摘要
This work investigated the fundamental capabilities and limitations of three-dimensional (3D) combustion measurements based on computed tomography of chemiluminescence (CTC). Experimental, computational, and analytical studies were conducted to map out the fundamental relationship of several parameters important to 3D measurements, including the achievable spatial resolution, the dimension of the measurement volume, and the signal level. The spatial resolution was analyzed both from the Fourier Slice Theorem (FST) and from linear algebraic (LA) considerations, and two limits (the FST and LA limits) were obtained to predict the achievable spatial resolution in tomographic measurements. The achievable signal level and measurement volume were also analyzed under different conditions. These results suggest that it is advantageous to implement tomographic diagnostic such that the projection image fills the camera chip completely. Under such an implementation, the average signal level increases linearly with respect to the size of the measurement volume, and the spatial resolution under the LA limits degrades linearly with respect to the measurement volume if the chemiluminescence emission intensity remains constant. We expect these results to be valuable not only for CTC, but also for tomography diagnostics based another types of signals because the mathematical formulation in this work is not specific to chemiluminescence signals. (C) 2014 The Combustion Institute. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:642 / 651
页数:10
相关论文
共 50 条
  • [21] Application of industrial 3D computed tomography
    Maisl, M
    Reiter, H
    Purschke, M
    Zabler, E
    Rosenberger-Koch, M
    METALL, 2001, 55 (06): : 368 - 371
  • [22] Accuracy of 3D Reconstructions Based on Cone Beam Computed Tomography
    Maret, D.
    Molinier, F.
    Braga, J.
    Peters, O. A.
    Telmon, N.
    Treil, J.
    Inglese, J. M.
    Cossie, A.
    Kahn, J. L.
    Sixou, M.
    JOURNAL OF DENTAL RESEARCH, 2010, 89 (12) : 1465 - 1469
  • [23] ANGULAR UPSAMPLING OF PROJECTION MEASUREMENTS IN 3D COMPUTED TOMOGRAPHY USING A SPARSITY PRIOR
    Karimi, Davood
    Ward, Rabab
    Ford, Nancy
    2015 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING (ICIP), 2015, : 3363 - 3367
  • [24] Precision of craniofacial measurements using 3D computed tomography for human identificacion.
    Rocha, SS
    Ramos, DLP
    Cavalcanti, MGP
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : 128 - 128
  • [25] Capabilities of industrial computed tomography in the field of dimensional measurements
    Horvatic Novak, A.
    Runje, B.
    Stepanic, J.
    ADVANCES IN PRODUCTION ENGINEERING & MANAGEMENT, 2017, 12 (03): : 245 - 253
  • [26] Computed tomography based 3D modeling and analysis of human knee joint
    Soni, Abhishek
    Modi, Yashwant Kumar
    Agrawal, Sanat
    MATERIALS TODAY-PROCEEDINGS, 2018, 5 (11) : 24194 - 24201
  • [27] 3D Morphology of Internal Defects in Wooden Products Based on Computed Tomography
    Zhao, Guiling
    Liu, Chang
    Qiu, Zhaowen
    Deng, Zongji
    Gong, Jinhua
    BIORESOURCES, 2021, 16 (03) : 6267 - 6280
  • [28] Direct 3D Quantitative Measurements and Optimal View Determination for TAVR Procedure by Computed Tomography
    Valle, Javier
    Chen, James
    Hansgen, Adam
    Wiktor, Dominik
    Cleveland, Joseph
    Moloo, Jamaluddin
    Messenger, John
    Carroll, John
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2017, 70 (18) : B269 - B270
  • [29] Accuracy and reliability of measurements obtained from computed tomography 3D volume rendered images
    Stull, Kyra E.
    Tise, Meredith L.
    Ali, Zabiullah
    Fowler, David R.
    FORENSIC SCIENCE INTERNATIONAL, 2014, 238 : 133 - 140
  • [30] Thebesian valve in 3D cardiac computed tomography
    Mlynarska, A.
    Mlynarski, R.
    Golba, K. S.
    Sosnowski, M.
    EUROPEAN HEART JOURNAL, 2017, 38 : 1171 - 1171