High-contrast 3D neonatal brain imaging with combined T1- and T2-weighted MP-RAGE

被引:12
作者
Conklin, John [1 ,2 ]
Winter, Jeff D. [1 ,2 ]
Thompson, R. Terry [1 ,3 ]
Gelman, Neil [1 ,3 ]
机构
[1] Lawson Hlth Res Inst, Imaging Div, London, ON, Canada
[2] Univ Western Ontario, Dept Med Biophys, London, ON, Canada
[3] Univ Western Ontario, Dept Diagnost Radiol & Nucl Med, London, ON, Canada
关键词
3D MRI; neonatal brain; MP-RAGE; contrast preparation; phase-encoding order;
D O I
10.1002/mrm.21548
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Optimization of magnetization-prepared rapid gradient-echo (MID-RAGE) sequence variations for maximum white matter (WM) versus gray matter (GM) contrast in neonates at 3T was investigated. Numerical simulations were applied to optimize and compare three contrast preparation modules and to assess the effect of phase encoding (PE) order on contrast between WM and thin cortical GM layers. Simulations predict that a new sequence, which combines both T-1- and T-2-weighting into the contrast preparation and utilizes an interleaved elliptical-spiral PE order, should provide the strongest contrast between neonatal WM and cortical GM. This sequence was compared to a conventional MP-RAGE acquisition (i.e., T-1-weighted preparation, centric PE order) for in vivo imaging of seven preterm newborn infants. Regional measurements of the contrast-to-noise ratio (CNR) between WM and GM demonstrated an increase of 50-70% (depending on GM region) using the new sequence, in good agreement with theoretical predictions. This improved contrast resulted in superior WM versus GM discrimination in intensity-based brain tissue segmentations.
引用
收藏
页码:1190 / 1196
页数:7
相关论文
共 24 条
[1]   Rapid T1 mapping using multislice echo planar imaging [J].
Clare, S ;
Jezzard, P .
MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (04) :630-634
[2]  
Cohen MS, 2000, HUM BRAIN MAPP, V10, P204, DOI 10.1002/1097-0193(200008)10:4<204::AID-HBM60>3.0.CO
[3]  
2-2
[4]   A REDUCED POWER SELECTIVE ADIABATIC SPIN-ECHO PULSE SEQUENCE [J].
CONOLLY, S ;
GLOVER, G ;
NISHIMURA, D ;
MACOVSKI, A .
MAGNETIC RESONANCE IN MEDICINE, 1991, 18 (01) :28-38
[5]   Signal-to-noise measurements in magnitude images from NMR phased arrays [J].
Constantinides, CD ;
Atalar, E ;
McVeigh, ER .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (05) :852-857
[6]   Optimization of 3-D MP-RAGE sequences for structural brain imaging [J].
Deichmann, R ;
Good, CD ;
Josephs, O ;
Ashburner, J ;
Turner, R .
NEUROIMAGE, 2000, 12 (01) :112-127
[7]   Spoiling of transverse magnetization in gradient-echo (GRE) imaging during the approach to steady state [J].
Epstein, FH ;
Mugler, JP ;
Brookeman, JR .
MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (02) :237-245
[8]   MULTIPLE FIELD-STRENGTH INVIVO T1 AND T2 FOR CEREBROSPINAL-FLUID PROTONS [J].
HOPKINS, AL ;
YEUNG, HN ;
BRATTON, CB .
MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (02) :303-311
[9]   Quantitative magnetic resonance imaging of brain development in premature and mature newborns [J].
Hüppi, PS ;
Warfield, S ;
Kikinis, R ;
Barnes, PD ;
Zientara, GP ;
Jolesz, FA ;
Tsuji, MK ;
Volpe, JJ .
ANNALS OF NEUROLOGY, 1998, 43 (02) :224-235
[10]  
Inder TE, 1999, ANN NEUROL, V46, P755, DOI 10.1002/1531-8249(199911)46:5<755::AID-ANA11>3.0.CO