Fracture of the ABC® ceramic liner -: A report of three cases

被引:18
作者
Diwanji, Sanket R. [1 ]
Seon, Jong Kenn [1 ]
Song, Eun. Kyoo [1 ]
Yoon, Taek Rim [1 ]
机构
[1] Chonnam Natl Univ, Hwasun Hosp, Ctr Joint Dis, Jeonnam, South Korea
关键词
D O I
10.1097/BLO.0b013e3180dc8c35
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The fracture rate of third-generation ceramic liners is greatly reduced compared with first- and second-generation liners because of improvement in the design and manufacturing process. The ABC (R) (alumina-bearing couple) ceramic liner is one such design, and fracture of this type of liner has not been reported. We report three cases of fracture of an ABC (R) ceramic liner occurring within 3 years of implantation. The liner was broken into multiple pieces in two patients, whereas in one patient it was broken only in its periphery. These patients were treated with debridement and cementation of the, metal-inlay polyethylene liner into the retained acetabular shell.
引用
收藏
页码:242 / 246
页数:5
相关论文
共 19 条
[1]   Revision total hip arthroplasty performed after fracture of a ceramic femoral head - A multicenter survivorship study [J].
Allain, J ;
Roudot-Thoraval, F ;
Delecrin, J ;
Anract, P ;
Migaud, H ;
Goutallier, D .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (05) :825-830
[2]  
Capello William N, 2005, Instr Course Lect, V54, P171
[3]   Alumina ceramic bearings for total hip arthroplasty - Five-year results of a prospective randomized study [J].
D'Antonio, J ;
Capello, W ;
Manley, M ;
Naughton, M ;
Sutton, K .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (436) :164-171
[4]   New experience with alumina-on-alumina ceramic bearings for total hip arthroplasty [J].
D'Antonio, J ;
Capello, W ;
Manley, M ;
Bierbaum, B .
JOURNAL OF ARTHROPLASTY, 2002, 17 (04) :390-397
[5]   Ceramic liner fracture after cementless alumina-on-alumina total hip arthroplasty [J].
Ha, Yong-Chan ;
Kim, Shin-Yoon ;
Kim, Hee Joong ;
Yoo, Jeong Joon ;
Koo, Kyung-Hoi .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2007, (458) :106-110
[6]   Polyethylene liner cementation into fixed acetabular shells [J].
Haft, GF ;
Heiner, AD ;
Callaghan, JJ ;
Dorr, LD ;
Wan, ZN ;
Long, W ;
Longjohn, DB ;
Brown, TD .
JOURNAL OF ARTHROPLASTY, 2002, 17 (04) :167-170
[7]   Fractures of ceramic bearings - History and present status [J].
Hannouche, D ;
Nich, C ;
Bizot, P ;
Meunier, A ;
Nizard, RM ;
Sedel, L .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (417) :19-26
[8]   Alumina ceramic-on-ceramic total hip replacement with a layered acetabular component [J].
Hasegawa, M. ;
Sudo, A. ;
Uchida, A. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (07) :877-882
[9]   Delayed fracture of a ceramic insert with modern ceramic total hip replacement [J].
Min, Byung-Woo ;
Song, Kwang-Soon ;
Kang, Chul-Hyung ;
Bae, Ki-Cheol ;
Won, Ye-Yeon ;
Lee, Kwon-Yong .
JOURNAL OF ARTHROPLASTY, 2007, 22 (01) :136-139
[10]   Two- to 9-year clinical results of alumina ceramic-on-ceramic THA [J].
Murphy, Stephen B. ;
Ecker, Timo M. ;
Tannast, Moritz .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (453) :97-102