Seventy kilovolt ultra-low dose CT of the paranasal sinus: first clinical results

被引:23
作者
Bodelle, B. [1 ]
Wichmann, J. L. [1 ]
Klotz, N. [1 ]
Lehnert, T. [1 ]
Vogl, T. J. [1 ]
Luboldt, W. [1 ]
Schulz, B. [1 ]
机构
[1] Goethe Univ Frankfurt, Dept Diagnost & Intervent Radiol, D-60590 Frankfurt, Germany
关键词
X-RAY EXAMINATIONS; COMPUTED-TOMOGRAPHY; IMAGE QUALITY; ITERATIVE RECONSTRUCTION; RADIATION-EXPOSURE; MULTIDETECTOR CT; SPIRAL CT; REDUCTION; RELIABILITY; DIAGNOSIS;
D O I
10.1016/j.crad.2015.03.002
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: To evaluate the diagnostic image quality and radiation dose of low-dose 70 kV computed tomography (CT) of the paranasal sinus in comparison to 100 and 120 kV CT. MATERIALS AND METHODS: CT of the paranasal sinus was performed in 127 patients divided into three groups using different tube voltages and currents (70 kV/75 mAs, ultra-low dose protocol, n = 44; 100 kV/40 mAs, standard low-dose protocol, n = 42; 120 kV/40 mAs, standard protocol, n = 41). CT dose index (CTDIvol), dose length product (DLP), attenuation, image noise and signal-to-noise ratio (SNR) were compared between the groups using Wilcoxon-Mann-Whitney U-test. Subjective diagnostic image quality was compared by using a five-point scale (1 = non-diagnostic, 5 = excellent, read by two readers in consensus) and Cohen's weighted kappa analysis for interobserver agreement. RESULTS: Radiation dose was significantly lower with 70 kV acquisition than 100 and 120 kV (DLP: 31 versus 52 versus 82 mGy.cm; CTDI 2.33 versus 3.95 versus 6.31 mGy, all p < 0.05). Mean SNR (70 kV: 0.37; 100 kV: 0.21; 120 kV: 0.13; p < 0.05) and organ attenuation increased significantly with lower voltages. All examinations showed diagnostic image quality. Subjective diagnostic image quality was higher with standard protocols than the 70 kV protocol (120 kV: 5.0; 100 kV: 4.5; 70 kV: 3.5, p <0.05) without significant differences with substantial interobserver agreement (kappa > 0.59). CONCLUSION: The ultra-low dose (70 kV) CT imaging of the paranasal sinus allowed for significant dose reduction by 61% and an increased attenuation of organ structures in comparison to standard acquisition while maintaining diagnostic image quality with a slight reduction in subjective image quality. (C) 2015 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:711 / 715
页数:5
相关论文
共 32 条
[1]   Conventional sinus radiography compared with CT in the diagnosis of acute sinusitis [J].
Aalokken, TM ;
Hagtvedt, T ;
Dalen, I ;
Kolbenstvedt, A .
DENTOMAXILLOFACIAL RADIOLOGY, 2003, 32 (01) :60-62
[2]   Low-dose computed tomography of the paranasal sinuses: radiation doses and reliability analysis [J].
Abul-Kasim, Kasim ;
Strombeck, Anita ;
Sahlstrand-Johnson, Pernilla .
AMERICAN JOURNAL OF OTOLARYNGOLOGY, 2011, 32 (01) :47-51
[3]   Reliability of High-Pitch Ultra-Low-Dose Paranasal Sinus Computed Tomography for Evaluating Paranasal Sinus Anatomy and Sinus Disease [J].
Aksoy, Elif Ayanoglu ;
Ozden, Sila Ulus ;
Karaarslan, Ercan ;
Unal, Omer Faruk ;
Tanyeri, Hasan .
JOURNAL OF CRANIOFACIAL SURGERY, 2014, 25 (05) :1801-1804
[4]  
[Anonymous], 1999, EUR16252
[5]   Multidetector CT of the paranasal sinus: Potential for radiation dose reduction [J].
Brem, Matthias H. ;
Zamani, Amir A. ;
Riva, Roberto ;
Zou, Kelly H. ;
Rumboldt, Zoran ;
Hennig, Friedrich F. ;
Kikinis, Ron ;
Norbash, Alexander M. ;
Schoepf, U. Joseph .
RADIOLOGY, 2007, 243 (03) :847-852
[6]   Current concepts - Computed tomography - An increasing source of radiation exposure [J].
Brenner, David J. ;
Hall, Eric J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (22) :2277-2284
[7]   Reducing the radiation dose for low-dose CT of the paranasal sinuses using iterative reconstruction: Feasibility and image quality [J].
Bulla, Stefan ;
Blanke, Philipp ;
Hassepass, Frederike ;
Krauss, Tobias ;
Winterer, Jan Thorsten ;
Breunig, Christine ;
Langer, Mathias ;
Pache, Gregor .
EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (09) :2246-2250
[8]   Pediatric CT Radiation Dose: How Low Can You Go? [J].
Cohen, Mervyn D. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (05) :1292-1303
[9]   Radiation dose to the lens in sequential and spiral CT of the facial bones and sinuses [J].
Czechowski, J ;
Janeczek, J ;
Kelly, G ;
Johansen, J .
EUROPEAN RADIOLOGY, 2001, 11 (04) :711-713
[10]  
Dammann F, 2007, RADIOLOGE, V47, P576, DOI 10.1007/s00117-007-1502-z