共 50 条
The first report of transcatheter aortic valve-in-valve implantation within the expandable Inspiris Resilia® bioprosthetic valve
被引:6
|作者:
Mehdiani, Arash
[1
]
Chekhoeva, Agunda
[1
]
Klein, Kathrin
[2
]
Lichtenberg, Artur
[1
]
机构:
[1] Heinrich Heine Univ Hosp, Dept Cardiac Surg, Moorenstr 5, D-40225 Dusseldorf, Germany
[2] Heinrich Heine Univ Hosp, Dept Cardiol Pneumol & Angiol, Dusseldorf, Germany
关键词:
Transcatheter aortic valve replacement;
Valve-in-valve TAVR;
Balloon aortic valvuloplasty;
Aortic stenosis;
Inspiris Resilia (R);
D O I:
10.1093/ejcts/ezac394
中图分类号:
R5 [内科学];
学科分类号:
1002 ;
100201 ;
摘要:
A 61-year-old male who underwent aortic valve replacement with an Inspiris Resilia (R) aortic bioprosthetic through an upper partial sternotomy due to severe aortic valve stenosis was presented 1 year later to our hospital suffering from dyspnoea and chest pain. The transthoracic echocardiography demonstrated moderate haemodynamic structural valve deterioration with a mean gradient of 29 mmHg and a valve area of 0.9 cm(2). Due to relatively high-risk of reoperation, valve-in-valve transcatheter aortic valve replacement with Sapien 3 (R) 29 mm, followed by balloon valvuloplasty, was successfully performed. To the best of our knowledge, this is the first published case of valve-in-valve transcatheter aortic valve replacement into a degenerated Inspiris Resilia (R) aortic valve.
引用
收藏
页数:3
相关论文