Comparison between the standard and staggered layout for cooling fins in forced convection cooling

被引:14
作者
Leon, O
De Mey, G
Dick, E
Vierendeels, J
机构
[1] Ghent Univ, Dept Elect & Informat Syst, B-9000 Ghent, Belgium
[2] Ghent Univ, Dept Flow Heat & Combust, B-9000 Ghent, Belgium
关键词
D O I
10.1115/1.1602709
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The performance of an array of staggered and nonstaggered cooling fins is compared, looking not only into the traditional objective of maximum heat transfer flux, but also to obtain it with the minimum flow resistance. Three different models were studied to obtain the ratio between the heat removed and the energy spent for the coolant flow going through the cooling fins. The study is done numerically using the computational fluid dynamic software FLUENT. The results show the advantages of the staggered model compared to the standard model since for a given incoming velocity, the use of a staggered heat sink always leads to a maximization of the heat transfer flux. The significant positive difference in the thermal performance of the staggered model permits the reduction of the incoming velocity with the consequent reduction in the pressure drop, and power consumption. The authors consider this research as a quite interesting approach as compared to other research where the flow resistance has not been taken into account.
引用
收藏
页码:442 / 446
页数:5
相关论文
共 14 条
[1]  
Azar K., 2000, J ELECT COOLING, V6, P42
[2]  
BIBER CR, 1996, J ELECT COOLING, V2, P22
[3]  
*FLUENT INC, 1996, SOFTW MAN
[4]  
HOLMAN JP, 1998, HEAT TRANSFER, P150
[5]   CONVECTION HEAT-TRANSFER IN ELECTRONIC EQUIPMENT COOLING [J].
INCROPERA, FP .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1988, 110 (4B) :1097-1111
[6]  
INCROPERA FP, 1985, INTRO HEAT TRANSFER, P243
[7]  
KIN SJ, 1996, AIR COOLING TECHNOLO, P2
[8]   Study of the optimal layout of cooling fins in forced convection cooling [J].
Leon, O ;
De Mey, G ;
Dick, E .
MICROELECTRONICS RELIABILITY, 2002, 42 (07) :1101-1111
[9]  
MALING GC, 1996, J ELECT COOLING, V2, P14
[10]   THE OPTIMAL COOLING OF A STACK OF HEAT GENERATING BOARDS WITH FIXED PRESSURE-DROP, FLOW-RATE OR PUMPING POWER [J].
MEREU, S ;
SCIUBBA, E ;
BEJAN, A .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1993, 36 (15) :3677-3686