Experimental study of the effect of underflow pipe diameter on separation performance of a novel de-foulant hydrocyclone with continuous underflow and reflux function

被引:47
作者
Ni, Long [1 ]
Tian, Jinyi [1 ]
Zhao, Jianing [1 ]
机构
[1] Harbin Inst Technol, Sch Municipal & Environm Engn, Harbin 150090, Peoples R China
关键词
Enhancement separation; Hydrocyclone; Continuous underflow; Foulant; Sewage source heat pump; APEX DIAMETER; FLOW-FIELD; AIR-CORE; ENHANCEMENT; SYSTEMS; RATIO;
D O I
10.1016/j.seppur.2016.07.047
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
In order to solve or relieve the blockage and fouling problems of sewage heat exchangers which have limited the development of sewage source heat pumps for a long time, a novel de-foulant hydrocyclone with continuous underflow and reflux function was proposed. Sand-water experiments and domestic sewage experiments were conducted to study the effect of underflow pipe diameter on the separation performance of the novel de-foulant hydrocyclone. Experimental results suggested that separation efficiency increased with increasing underflow pipe diameter. However, as long as the underflow pipe diameter was not too small (i.e. >5 mm), the novel de-foulant hydrocyclone provided effective separation performance, i.e. the separation efficiency of 94.3-97.2% for the foulant (<4 mm) in the untreated domestic sewage, and 99.96-100% for the sand (75-250 mu m). Compared with the novel de-foulant hydrocyclone with 0 mm underflow pipe diameter (i.e. a closed pipe), which was similar to the conventional hydrocyclone with a closed "grit pot" under its underflow orifice, the novel de-foulant hydrocyclone with continuous underflow and reflux function showed higher separation efficiency (41.6-46.2%) and slightly higher energy consumption (036-1.29 kPa), which could be ignored. In addition, a new concept of separation efficiency (i.e. the comprehensive separation efficiency), which takes into account both separation efficiency and split ratio, was proposed in this paper. Experimental results suggested that only when the ratio of the underflow pipe diameter to the vortex finder diameter was between 12.5% and 25.0%, did the novel de-foulant hydrocyclone have a high comprehensive separation efficiency for foulant (<4 mm), i.e. it had high separation efficiency (92.6-94.3%) and a low split ratio (1.32-2.54%) at the same time. With the increase of the underflow pipe diameter, the split ratio increased quickly and energy consumption increased slightly, whereas the concentration in overflow decreased slightly. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:270 / 279
页数:10
相关论文
共 35 条
[1]  
AHMED AA, 1985, J CHEM TECHNOL BIOT, V35, P395
[2]   Microfluidic device based on a micro-hydrocyclone for particle-liquid separation [J].
Bhardwaj, P. ;
Bagdi, P. ;
Sen, A. K. .
LAB ON A CHIP, 2011, 11 (23) :4012-4021
[3]   Improvements of the cyclone separator performance by down-comer tubes [J].
Bogodage, Sakura Ganegama ;
Leung, A. Y. T. .
JOURNAL OF HAZARDOUS MATERIALS, 2016, 311 :100-114
[4]   Effect of Vortex Finder Diameter on Flow Field and Collection Efficiency of Cyclone Separators [J].
Brar, L. S. ;
Sharma, R. P. ;
Dwivedi, R. .
PARTICULATE SCIENCE AND TECHNOLOGY, 2015, 33 (01) :34-40
[5]   The Effect of Pressure Parameters of a Novel Dynamic Hydrocyclone on the Separation Efficiency and Split Ratio [J].
Chen, Jiawang ;
Hou, Jiwei ;
Li, Gaosen ;
Xu, Chunying ;
Zheng, Binghuan .
SEPARATION SCIENCE AND TECHNOLOGY, 2015, 50 (06) :781-787
[6]   Enhancement of hydrocyclone separation performance by eliminating the air core [J].
Chu, LY ;
Yu, W ;
Wang, GJ ;
Zhou, XT ;
Chen, WM ;
Dai, GQ .
CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2004, 43 (12) :1441-1448
[7]   Numerical and experimental studies of flow field in hydrocyclone with air core [J].
Cui, Bao-yu ;
Wei, De-zhou ;
Gao, Shu-ling ;
Liu, Wen-gang ;
Feng, Yu-qing .
TRANSACTIONS OF NONFERROUS METALS SOCIETY OF CHINA, 2014, 24 (08) :2642-2649
[8]   Optimization of dewatering systems for mineral processing [J].
Galvez, Edelmira D. ;
Cruz, Ronald ;
Robles, Pedro A. ;
Cisternas, Luis A. .
MINERALS ENGINEERING, 2014, 63 :110-117
[9]   A key review of wastewater source heat pump (WWSHP) systems [J].
Hepbasli, Arif ;
Biyik, Emrah ;
Ekren, Orhan ;
Gunerhan, Huseyin ;
Araz, Mustafa .
ENERGY CONVERSION AND MANAGEMENT, 2014, 88 :700-722
[10]   A FURTHER STUDY OF THE HYDRAULIC CYCLONE [J].
KELSALL, DF .
CHEMICAL ENGINEERING SCIENCE, 1953, 2 (06) :254-272