Thyroid uptake of liquid versus capsule 131I tracers in hyperthyroid patients treated with liquid 131I

被引:9
|
作者
Rini, JN [1 ]
Vallabhajosula, S [1 ]
Zanzonico, P [1 ]
Hurley, JR [1 ]
Becker, DV [1 ]
Goldsmith, SJ [1 ]
机构
[1] New York Hosp, Cornell Med Ctr, Div Nucl Med, New York, NY 10021 USA
关键词
D O I
10.1089/thy.1999.9.347
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The amount of I-131 used to treat hyperthyroid patients is based in part on the 24-hour thyroid uptake of a diagnostic amount of radioiodine (tracer). We compared the 24-hour uptake of an I-131 tracer administered in liquid or capsule form to the 24-hour uptake of I-131 therapy administered as liquid. Sixty-five hyperthyroid patients with Graves' disease were evaluated and subsequently treated with radioiodine. The liquid group (45 patients) received a liquid I-131 tracer (1.85 MBq [0.05 mCi]) and the capsule group (20 patients) received a capsule I-131 tracer (1.63 MBq [0.044 mCi]). Probe calibration factors were the same for the liquid and capsule I-131 standards. All patients received therapeutic amounts of I-131 [114.7-1106.3 MBq [3.1-29.9 mCi]) in liquid form. Therapy uptakes were obtained using the same collimated uptake probe modified with a calibrated lead shield to attenuate the high photon flux. The mean therapeutic uptake was the same for both groups (58%). The mean diagnostic uptake for the capsule group, however, was less than the mean diagnostic uptake for the liquid group (44% vs. 63%). The mean diagnostic uptake for the capsule group was significantly lower than the mean therapeutic uptake for this group (44% vs. 58%), whereas the mean diagnostic and therapeutic uptakes were similar for the group receiving a liquid tracer (63% vs. 58%). In conclusion, diagnostic uptakes performed with a liquid tracer more accurately predicted liquid therapy uptakes than diagnostic uptakes performed with a capsule tracer. This raises concern about the bioavailability of I-131 in capsule form and has implications for determining the amount of I-131 to administer for therapy. Patients whose I-131 therapy was based on the uptake of a capsule tracer received a higher than intended amount of radiation to the thyroid gland.
引用
收藏
页码:347 / 352
页数:6
相关论文
共 50 条