An Integrated Wearable Sensor for Unobtrusive Continuous Measurement of Autonomic Nervous System

被引:45
作者
Mahmud, Md Shaad [1 ]
Fang, Hua [2 ]
Wang, Honggang [3 ]
机构
[1] Univ New Hampshire, Elect & Comp Engn Dept, Durham, NH 03824 USA
[2] Univ Massachusetts, Comp & Informat Sci, Dartmouth, MA 02747 USA
[3] Univ Massachusetts, Elect & Comp Engn Dept, Dartmouth, MA 02747 USA
基金
美国国家科学基金会;
关键词
Drug; electrodermal activity (EDA); emotion; galvanic skin resistance (GSR); heart rate (HR); real-time; ring; stress; wearable; STRESS;
D O I
10.1109/JIOT.2018.2868235
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Advancements in miniaturized electronics and smart sensors combined with a broad platform of smart phones, big data, cloud service, and wireless communication have not only empowered wearable technology, they have also increased users life expectancy. For example, a wearable system provides unobtrusive ambulatory, continuous, ubiquitous health measurement, and real-time solution for patients physical without hampering the natural movement of the wearer. However, the ability to measure one's Autonomic Nervous System (ANS) using wearable biosensors in healthcare applications has been limited due to several challenges related to a lack in wearability, accuracy, reliability, and low-power consumption. In this paper, we presented a novel wearable ring sensor for the continuous measurement of four ANS activities: 1) electrodermal activity; 2) heart rate; 3) skin temperature; and 4) locomotion. Detailed information is given regarding the development of the proposed ring sensor followed by a discussion of the evaluation that was done utilizing the wearable sensor on volunteers to gather data. Specifically, volunteers wore the ring sensor while being simultaneously monitored with real-time telemetry, the sensor values are processed and analyzed. This paper is a continuation and extension of earlier work by the authors. New validation, experimental results, and development of the mobile application have been added to improve the previous system. The experiment demonstrated accurate results, and data were collected from 43 participants of diverse age, body mass, height, and race. Additionally, to evaluate the performance of the developed ring sensor, we compared the results with a state-of-the-art open source device. This paper aims to improve the worn biomedical sensor market, specifically when it comes to size and accuracy of worn sensors.
引用
收藏
页码:1104 / 1113
页数:10
相关论文
共 20 条
[1]  
[Anonymous], 2013, INT J RES ENG ADV TE
[2]   Electrodermal responses to discrete stimuli measured by skin conductance, skin potential, and skin susceptance [J].
Bari, D. S. ;
Aldosky, H. Y. Y. ;
Tronstad, C. ;
Kalvoy, H. ;
Martinsen, O. G. .
SKIN RESEARCH AND TECHNOLOGY, 2018, 24 (01) :108-116
[3]   Real-Time Mobile Detection of Drug Use with Wearable Biosensors: A Pilot Study [J].
Carreiro S. ;
Smelson D. ;
Ranney M. ;
Horvath K.J. ;
Picard R.W. ;
Boudreaux E.D. ;
Hayes R. ;
Boyer E.W. .
Journal of Medical Toxicology, 2015, 11 (1) :73-79
[4]  
Crifaci G, 2013, INT SYMP IMAGE SIG, P499
[5]  
Dedovic K, 2005, J PSYCHIATR NEUROSCI, V30, P319
[6]  
Fang H, 2015, IEEE NETWORK, V29, P6, DOI 10.1109/MNET.2015.7293298
[7]   Pervasive and Unobtrusive Emotion Sensing for Human Mental Health [J].
Guo, Rui ;
Li, Shuangjiang ;
He, Li ;
Gao, Wei ;
Qi, Hairong ;
Owens, Gina .
PROCEEDINGS OF THE 2013 7TH INTERNATIONAL CONFERENCE ON PERVASIVE COMPUTING TECHNOLOGIES FOR HEALTHCARE AND WORKSHOPS (PERVASIVEHEALTH 2013), 2013, :436-439
[8]  
Kim J, 2014, IEEE ENG MED BIO, P6631, DOI 10.1109/EMBC.2014.6945148
[9]   Physiological Signal Monitoring Bed for Infants Based on Load-Cell Sensors [J].
Lee, Won Kyu ;
Yoon, Heenam ;
Han, Chungmin ;
Joo, Kwang Min ;
Park, Kwang Suk .
SENSORS, 2016, 16 (03)
[10]   Investigation on Cardiovascular Risk Prediction Using Physiological Parameters [J].
Lin, Wan-Hua ;
Zhang, Heye ;
Zhang, Yuan-Ting .
COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2013, 2013