Numerical observer for cardiac motion assessment using machine learning

被引:5
作者
Marin, Thibault [1 ]
Kalayeh, Mahdi M. [1 ]
Pretorius, P. Hendrik [2 ]
Wernick, Miles N. [1 ]
Yang, Yongyi [1 ]
Brankov, Jovan G. [1 ]
机构
[1] Illions Inst Technol, Med Imaging Res, 3440 S Dearborn St, Chicago, IL 60616 USA
[2] Univ Massachusetts, Med Sch, Dept Radiol, Div Nucl Med, Worcester, MA 01655 USA
来源
MEDICAL IMAGING 2011: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT | 2011年 / 7966卷
基金
美国国家卫生研究院;
关键词
Numerical observer; cardiac motion assessment; motion estimation; deformable mesh model; support vector machine; MATHEMATICAL-MODEL; SPECT; OPTIMIZATION; NOISE;
D O I
10.1117/12.878186
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In medical imaging, image quality is commonly assessed by measuring the performance of a human observer performing a specific diagnostic task. However, in practice studies involving human observers are time consuming and difficult to implement. Therefore, numerical observers have been developed, aiming to predict human diagnostic performance to facilitate image quality assessment. In this paper, we present a numerical observer for assessment of cardiac motion in cardiac-gated SPECT images. Cardiac-gated SPECT is a nuclear medicine modality used routinely in the evaluation of coronary artery disease. Numerical observers have been developed for image quality assessment via analysis of detectability of myocardial perfusion defects (e.g., the channelized Hotelling observer), but no numerical observer for cardiac motion assessment has been reported. In this work, we present a method to design a numerical observer aiming to predict human performance in detection of cardiac motion defects. Cardiac motion is estimated from reconstructed gated images using a deformable mesh model. Motion features are then extracted from the estimated motion field and used to train a support vector machine regression model predicting human scores (human observers' confidence in the presence of the defect). Results show that the proposed method could accurately predict human detection performance and achieve good generalization properties when tested on data with different levels of post-reconstruction filtering.
引用
收藏
页数:7
相关论文
共 24 条
[1]   Human- and model-observer performance in ramp-spectrum noise: effects of regularization and object variability [J].
Abbey, CK ;
Barrett, HH .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2001, 18 (03) :473-488
[2]  
[Anonymous], 2004, Foundations of Image Science
[3]  
[Anonymous], 2000, Pattern Classification
[4]   Spatiotemporal processing of gated cardiac SPECT images using deformable mesh modeling [J].
Brankov, JG ;
Yang, YY ;
Wernick, MN .
MEDICAL PHYSICS, 2005, 32 (09) :2839-2849
[5]   Numerical observer for cardiac motion assessment [J].
Brankov, Jovan G. ;
Marin, Thibault ;
Pretorius, P. Hendrik ;
Yang, Yongyi ;
Wernick, Miles N. .
COMPUTATIONAL IMAGING VIII, 2010, 7533
[6]   Learning a Channelized Observer for Image Quality Assessment [J].
Brankov, Jovan G. ;
Yang, Yongyi ;
Wei, Liyang ;
El Naqa, Issam ;
Wernick, Miles N. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2009, 28 (07) :991-999
[7]  
Eng J., 2006, ROC analysis: Web-based calculator for ROC curves
[8]  
Feng B., 2002, THESIS U UTAH
[9]   EFFECTS OF MYOCARDIAL WALL THICKNESS ON SPECT QUANTIFICATION [J].
GALT, JR ;
GARCIA, EV ;
ROBBINS, WL .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1990, 9 (02) :144-150
[10]  
Gifford HC, 2000, J NUCL MED, V41, P514