Experimental analysis of a direct expansion solar assisted heat pump with integral storage tank for domestic water heating under zero solar radiation conditions

被引:63
作者
Fernandez-Seara, Jose [1 ]
Pineiro, Carolina [1 ]
Alberto Dopazo, J. [1 ]
Fernandes, F. [2 ]
Sousa, Paulo X. B. [2 ]
机构
[1] Univ Vigo, ETS Ingn Ind, Area Maquinas & Motores Term, Vigo 36310, Spain
[2] Energie Est Lda, Dept Invest & Desenvolvimento, Zona Ind Laundos, P-570311 Laundos, Povoa De Varzim, Portugal
关键词
Solar assisted heat pump; Direct expansion; Solar collector; Heat pump transient analysis; THERMAL PERFORMANCE;
D O I
10.1016/j.enconman.2012.01.018
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper deals with the experimental evaluation of the performance of a direct expansion solar assisted heat pump water heating (DX-SAHPWH) system working under zero solar radiation conditions at static heating operation mode of the storage tank. The DX-SAHPWH system includes two bare solar collectors as evaporator, a R134a rotary-type hermetic compressor, a thermostatic expansion valve and a helical coil condenser immersed in a 300 L water storage tank. The zero solar radiation and stable ambient air temperature working conditions were established by placing the solar collectors into a climate chamber. The analysis is based on experimental data taken from the DX-SAHPWH provided by the manufacturer and equipped with an appropriate data acquisition system. In the paper, the experimental facility, the data acquisition system and the experimental methodology are described. Performance parameters to evaluate the energy efficiency, such as COP and equivalent seasonal performance factors (SPFe) for the heating period, and the water thermal stratification in the storage tank are defined and obtained from the experimental data. Results from the experimental analysis under transient operating working conditions of the DX-SAHPWH system and its main components are shown and discussed. Lastly, the Huang and Lee DX-SAHPWH performance evaluation method was applied resulting in a characteristic COP of 3.23 for the DX-SAHPWH system evaluated under zero solar radiation condition. (c) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1 / 8
页数:8
相关论文
共 19 条
  • [1] Effect of load pattern on solar-boosted heat pump water heater performance
    Anderson, T. N.
    Morrison, G. L.
    [J]. SOLAR ENERGY, 2007, 81 (11) : 1386 - 1395
  • [2] [Anonymous], NIST REFERENCE FLUID
  • [3] A DYNAMIC PERFORMANCE SIMULATION-MODEL OF FLAT-PLATE SOLAR COLLECTORS FOR A HEAT-PUMP SYSTEM
    ARINZE, EA
    SCHOENAU, GJ
    SOKHANSANJ, S
    ADEFILA, SS
    MUMAH, SM
    [J]. ENERGY CONVERSION AND MANAGEMENT, 1993, 34 (01) : 33 - 49
  • [4] Charters WS, 1980, ANZ SOL EN C MELB AU
  • [5] Analysis of a direct expansion solar assisted heat pump using different refrigerants
    Chata, FBG
    Chaturvedi, SK
    Almogbel, A
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2005, 46 (15-16) : 2614 - 2624
  • [6] Thermal performance of a variable capacity direct expansion solar-assisted heat pump
    Chaturvedi, SK
    Chen, DT
    Kheireddine, A
    [J]. ENERGY CONVERSION AND MANAGEMENT, 1998, 39 (3-4) : 181 - 191
  • [7] THERMAL PERFORMANCE OF A DIRECT EXPANSION SOLAR-ASSISTED HEAT-PUMP
    CHATURVEDI, SK
    SHEN, JY
    [J]. SOLAR ENERGY, 1984, 33 (02) : 155 - 162
  • [8] EGRICAN AN, 1991, ENERG CONVERS MANAGE, V31, P17, DOI 10.1016/0196-8904(91)90101-N
  • [9] Franklin JL, 1977, P FLAT PLAT SOL COLL
  • [10] Performance of evaporator-collector and air collector in solar assisted heat pump dryer
    Hawlader, M. N. A.
    Rahman, S. M. A.
    Jahangeer, K. A.
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2008, 49 (06) : 1612 - 1619