Line focal X-ray source imaging

被引:0
作者
Liu Xin [1 ]
Yi Ming-Hao [1 ]
Guo Jin-Chuan [1 ]
机构
[1] Shenzhen Univ, Coll Optoelect Engn, Key Lab Optoelect Devices & Syst, Minist Educ & Guangdong Prov, Shenzhen 518060, Peoples R China
基金
中国国家自然科学基金;
关键词
X-ray; X-ray imaging; image reconstruction; PHASE; CONTRAST;
D O I
10.7498/aps.65.219501
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
High spatial coherent and bright X-ray beam is necessary condition for acquiring high quality radiography image. However, traditional X-ray tube can only provide high flux X-ray light or high spatial coherent light. In general, X-ray photons are generated by using energetic electrons with several tens or even hundreds keV to hit a target. Unfortunately, over 99% electron energy are converted into heat rather than the energy of X-ray photons. Thus, the heat dissipation of the target restricts the emission power and radiation flux. Increasing the emission area of X-ray can relieve the heat dissipation, but it would bring another serious problem-low spatial coherence that is in inverse proportion to emission area or focal spot. In order to solve the conflict between brightness and spatial coherence, an X-ray source with one-dimensional coherence is proposed in this work. The new X-ray source has a special focal spot where one side is small enough to ensure the spatial coherence and the perpendicular side is big enough to provide sufficient X-ray flux. In the direction of long side, the long size of focal spot will result in losing the image details. Consequently, an algorithm of superposition and rotation, in which many images with different rotation angles are added together, is proposed to retrieve the lost information. On the other hand, the spatial transfer function of superposition is analyzed in the frequency domain, and the result shows that the method of superposition can transfer more components of frequency than single image. Based on a traditional X-ray tube, a line focal spot source is designed and fabricated. Two series of experiments are performed for different destinations. After 17 images of a chip with different rotation angles and the line focal spot are collected, those images are rotated in the reverse direction and added together. The image of superposition clearly presents some details which are invisible in one of 17 images. At the same tube voltage and for the same object, some comparative experiments with micro-focus source, line focal spot source and normal focal spot source are presented. Compared with traditional X-ray tube, line focal spot source can provide high-resolution image. In the aspect of image visibility, the new source has definite advantages compared with micro-focus source, despite no improvement in imaging resolution. Finally, the reason for the difference in imaging resolution is discussed from the aspects of spatial coherence and light flux.
引用
收藏
页数:7
相关论文
共 21 条
[1]   Two-Dimensional X-Ray Beam Phase Sensing [J].
Berujon, Sebastien ;
Ziegler, Eric ;
Cerbino, Roberto ;
Peverini, Luca .
PHYSICAL REVIEW LETTERS, 2012, 108 (15)
[2]  
Born M., 1999, PRINCIPLES OPTICS, P459
[3]   Diffraction enhanced x-ray imaging [J].
Chapman, D ;
Thomlinson, W ;
Johnston, RE ;
Washburn, D ;
Pisano, E ;
Gmur, N ;
Zhong, Z ;
Menk, R ;
Arfelli, F ;
Sayers, D .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (11) :2015-2025
[4]   Quantitative in-line phase-contrast imaging with multienergy x rays [J].
Gureyev, TE ;
Mayo, S ;
Wilkins, SW ;
Paganin, D ;
Stevenson, AW .
PHYSICAL REVIEW LETTERS, 2001, 86 (25) :5827-5830
[5]   On x-ray phase imaging with a point source [J].
Gureyev, TE ;
Wilkins, SW .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1998, 15 (03) :579-585
[6]   Some simple rules for contrast, signal-to-noise and resolution in in-line x-ray phase-contrast imaging [J].
Gureyev, Timur E. ;
Nesterets, Yakov I. ;
Stevenson, Andrew W. ;
Miller, Peter R. ;
Pogany, Andrew ;
Wilkins, Stephen W. .
OPTICS EXPRESS, 2008, 16 (05) :3223-3241
[7]   A half-covered helical cone-beam reconstruction algorithm based on the Radon inversion transformation [J].
Han Yu ;
Li Lei ;
Yan Bin ;
Xi Xiao-Qi ;
Hu Guo-En .
ACTA PHYSICA SINICA, 2015, 64 (05)
[8]   Noise analysis of hard X-ray differential phase contrast imaging [J].
Huang Jian-Heng ;
Du Yang ;
Lei Yao-Hu ;
Liu Xin ;
Guo Jin-Chuan ;
Niu Han-Ben .
ACTA PHYSICA SINICA, 2014, 63 (16)
[9]  
Liu X.F.X.F., 2007, THESIS
[10]   In-Line Phase-Contrast X-ray Imaging and Tomography for Materials Science [J].
Mayo, Sheridan C. ;
Stevenson, Andrew W. ;
Wilkins, Stephen W. .
MATERIALS, 2012, 5 (05) :937-965