Impact desolvation of electrosprayed microdroplets - a new ionization method for mass spectrometry of large biomolecules

被引:53
作者
Aksyonov, SA [1 ]
Williams, P [1 ]
机构
[1] Arizona State Univ, Dept Chem & Biochem, Tempe, AZ 85287 USA
关键词
D O I
10.1002/rcm.470
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Impact desolvation of electrosprayed microdroplets (IDEM) is a new method for producing gas-phase ions of large biomolecules. Analytes are dissolved in an electrolyte solution which is electrosprayed in vacuum, producing highly charged micron and sub-micron sized droplets (microdroplets). These microdroplets are accelerated through potential differences similar to5 - 10 kV to velocities of several km/s and allowed to impact a target surface. The energetic impacts vaporize the droplets and release desolvated gas-phase ions of the analyte molecules. Oligonucleotides (2- to 12-mer) and peptides (bradykinin, neurotensin) yield singly and doubly charged molecular ions with no detectable fragmentation. Because the extent of multiple charging is significantly less than in atmospheric pressure electrospray ionization, and the method produces ions largely free of adducts from solutions of high ionic strength, IDEM has some promise as a method for coupling to liquid chromatographic techniques and for mixture analysis. Ions are produced in vacuum at a flat equipotential surface, potentially allowing efficient ion extraction. Copyright (C) 2001 John Wiley & Sons, Ltd.
引用
收藏
页码:2001 / 2006
页数:6
相关论文
共 10 条
  • [1] CORNETT DS, 1994, RAPID COMMUN MASS SP, V8, P996
  • [2] MASSIVE CLUSTER-IMPACT IONIZATION ON A 4-SECTOR TANDEM MASS-SPECTROMETER
    FABRIS, D
    WU, Z
    FENSELAU, CC
    [J]. JOURNAL OF MASS SPECTROMETRY, 1995, 30 (01): : 140 - 143
  • [3] ION FORMATION FROM CHARGED DROPLETS - ROLES OF GEOMETRY, ENERGY, AND TIME
    FENN, JB
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1993, 4 (07) : 524 - 535
  • [4] Karas M, 2000, J MASS SPECTROM, V35, P1, DOI 10.1002/(SICI)1096-9888(200001)35:1<1::AID-JMS904>3.0.CO
  • [5] 2-0
  • [6] KELVIN, 1895, NATURE, V51, P495
  • [7] Collisional damping interface for an electrospray ionization time-of-flight mass spectrometer
    Krutchinsky, AN
    Chernushevich, IV
    Spicer, VL
    Ens, W
    Standing, KG
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1998, 9 (06) : 569 - 579
  • [8] Loeb L.B., 1958, STATIC ELECTRIFICATI
  • [9] MASSIVE CLUSTER IMPACT MASS-SPECTROMETRY - A NEW DESORPTION METHOD FOR THE ANALYSIS OF LARGE BIOMOLECULES
    MAHONEY, JF
    PEREL, J
    RUATTA, SA
    MARTINO, PA
    HUSAIN, S
    LEE, TD
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1991, 5 (10) : 441 - 445
  • [10] SHOCK-WAVE MODEL FOR SPUTTERING BIOMOLECULES USING MASSIVE CLUSTER IMPACTS
    MAHONEY, JF
    PEREL, J
    LEE, TD
    MARTINO, PA
    WILLIAMS, P
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1992, 3 (04) : 311 - 317