Improved GIRP reference compensation current strategy for hybrid active power filter under unbalanced nonlinear load

被引:0
|
作者
Koochaki, A.
Fathi, S. H.
机构
关键词
D O I
10.1109/IECON.2007.4459984
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Hybrid active power filter has proved to be a useful device to eliminate harmonic currents and to compensate reactive power for nonlinear loads. Several strategies have been proposed to generate the reference compensation current. One of these strategies is GIRP (Generalized Instantaneous Reactive Power Theory) method, which has a good performance in balanced conditions. When file load is unbalanced or the source voltage is distorted, this method is troublesome. This paper presents an Improved GIRP strategy to determine the reference compensation currents of a three phase hybrid active power filler under unbalanced condition. In this method, GIRP strategy is combined with the fundamental positive sequence component of system voltage, which exhibits a better performance compared with the normal GIRP and other similar methods. Proposed method is simulated by MATLAB/SIMULINK. The results are compared with some other strategies; which indicate the proposed strategy Is more effective on compensating of reactive power, harmonic elimination and balancing of unbalanced nonlinear loads.
引用
收藏
页码:1851 / 1856
页数:6
相关论文
共 50 条
  • [1] Modeling of hybrid active power filter for compensation of unbalanced nonlinear load
    Koochaki, A.
    Fathi, S. H.
    Divandari, M.
    2006 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY, VOLS 1-6, 2006, : 1250 - +
  • [2] Adaptive Frequency-Based Reference Compensation Current Control Strategy of Shunt Active Power Filter for Unbalanced Nonlinear Loads
    Chen, Cheng-I
    Lan, Chien-Kai
    Chen, Yeong-Chin
    Chen, Chung-Hsien
    ENERGIES, 2019, 12 (16)
  • [3] An Improved Control Strategy for Hybrid Series Active Filter Dealing with Unbalanced Load
    Nguyen Xuan Tung
    Fujita, Goro
    Horikoshi, Kazuhiro
    IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2011, 6 (04) : 316 - 323
  • [4] A Novel Control Strategy for Shunt Active Power Filter under Nonlinear and Unbalanced Three Phase Load Conditions
    Hao, Shuai
    Fu, Zhouxing
    Wang, Qingliang
    Zheng, Jie
    Zhang, Minglu
    2016 INTERNATIONAL SYMPOSIUM ON COMPUTER, CONSUMER AND CONTROL (IS3C), 2016, : 96 - 98
  • [5] A novel reference compensation current strategy for shunt active power filter control
    Chang, GW
    Shee, TC
    IEEE TRANSACTIONS ON POWER DELIVERY, 2004, 19 (04) : 1751 - 1758
  • [6] Performance Tolerant Control of Shunt Active Power Filter Under Unbalanced Nonlinear Load
    Frifita, K.
    Boussak, M.
    Naamane, A.
    M'Sirdi, N.
    2015 16TH INTERNATIONAL CONFERENCE ON SCIENCES AND TECHNIQUES OF AUTOMATIC CONTROL AND COMPUTER ENGINEERING (STA), 2015, : 278 - 283
  • [7] Comparison of Different Methods of Reference Current Generation for Shunt Active Power Filter Under Balanced And Unbalanced Load Conditions
    Karvekar, Sushil
    Kumbhojkar, Aditi
    PROCEEDINGS OF 2013 INTERNATIONAL CONFERENCE ON CIRCUITS, POWER AND COMPUTING TECHNOLOGIES (ICCPCT 2013), 2013, : 430 - 434
  • [8] Reference Voltage Optimization of a Hybrid Filter for Nonlinear Load Compensation
    Litran, Salvador P.
    Salmeron, Patricio
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2014, 61 (06) : 2648 - 2654
  • [9] A Nonlinear Control Strategy for Hybrid Active Power Filter
    Han Wei
    Zhou Lili
    Wang Dazhi
    Li Yunlu
    2015 27TH CHINESE CONTROL AND DECISION CONFERENCE (CCDC), 2015, : 3596 - 3599
  • [10] An improved synchronous reference frame current control strategy for a photovoltaic grid-connected inverter under unbalanced and nonlinear load conditions
    Naderipour, Amirreza
    Zin, Abdullah Asuhaimi Mohd
    Bin Habibuddin, Mohd Hafiz
    Miveh, Mohammad Reza
    Guerrero, Josep M.
    PLOS ONE, 2017, 12 (02):