System-wide Inertial Response from Fixed Speed and Variable Speed Wind Turbines

被引:0
作者
Ruttledge, Lisa [1 ]
Flynn, Damian [1 ]
机构
[1] Univ Coll Dublin, Sch Elect Elect & Mech Engn, Elect Res Ctr, Dublin 2, Ireland
来源
2011 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING | 2011年
基金
爱尔兰科学基金会;
关键词
Active power; DFIG wind turbines; frequency control; inertia; grid code; wind power plants;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
As wind penetration levels on power systems increase worldwide, the dynamic characteristics of these systems are changing due to the displacement of synchronous generation. One issue, of particular concern, is the resulting reduction in system inertia. Modern, variable speed wind turbines are controlled by power electronics and so do not inherently contribute to the inertial response of the system. Such devices can however be fitted with a control loop which provides an active power response to significant frequency deviations, similar to the inertial response of fixed speed wind turbines and synchronous generation. However, the response of variable speed turbines is dependent on local wind speeds and so cannot be quantified deterministically by system operators. This paper examines the potential for wind generation to contribute to system inertial response and considers the aggregated inertial response capabilities of fixed speed and variable speed wind generation.
引用
收藏
页数:7
相关论文
共 17 条
[1]  
[Anonymous], 9 INT WORKSH LARG SC
[2]   Participation of doubly fed induction wind generators in system frequency regulation [J].
de Almeida, Rogerio G. ;
Pecas Lopes, J. A. .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2007, 22 (03) :944-950
[3]  
Dernbach M, 2010, 9 INT WORKSH LARG SC
[4]   A new approach to quantify reserve demand in systems with significant installed wind capacity [J].
Doherty, R ;
O'Malley, M .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2005, 20 (02) :587-595
[5]   An Assessment of the Impact of Wind Generation on System Frequency Control [J].
Doherty, Ronan ;
Mullane, Alan ;
Nolan, Gillian ;
Burke, Daniel J. ;
Bryson, Alexander ;
O'Malley, Mark .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2010, 25 (01) :452-460
[6]  
EirGrid and SONI, 2010, EIRGRID SONI
[7]   Comparison of the response of doubly fed and fixed-speed induction generator wind turbines to changes in network frequency [J].
Ekanayake, J ;
Jenkins, N .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2004, 19 (04) :800-802
[8]   Control of DFIG wind turbines [J].
Ekanayake, J ;
Holdsworth, L ;
Jenkins, N .
POWER ENGINEER, 2003, 17 (01) :28-32
[9]  
Grillo S., 2010, 45 INT UPEC CARD
[10]   Power system frequency response from fixed speed and doubly fed induction generator based wind turbines [J].
Holdsworth, L ;
Ekanayake, JB ;
Jenkins, N .
WIND ENERGY, 2004, 7 (01) :21-35