Thyroid uptake of liquid versus capsule 131I tracers in hyperthyroid patients treated with liquid 131I

被引:9
|
作者
Rini, JN [1 ]
Vallabhajosula, S [1 ]
Zanzonico, P [1 ]
Hurley, JR [1 ]
Becker, DV [1 ]
Goldsmith, SJ [1 ]
机构
[1] New York Hosp, Cornell Med Ctr, Div Nucl Med, New York, NY 10021 USA
关键词
D O I
10.1089/thy.1999.9.347
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The amount of I-131 used to treat hyperthyroid patients is based in part on the 24-hour thyroid uptake of a diagnostic amount of radioiodine (tracer). We compared the 24-hour uptake of an I-131 tracer administered in liquid or capsule form to the 24-hour uptake of I-131 therapy administered as liquid. Sixty-five hyperthyroid patients with Graves' disease were evaluated and subsequently treated with radioiodine. The liquid group (45 patients) received a liquid I-131 tracer (1.85 MBq [0.05 mCi]) and the capsule group (20 patients) received a capsule I-131 tracer (1.63 MBq [0.044 mCi]). Probe calibration factors were the same for the liquid and capsule I-131 standards. All patients received therapeutic amounts of I-131 [114.7-1106.3 MBq [3.1-29.9 mCi]) in liquid form. Therapy uptakes were obtained using the same collimated uptake probe modified with a calibrated lead shield to attenuate the high photon flux. The mean therapeutic uptake was the same for both groups (58%). The mean diagnostic uptake for the capsule group, however, was less than the mean diagnostic uptake for the liquid group (44% vs. 63%). The mean diagnostic uptake for the capsule group was significantly lower than the mean therapeutic uptake for this group (44% vs. 58%), whereas the mean diagnostic and therapeutic uptakes were similar for the group receiving a liquid tracer (63% vs. 58%). In conclusion, diagnostic uptakes performed with a liquid tracer more accurately predicted liquid therapy uptakes than diagnostic uptakes performed with a capsule tracer. This raises concern about the bioavailability of I-131 in capsule form and has implications for determining the amount of I-131 to administer for therapy. Patients whose I-131 therapy was based on the uptake of a capsule tracer received a higher than intended amount of radiation to the thyroid gland.
引用
收藏
页码:347 / 352
页数:6
相关论文
共 50 条
  • [41] Effect of 131I versus 131I plus antithyroid drug in the management of Graves disease.
    Rong, T
    Ren, KA
    Shi, QW
    JOURNAL OF NUCLEAR MEDICINE, 2002, 43 (05) : 125P - 125P
  • [42] 131I Tositumomab
    Christine R. Culy
    Harriet M. Lamb
    BioDrugs, 2000, 14 : 195 - 202
  • [43] MEASUREMENT OF RADIATION EXPOSURE IN RELATIVES OF THYROID CANCER PATIENTS TREATED WITH 131I
    Ramirez-Garzon, Y. T.
    Avila, O.
    Medina, L. A.
    Gamboa-deBuen, I.
    Rodriguez-Laguna, A.
    Buenfil, A. E.
    Ruiz-Trejo, C.
    Estrada, E.
    Brandan, M. E.
    HEALTH PHYSICS, 2014, 107 (05): : 410 - 416
  • [44] Cellular Uptake and Computational Analysis of [131I]-Xanthine 131 I]-Xanthine and [131I]-Hypoxanthine 131 I]-Hypoxanthine in Human Prostate Cancer Cell Line (LNCaP)
    Wongso, Hendris
    Mahendra, Isa
    Setiadi, Yanuar
    Rattyananda, Badra Sanditya
    Rizaludin, Asep
    Pranisuari, Ni Made Yuktikamura Galih
    Kusumaningrum, Crhisterra Ellen
    MAKARA JOURNAL OF SCIENCE, 2024, 28 (03)
  • [45] 131I radiation exposure and thyroid cancer
    Burki, Talha Khan
    LANCET ONCOLOGY, 2018, 19 (01): : E9 - E9
  • [46] To Use or Not to Use 131I in Thyroid Cancer
    Metter, Darlene
    Phillips, William T.
    Walker, Ronald C.
    Blumhardt, Ralph
    CLINICAL NUCLEAR MEDICINE, 2018, 43 (09) : 670 - 671
  • [47] 131I UTILIZATION BY THYROID TISSUE OF HAGFISH
    TONG, W
    KERKOF, P
    CHAIKOFF, IL
    BIOCHIMICA ET BIOPHYSICA ACTA, 1961, 52 (02) : 299 - &
  • [48] URINARY EXCRETION OF 131I COMPOUNDS AFTER ADMINISTRATION OF 131I THYROXINE
    BLOMSTEDT, B
    ACTA ENDOCRINOLOGICA, 1965, 48 (03): : 481 - +
  • [49] The success of 131I ablation in thyroid cancer patients is significantly reduced after a diagnostic activity of 40 MBq 131I
    Verburg, F. A.
    Verkooijen, R. B. T.
    Stokkel, M. P. M.
    van Isselt, J. W.
    NUKLEARMEDIZIN-NUCLEAR MEDICINE, 2009, 48 (04): : 138 - 142
  • [50] Reconstruction of 131I deposition density in regions of Belarus with estimation of thyroid doses from inhalation of 131I
    Knatko, VA
    Dorozhok, IN
    RADIATION PROTECTION DOSIMETRY, 2001, 93 (01) : 43 - 48