Developing a dose-volume histogram computation program for brachytherapy

被引:4
作者
Panitsa, E [1 ]
Rosenwald, JC
Kappas, C
机构
[1] Univ Patras, Dept Med Phys, Patras 26500, Greece
[2] Inst Curie, Serv Phys Med, F-75005 Paris, France
关键词
D O I
10.1088/0031-9155/43/8/009
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A dose-volume histogram (DVH) computation program was developed for brachytherapy treatment planning in an attempt to benefit from the DVH's ability to present graphically information on 3D dose distributions. The program is incorporated into a planning system that utilizes a pair of orthogonal radiographs to localize the radiation sources. DVHs are calculated for the volume of tissue enclosed by an isodose sur-face (e.g. half the value of the reference isodose). The calculation algorithm is I,based on a non-uniform random sampling that gives a denser point distribution at the centre of the implants. Our program was tested and proved to be fast enough for clinical use and sufficiently accurate (i.e. computation time of 20 s and less than 2% relative error for one point source, for 100000 calculation points). The accuracy improves when a larger calculation point number is used, but the computation time also increases proportionally. The DVH is presented in the form of a simple graph or table, or as Anderson's 'natural' DVH graph. The cumulative DVH tables can be used to extract a series of indexes characterizing the homogeneity and the dose levels of the distribution in the treatment volume and the surrounding tissues. If a reference plan is available, the DVH results can be assessed relative to the reference plan's DVH.
引用
收藏
页码:2109 / 2121
页数:13
相关论文
共 22 条
[1]   A NATURAL VOLUME-DOSE HISTOGRAM FOR BRACHYTHERAPY [J].
ANDERSON, LL .
MEDICAL PHYSICS, 1986, 13 (06) :898-903
[2]  
[Anonymous], 1985, 38 ICRU
[3]  
*CFMRI, 1983, 1 CFMRI
[4]   DOSE-VOLUME HISTOGRAMS [J].
DRZYMALA, RE ;
MOHAN, R ;
BREWSTER, L ;
CHU, J ;
GOITEIN, M ;
HARMS, W ;
URIE, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 21 (01) :71-78
[5]   SAMPLING TECHNIQUES FOR THE EVALUATION OF TREATMENT PLANS - COMMENT [J].
JACKSON, A ;
MOHAN, R ;
BALDWIN, B .
MEDICAL PHYSICS, 1993, 20 (05) :1375-1376
[6]   DOSE-VOLUME HISTOGRAM COMPUTATIONS FOR SMALL INTRACRANIAL VOLUMES [J].
KOOY, HM ;
NEDZI, LA ;
ALEXANDER, E ;
LOEFFLER, JS ;
LEDOUX, RJ .
MEDICAL PHYSICS, 1993, 20 (03) :755-760
[7]   THE APPLICATION OF DOSE VOLUME HISTOGRAMS TO THE PARIS AND MANCHESTER SYSTEMS OF BRACHYTHERAPY DOSIMETRY [J].
LANGMACK, KA ;
THOMAS, SJ .
BRITISH JOURNAL OF RADIOLOGY, 1995, 68 (805) :42-48
[8]   QUANTIFYING THE EFFECT OF DOSE INHOMOGENEITY IN BRACHYTHERAPY - APPLICATION TO PERMANENT PROSTATIC IMPLANT WITH I-125 SEEDS [J].
LING, CC ;
ROY, J ;
SAHOO, N ;
WALLNER, K ;
ANDERSON, L .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 28 (04) :971-978
[9]   THE EVALUATION OF OPTIMIZED IMPLANTS FOR IDEALIZED IMPLANT GEOMETRIES [J].
LOW, DA ;
WILLIAMSON, JF .
MEDICAL PHYSICS, 1995, 22 (09) :1477-1485
[10]   FURTHER DISCUSSIONS ON SAMPLING METHODS - A RESPONSE [J].
LU, XQ ;
CHIN, LM .
MEDICAL PHYSICS, 1993, 20 (05) :1381-1385