Two-dimensional versus three-dimensional measurement of infant cervical active motion

被引:0
作者
Castle, Kimberly B. [1 ]
Kernozek, Thomas W. [2 ]
Warren, Emily [3 ]
机构
[1] Univ North Georgia, Phys Therapy Dept, Dahlonega, GA 30597 USA
[2] Univ Wisconsin, Dept Hlth Profess Phys Therapy, La Crosse, WI 54601 USA
[3] Aspirus Langlade Hlth & Rehabil, Phys Therapy Dept, Antigo, WI USA
关键词
Infant cervical active motion; congenital muscular torticollis; validity; reliability; kinematic measurement; CONGENITAL MUSCULAR TORTICOLLIS; MUSCLE FUNCTION; RELIABILITY; DETERMINANTS; MANAGEMENT; VALIDITY; RANGE;
D O I
10.1080/09593985.2020.1790069
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Introduction Upright infant active cervical motion (ACM) is difficult to measure accurately by a single examiner. Clinically, physical therapists use visual estimation, which has limited reliability and concurrent validity with gold standards. Consistent, reliable, and valid active motion measurements are needed to document infant status and response to intervention. Purpose Two-dimensional (2D) photo digitization measurements were compared to three-dimensional (3D) motion analysis measures of infant active neck rotation and lateral flexion. Methods Typically-developing infants participated (five boys, nine girls; 3-7.5 months). An experienced pediatric physical therapist and six novice raters marked photographs and used two different 2D methods to measure cervical rotation and three different 2D methods to measure cervical lateral flexion in photographs. To determine the intra- and interrater reliability of the 2D measurement methods and their concurrent validity with the 3D measures, a subset of lateral flexion photos was marked and measured by 14 experienced pediatric physical therapists. Results Novice and experienced examiner measurements of 2D ACM exhibited moderate to excellent intra- and inter-rater reliability. The results of the 2D lateral flexion ACM measurements completed by novice and experienced raters consistently differed from those obtained using the 3D measurement methods. Conclusion The 2D rotation ACM measurement methods were reliable and demonstrated concurrent validity with the gold standard 3D measure. Infants' lateral flexion ACM examined using 2D measures did not correlate with the results of 3D measurements. This indicated that 2D measurements of active infant cervical lateral flexion could not be used as a valid indicators of 3D motion.
引用
收藏
页码:805 / 817
页数:13
相关论文
共 24 条
[1]   Clinical determinants of the outcome of manual stretching in the treatment of congenital muscular torticollis in infants - A prospective study of eight hundred and twenty-one cases [J].
Cheng, JCY ;
Wong, MWN ;
Tang, SP ;
Chen, TMK ;
Shum, SLF ;
Wong, EMC .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2001, 83A (05) :679-687
[2]   The clinical presentation and outcome of treatment of congenital muscular torticollis in infants - A study of 1,086 cases [J].
Cheng, JCY ;
Tang, SP ;
Chen, TMK ;
Wong, MWN ;
Wong, EMC .
JOURNAL OF PEDIATRIC SURGERY, 2000, 35 (07) :1091-1096
[3]   Clinical Feasibility of 2-Dimensional Video Analysis of Active Cervical Motion in Congenital Muscular Torticollis [J].
Christensen, Eric ;
Castle, Kimberly B. ;
Hussey, Erin .
PEDIATRIC PHYSICAL THERAPY, 2015, 27 (03) :276-283
[4]  
Cohen J., 1988, STAT POWER ANAL BEHA
[5]  
Effgen S.K., 2012, Meeting the Physical Therapy Needs of Children
[6]   THE DETERMINANTS OF TREATMENT DURATION FOR CONGENTAL MUSCULAR TORTICOLLIS [J].
EMERY, C .
PHYSICAL THERAPY, 1994, 74 (10) :921-929
[7]   POSTURAL REACTIONS IN INFANTS WITH DOWN-SYNDROME - RELATIONSHIP TO MOTOR MILESTONE DEVELOPMENT AND AGE [J].
HALEY, SM .
PHYSICAL THERAPY, 1986, 66 (01) :17-22
[8]   Physical Therapy Management of Congenital Muscular Torticollis: A 2018 Evidence-Based Clinical Practice Guideline From the APTA Academy of Pediatric Physical Therapy [J].
Kaplan, Sandra L. ;
Coulter, Colleen ;
Sargent, Barbara .
PEDIATRIC PHYSICAL THERAPY, 2018, 30 (04) :240-290
[9]  
Karmel-Ross Karen, 1997, Physical and Occupational Therapy in Pediatrics, V17, P21, DOI 10.1300/J006v17n02_03
[10]   Intra-rater reliability in measuring range of motion in infants with congenital muscular torticollis [J].
Klackenberg, Eva Perbeck ;
Elfving, Britt ;
Haglund-Akerlind, Yvonne ;
Carlberg, Eva Brogren .
EUROPEAN JOURNAL OF PHYSIOTHERAPY, 2005, 7 (02) :84-91