Customization and validation of a commercial process simulator for dynamic simulation of Helium liquefier

被引:39
作者
Dutta, Rohan [1 ]
Ghosh, Parthasarathi [1 ]
Chowdhury, Kanchan [1 ]
机构
[1] Indian Inst Technol IIT Kharagpur, Cryogen Engn Ctr, Kharagpur 721302, W Bengal, India
关键词
Dynamic modeling and simulation; Aspen Hysys (R); Parameter estimation; Helium liquefier;
D O I
10.1016/j.energy.2011.03.009
中图分类号
O414.1 [热力学];
学科分类号
摘要
Dynamic simulation of helium plants using Aspen Hysys (R), V7.0 has been validated using cool-down temperature data from two existing helium plants under operation. Fluid properties of helium using 32-term MBWR EOS are found to be numerically unstable and Hepak (R) data has been fed as a table. Metal properties in Aspen Hysys (R) do not have temperature dependence and NIST data has been attached. Expansion engine and turbine characteristic equations also have been successfully incorporated into the process simulator. Unknown plant parameters have been estimated using Least Square Deviation method. The simulation results match closely with the real plant data after these customization and parameter estimations. A real time factor between 8 and 14 has been achieved. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3204 / 3214
页数:11
相关论文
共 24 条
[1]   The use of Argo for validation and tuning of mixed layer models [J].
Acreman, D. M. ;
Jeffery, C. D. .
OCEAN MODELLING, 2007, 19 (1-2) :53-69
[2]  
Aspen Technology Inc., 2010, ASP HYS DYN US GUID
[3]  
Barron RF, 1985, Cryogenic Systems
[4]  
BLACKFORD JE, 1971, CRYOGENIC FUNDAMENTA
[5]   Estimation of soil and grout thermal properties through a TSPEP (two-step parameter estimation procedure) applied to TRT (thermal response test) data [J].
Bozzoli, F. ;
Pagliarini, G. ;
Rainieri, S. ;
Schiavi, L. .
ENERGY, 2011, 36 (02) :839-846
[6]  
Bradu B., 2008, IFAC P VOLUMES, V41, P13265, DOI [10.3182/20080706-5-KR-1001.02247, DOI 10.3182/20080706-5-KR-1001.02247]
[7]   DYNAMIC SIMULATION OF A LARGE SCALE PULSED LOAD HELIUM REFRIGERATOR [J].
Briend, P. ;
Deschildre, C. ;
Icart, Y. ;
Sequeira, S. E. .
ADVANCES IN CRYOGENIC ENGINEERING, VOLS 55A AND 55B, 2010, 1218 :1453-1459
[8]   Dynamic simulation of an helium refrigerator [J].
Deschildre, C. ;
Baffaud, A. ;
Bonnay, P. ;
Briend, P. ;
Girard, A. ;
Poncet, J. M. ;
Roussel, P. ;
Sequeira, S. E. .
ADVANCES IN CRYOGENIC ENGINEERING, VOLS 53A AND 53B, 2008, 985 :475-+
[9]  
DUTTA R, 2010, C 23 NSC OCT 28 30 R
[10]  
GHOSH P, 2010, C 23 NSC OCT 28 30 R