Biofiltration of air contaminated with toluene

被引:24
作者
Elmrini, H [1 ]
Kerdouss, F [1 ]
Jorio, H [1 ]
Heitz, M [1 ]
机构
[1] Univ Sherbrooke, Fac Engn, Dept Chem Engn, Sherbrooke, PQ J1K 2R1, Canada
关键词
toluene; biofiltration; shut-down; reacclimation; theoretical model validation;
D O I
10.1080/09593332208618230
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In industrial activities, operation of air biofilters may be interrupted for a long period of time. In order to examine the effect of shut-down on the performance of biofilters, a pilot scale biofiltration unit was restarted up after a non-use duration of eight months. After a reacclimation period of eight days, the biofilter reached an elimination capacity of 35 g.m(-3).h(-1) compared to 38 g.m(-3).h(-1) before shut-down, for the same operating conditions. The results obtained indicate that the microorganism activity was completely restored and this was confirmed by the microbial count tests performed on filter bed material samples. The impact of varying the inlet concentration of toluene on biofilter performance was also investigated. A maximum elimination capacity of 120 g.m(-3).h(-1) was achieved, compared to 135 g.m(-3).h(-1) before shut-down. The biofilter removal efficiency exceeded 96% for inlet concentrations up to 1.8 g.m(-3);. Temperature measurements revealed that the filter bed temperature depends strongly on the intensity of microbial activity and the biofilter effectiveness in eliminating toluene. Experimental data were compared with the calculations of a mathematical model. Comparison showed that the theoretical model was successful in predicting the performance of the biofiltration unit.
引用
收藏
页码:927 / 940
页数:14
相关论文
共 21 条
  • [1] Biofiltration of BTEX contaminated air streams using compost-activated carbon filter media
    Abumaizar, RJ
    Kocher, W
    Smith, EH
    [J]. JOURNAL OF HAZARDOUS MATERIALS, 1998, 60 (02) : 111 - 126
  • [2] BENITEZ J, 1995, P 88 ANN M AIR WAST
  • [3] Treatment of toluene in an air stream by a biotrickling filter packed with slags
    Chou, MS
    Wu, FL
    [J]. JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1999, 49 (04): : 386 - 398
  • [4] *ENV CAN, 1999, EN4049511997F ENV CA
  • [5] Jorio H, 1998, J CHEM TECHNOL BIOT, V73, P183, DOI 10.1002/(SICI)1097-4660(1998110)73:3<183::AID-JCTB943>3.0.CO
  • [6] 2-7
  • [7] Biofiltration of air
    Jorio, H
    Heitz, M
    [J]. CANADIAN JOURNAL OF CIVIL ENGINEERING, 1999, 26 (04) : 402 - 424
  • [8] Biological elimination of VOCs in biofilter
    Kiared, K
    Bibeau, L
    Brzezinski, R
    Viel, G
    Heitz, M
    [J]. ENVIRONMENTAL PROGRESS, 1996, 15 (03): : 148 - 152
  • [9] Kraakman N. J. R., 1997, Mededelingen Faculteit Landbouwkundige en Toegepaste Biologische Wetenschappen Universiteit Gent, V62, P1535
  • [10] Effect of periods of non-use on biofilter performance
    Martin, FJ
    Loehr, RC
    [J]. JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1996, 46 (06): : 539 - 546