Label-free quantification of cystatin C as an improved marker for renal failure

被引:11
作者
Bleher, Oliver [1 ]
Ehni, Markus [1 ]
Gauglitz, Guenter [1 ]
机构
[1] Univ Tubingen, Inst Phys & Theoret Chem IPTC, D-72076 Tubingen, Germany
关键词
Reflectometric interference spectroscopy (RIfS); Optical sensors; Label-free detection; Renal failure; Cystatin C; Biosensor; CREATININE;
D O I
10.1007/s00216-011-5320-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A label-free biosensor has been developed, allowing quantification of cystatin C in human serum. This was achieved by using reflectometric interference spectroscopy as detection method. Cystatin C is a small serum protein that allows detection of renal failure more reliably than established parameters as creatinine. The protein was immobilized on the surface of a glass transducer, forming the sensitive layer of the sensor chip. Based on a binding-inhibition assay, two different types of monoclonal cystatin C antibodies were compared, by their behavior and their obtained working range in buffer and serum as matrix. Both antibodies allowed quantification of the protein in serum as matrix within the required clinical ranges of 0.53-1.02 mg/L. Detected recovery rates are in a range between 84.8% and 116.1%. The developed sensor shows high inner chip reproducibility and low cross-sensitivity.
引用
收藏
页码:349 / 356
页数:8
相关论文
共 21 条
[1]   Two immunoassay formats for fully automated CRP detection in human serum [J].
Albrecht, Christiane ;
Kaeppel, Nina ;
Gauglitz, Guenter .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 391 (05) :1845-1852
[2]  
BRECHT A, 1992, ANALUSIS, V20, P135
[3]   Modulation of nuclear receptor interactions by ligands: Kinetic analysis using surface plasmon resonance [J].
Cheskis, B ;
Freedman, LP .
BIOCHEMISTRY, 1996, 35 (10) :3309-3318
[4]  
DUDLEY RA, 1985, CLIN CHEM, V31, P1264
[5]   An advanced biosensor for the prediction of estrogenic effects of endocrine-disrupting chemicals on the estrogen receptor alpha [J].
Fechner, Peter ;
Proell, Florian ;
Carlquist, Mats ;
Proll, Guenther .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 393 (6-7) :1579-1585
[6]   Adult reference ranges for serum cystatin C, creatinine and predicted creatinine clearance [J].
Finney, H ;
Newman, DJ ;
Price, CP .
ANNALS OF CLINICAL BIOCHEMISTRY, 2000, 37 :49-59
[7]   Direct optical detection in bioanalysis: an update [J].
Gauglitz, Guenter .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 398 (06) :2363-2372
[8]   Point-of-care Laboratory Testing [J].
Gauglitz, Guenter ;
Luppa, Peter B. .
CHEMIE IN UNSERER ZEIT, 2009, 43 (05) :308-318
[9]   Cystatin C - Properties and use as diagnostic marker [J].
Grubb, AO .
ADVANCES IN CLINICAL CHEMISTRY, VOL 35, 2001, 35 :63-99
[10]   Comparison of reflectometric interference spectroscopy with other instruments for label-free optical detection [J].
Hänel, C ;
Gauglitz, G .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 372 (01) :91-100