Med, Leeds LS2 1EX, W Yorkshire, England
[3] Bradford Royal Infirm, Dept Radiol, Leeds, W Yorkshire, England
[4] St James Univ Hosp, Dept Radiol, Leeds LS9 7TF, W Yorkshire, England
[5] Philips Med Syst, Best, Netherlands
关键词
D O I
10.1148/radiology.211.1.r99ap1859
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To compare stepping-table digital subtraction gadolinium-enhanced magnetic resonance (MR) angiography of the distal aorta and lower extremity arteries with conventional catheter digital subtraction x-ray angiography in patients with arterio-occlusive disease. MATERIALS AND METHODS: Twenty patients underwent both conventional catheter angiography and fast three-dimensional gadolinium-enhanced MR angiography of the aorta and outflow vessels at 1.5 T; the images were acquired in three consecutive imaging locations during a single infusion of a gadolinium chelate. RESULTS: Compared with catheter angiography, according to the findings of two blinded independent reviewers, MR angiography had sensitivities of 81% and 89% and specificities of 91% and 95%, respectively, for demonstration of insignificant (less than or equal to 50%) stenosis versus significant (51%-100%) stenosis. For demonstration of occlusion, the sensitivity and specificity were 94% and 97%, respectively, by consensus. There was good interobserver correlation between the two readers overall (kappa = 0.65 for reporting the degree of narrowing in all lesions; 0.86, for reporting of insignificant versus significant stenoses; and 0.928, for reporting of occluded versus patent segments). CONCLUSION: Stepping-table digital subtraction contrast material-enhanced MR angiography has high accuracy compared with catheter angiography in patients with arterio-occlusive disease of the aorta and outflow vessels, these preliminary, study results suggest that this technique may ultimately provide a safe, noninvasive, and cost-effective alternative to catheter angiography.
引用
收藏
页码:59 / 67
页数:9
相关论文
共 32 条
[1]   MR-ANGIOGRAPHY VERSUS CONVENTIONAL X-RAY ANGIOGRAPHY IN THE LOWER-EXTREMITIES - EVERYONE WINS [J].
BORRELLO, JA .
RADIOLOGY, 1993, 187 (03) :615-617
[2]  
Bron KM, 1983, ABRAMS ANGIOGRAPHY V, P1835
[3]   PERIPHERAL VASCULAR-SURGERY WITH MAGNETIC-RESONANCE ANGIOGRAPHY AS THE SOLE PREOPERATIVE IMAGING MODALITY [J].
CARPENTER, JP ;
BAUM, RA ;
HOLLAND, GA ;
BARKER, CF ;
WILKERSON, D ;
ODONNELL, TF ;
BERKOWITZ, HD ;
RICOTTA, JR .
JOURNAL OF VASCULAR SURGERY, 1994, 20 (06) :861-871
[4]   FAST MR-ANGIOGRAPHY OF THE AORTOILIAC ARTERIES AND ARTERIES OF THE LOWER-EXTREMITY - VALUE OF BOLUS-ENHANCED, WHOLE-VOLUME SUBTRACTION TECHNIQUE [J].
DOUEK, PC ;
REVEL, D ;
CHAZEL, S ;
FALISE, B ;
VILLARD, J ;
AMIEL, M .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (02) :431-437
[5]   REDUCTION OF PARTIAL-VOLUME ARTIFACTS WITH ZERO-FILLED INTERPOLATION IN 3-DIMENSIONAL MR-ANGIOGRAPHY [J].
DU, YPP ;
PARKER, DL ;
DAVIS, WL ;
CAO, G .
JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (05) :733-741
[6]   Cardiac-gated MR angiography of the entire lower extremity: A prospective comparison with conventional angiography [J].
Glickerman, DJ ;
Obregon, RG ;
Schmiedl, UP ;
Harrison, SD ;
Macaulay, SE ;
Simon, HE ;
Kohler, TR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (02) :445-451
[7]   MR angiography of the iliac and upper femoral arteries using four different inflow techniques [J].
Ho, KY ;
deHaan, MW ;
Oei, TK ;
Koster, D ;
Kessels, AGH ;
Janevski, BK ;
Kitslaar, P ;
vanEngelshoven, JMA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 169 (01) :45-53
[8]   REAL-TIME INTERACTIVE MAGNETIC-RESONANCE-IMAGING [J].
HOLSINGER, AE ;
WRIGHT, RC ;
RIEDERER, SJ ;
FARZANEH, F ;
GRIMM, RC ;
MAIER, JK .
MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (03) :547-553
[9]   LOWER-EXTREMITIES - MR-ANGIOGRAPHY WITH A UNILATERAL TELESCOPIC PHASED-ARRAY COIL [J].
KOJIMA, KY ;
SZUMOWSKI, J ;
SHELEY, RC ;
QUINN, SF .
RADIOLOGY, 1995, 196 (03) :871-875
[10]   DIAGNOSTIC PERFORMANCE OF DIGITAL SUBTRACTION ANGIOGRAPHY (DSA) AND MAGNETIC-RESONANCE ANGIOGRAPHY (MRA) - PRELIMINARY-RESULTS IN VASCULAR OCCLUSIVE DISEASE OF THE ABDOMINAL AND LOWER-EXTREMITY ARTERIES [J].
KRUG, B ;
KUGEL, H ;
HARNISCHMACHER, U ;
HEINDEL, W ;
FISCHBACH, R ;
ALTENBURG, A ;
KRINGS, F .
EUROPEAN JOURNAL OF RADIOLOGY, 1995, 19 (02) :77-85