CT imaging of congenital lung lesions: effect of iterative reconstruction on diagnostic performance and radiation dose

被引:30
作者
Haggerty, Jay E. [1 ]
Smith, Ethan A. [1 ]
Kunisaki, Shaun M. [2 ]
Dillman, Jonathan R. [1 ]
机构
[1] Univ Michigan Hlth Syst, CS Mott Childrens Hosp, Dept Radiol, Sect Pediat Radiol, Ann Arbor, MI 48109 USA
[2] Univ Michigan Hlth Syst, CS Mott Childrens Hosp, Dept Surg, Pediat Surg Sect, Ann Arbor, MI 48109 USA
关键词
Computed tomography; Congenital pulmonary airway malformation; Infant; Iterative reconstruction; Lung; Radiation dose; Sequestration; COMPUTED-TOMOGRAPHY; CHEST; CHILDREN; QUALITY;
D O I
10.1007/s00247-015-3281-4
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Different iterative reconstruction techniques are available for use in pediatric computed tomography (CT), but these techniques have not been systematically evaluated in infants. To determine the effect of iterative reconstruction on diagnostic performance, image quality and radiation dose in infants undergoing CT evaluation for congenital lung lesions. A retrospective review of contrast-enhanced chest CT in infants (< 1 year) with congenital lung lesions was performed. CT examinations were reviewed to document the type of lung lesion, vascular anatomy, image noise measurements and image reconstruction method. CTDIvol was used to calculate size-specific dose estimates (SSDE). CT findings were correlated with intraoperative and histopathological findings. Analysis of variance and the Student's t-test were used to compare image noise measurements and radiation dose estimates between groups. Fifteen CT examinations used filtered back projection (FBP; mean age: 84 days), 15 used adaptive statistical iterative reconstruction (ASiR; mean age: 93 days), and 11 used model-based iterative reconstruction (MBIR; mean age: 98 days). Compared to operative findings, 13/15 (87%), 14/15 (93%) and 11/11 (100%) lesions were correctly characterized using FBP, ASiR and MBIR, respectively. Arterial anatomy was correctly identified in 12/15 (80%) using FBP, 13/15 (87%) using ASiR and 11/11 (100%) using MBIR. Image noise was less for MBIR vs. ASiR (P < 0.0001). Mean SSDE was different among groups (P = 0.003; FBP = 7.35 mGy, ASiR = 1.89 mGy, MBIR = 1.49 mGy). Congenital lung lesions can be adequately characterized in infants using iterative CT reconstruction techniques while maintaining image quality and lowering radiation dose.
引用
收藏
页码:989 / 997
页数:9
相关论文
共 18 条
[1]  
[Anonymous], BMC MED IMAGING
[2]  
Boone JMSK, 2011, REPORT AM ASS PHYS M
[3]   Current concepts - Computed tomography - An increasing source of radiation exposure [J].
Brenner, David J. ;
Hall, Eric J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (22) :2277-2284
[4]   Multisection CT Protocols: Sex- and Age-specific Conversion Factors Used to Determine Effective Dose from Dose-Length Product [J].
Deak, Paul D. ;
Smal, Yulia ;
Kalender, Willi A. .
RADIOLOGY, 2010, 257 (01) :158-166
[5]   Current Imaging of Prenatally Diagnosed Congenital Lung Lesions [J].
Epelman, Monica ;
Kreiger, Portia A. ;
Servaes, Sabah ;
Victoria, Teresa ;
Hellinger, Jeffrey C. .
SEMINARS IN ULTRASOUND CT AND MRI, 2010, 31 (02) :141-157
[6]   MDCT of Chest, Abdomen, and Pelvis Using Attenuation-Based Automated Tube Voltage Selection in Combination With Iterative Reconstruction: An Intrapatient Study of Radiation Dose and Image Quality [J].
Gonzalez-Guindalini, Fernanda Dias ;
Botelho, Marcos Paulo Ferreira ;
Toere, Hueseyin Guerkan ;
Ahn, Richard W. ;
Gordon, Leo I. ;
Yaghmai, Vahid .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 201 (05) :1075-1082
[7]   Trends in CT scan rates in children and pregnant women: teaching, private, public and nonprofit facilities [J].
Hoshiko, Sumi ;
Smith, Daniel ;
Fan, Cathyn ;
Jones, Carrie R. ;
McNeel, Sandra V. ;
Cohen, Ronald A. .
PEDIATRIC RADIOLOGY, 2014, 44 (05) :522-528
[8]   Model-Based Iterative Reconstruction Technique for Ultralow-Dose Chest CT Comparison of Pulmonary Nodule Detectability With the Adaptive Statistical Iterative Reconstruction Technique [J].
Katsura, Masaki ;
Matsuda, Izuru ;
Akahane, Masaaki ;
Yasaka, Koichiro ;
Hanaoka, Shohei ;
Akai, Hiroyuki ;
Sato, Jiro ;
Kunimatsu, Akira ;
Ohtomo, Kuni .
INVESTIGATIVE RADIOLOGY, 2013, 48 (04) :206-212
[9]   Emerging Techniques for Dose Optimization in Abdominal CT [J].
Kaza, Ravi K. ;
Platt, Joel F. ;
Goodsitt, Mitchell M. ;
Al-Hawary, Mahmoud M. ;
Maturen, Katherine E. ;
Wasnik, Ashish P. ;
Pandya, Amit .
RADIOGRAPHICS, 2014, 34 (01) :4-U51
[10]   Computed tomography depiction of small pediatric vessels with model-based iterative reconstruction [J].
Koc, Gonca ;
Courtier, Jesse L. ;
Phelps, Andrew ;
Marcovici, Peter A. ;
MacKenzie, John D. .
PEDIATRIC RADIOLOGY, 2014, 44 (07) :787-794