Evaluation of a new nanoparticle-based lateral-flow immunoassay for the exclusion of heparin-induced thrombocytopenia (HIT)

被引:36
|
作者
Sachs, Ulrich J. [1 ]
von Hesberg, Jakob [1 ]
Santoso, Sentot [1 ]
Bein, Gregor [1 ]
Bakchoul, Tamam [1 ]
机构
[1] Univ Giessen, Inst Clin Immunol & Transfus Med, D-35392 Giessen, Germany
关键词
HIT; heparin; diagnostic procedure; immunoassay; ANTI-PF4/HEPARIN ANTIBODIES; PERFORMANCE-CHARACTERISTICS; DIAGNOSIS; IGG; EXPLAIN;
D O I
10.1160/TH-11-06-0390
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Heparin-induced thrombocytopenia (HIT) is an adverse complication of heparin caused by HIT antibodies (abs) that recognise platelet factor 4-heparin (PF4/hep) complexes. Several laboratory tests are available for the confirmation and/or refutation of HIT. A reliable and rapid single-sample test is still pending. It was the objective of this study to evaluate a new lateral-flow immunoassay based on nanoparticle technology. A cohort of 452 surgical and medical patients suspected of having HIT was evaluated. All samples were tested in two IgG-specific ELISAs, in a particle gel immunoassay (PaGIA) and in a newly developed lateral-flow immunoassay (LFI-HIT) as well as in a functional test (HIPA). Clinical pre-test probability was determined using 4T's score. Platelet-activating antibodies were present in 34/452 patients, all of whom had intermediate to high clinical probability. PF4/hep abs were detected in 79, 87, 86, and 63 sera using the four different immunoassays. The negative predictive values (NPV) were 100% for both ELISA tests and LFI-HIT but only 99.2% for PaGIA. There were less false positives (n=29) in the LFI-HIT compared to any other test. Additionally, significantly less time was required to perform LFI-HIT than to perform the other immunoassays. In conclusion, a newly developed lateral-flow assay, LFI-HIT, was capable of identifying all HIT patients in a cohort in a short period of time. Beside an NPV of 100%, the rate of false-positive signals is significantly lower with LFI-HIT than with other immunoassay(s). These performance characteristics suggest a high potency in reducing the risk and costs in patients suspected of having HIT.
引用
收藏
页码:1197 / 1202
页数:6
相关论文
共 41 条
  • [1] Prospective evaluation of a rapid nanoparticle-based lateral flow immunoassay (STic Expert® HIT) for the diagnosis of heparin-induced thrombocytopenia
    Leroux, Dorothee
    Hezard, Nathalie
    Lebreton, Aurelien
    Bauters, Anne
    Suchon, Pierre
    de Maistre, Emmanuel
    Biron, Christine
    Huisse, Marie-Genevieve
    Ternisien, Catherine
    Voisin, Sophie
    Gruel, Yves
    Pouplard, Claire
    BRITISH JOURNAL OF HAEMATOLOGY, 2014, 166 (05) : 774 - 782
  • [2] Real-life evaluation of an automated immunoassay for diagnosis of heparin-induced thrombocytopenia
    Althaus, Karina
    Westphal, Antje
    Strobel, Ulrike
    Bakchoul, Tamam
    Greinacher, Andreas
    THROMBOSIS RESEARCH, 2020, 196 : 400 - 403
  • [3] Evaluation of a rapid and automated heparin-induced thrombocytopenia immunoassay
    Refaai, Majed A.
    Conley, Grace
    Ortel, Thomas L.
    Francis, John L.
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2019, 41 (04) : 478 - 484
  • [4] The Use of Flow Cytometry in the Diagnosis of Heparin-Induced Thrombocytopenia (HIT)
    Malicev, Elvira
    TRANSFUSION MEDICINE REVIEWS, 2020, 34 (01) : 34 - 41
  • [5] Evaluation of a flow cytometric assay for the confirmation of heparin-induced thrombocytopenia
    Malicev, E.
    Kozak, M.
    Rozman, P.
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2016, 38 (03) : 240 - 245
  • [6] Accuracy of the functional, flow cytometer-based Emo-Test HIT Confirm® for the diagnosis of heparin-induced thrombocytopenia
    Brodard, Justine
    Benites, Vincent
    Zeerleder, Denise Stalder
    Nagler, Michael
    THROMBOSIS RESEARCH, 2021, 203 : 22 - 26
  • [7] Iridium oxide (IV) nanoparticle-based lateral flow immunoassay
    Quesada-Gonzalez, Daniel
    Sena-Torralba, Amadeo
    Prio Wicaksono, Wiyogo
    de la Escosura-Muniz, Alfredo
    Ivandini, Tribidasari A.
    Merkoci, Arben
    BIOSENSORS & BIOELECTRONICS, 2019, 132 : 132 - 135
  • [8] Accuracy of a prediction model for heparin-induced thrombocytopenia (HIT): An analysis based on individual patient data
    Garcia Junqueira, Daniela Rezende
    Viana, Thercia Guedes
    Carvalho, Maria das Gracas
    Perini, Edson
    CLINICA CHIMICA ACTA, 2011, 412 (17-18) : 1521 - 1526
  • [9] Effect of heparin administration on heparin-induced thrombocytopenia (HIT) in atherosclerotic New Zealand Rabbit (Oryctolagus cuniculus)
    Nababan, Victor Jesron
    Prasmono, Agung
    Retnowati, Endang
    Legowo, Djoko
    Banjarnahor, Sofna
    BALI MEDICAL JOURNAL, 2020, 9 (03) : 738 - 745
  • [10] Development of a gold nanoparticle-based lateral-flow strip for the detection of dinitolmide in chicken tissue
    Liu, Jie
    Song, Shanshan
    Wu, Aihong
    Wu, Xiaoling
    Xiao, Jing
    Xu, Chuanlai
    ANALYTICAL METHODS, 2020, 12 (25) : 3210 - 3217