Year-round performance assessment of a ground source heat pump with multiple energy piles

被引:43
作者
Cui, Yuanlong [1 ]
Zhu, Jie [1 ]
机构
[1] Univ Nottingham, Dept Architecture & Built Environm, Univ Pk, Nottingham NG7 2RD, England
关键词
Energy piles; GSHP; Ground heat extraction/injection; Soil thermal property; COPs; FINITE-ELEMENT FORMULATION; NUMERICAL-ANALYSIS; TEMPERATURE; EXCHANGERS; OPTIMIZATION; SIMULATION; SYSTEMS; STORAGE; MODEL; TUBE;
D O I
10.1016/j.enbuild.2017.10.033
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The year-round performance of a ground source heat pump (GSHP) with multiple energy piles (EPs) is investigated in this study based on a 3D transient heat transfer model. The GSHP heating and cooling capabilities are simulated and assessed according to thermal energy demands of an air conditioned domestic building, its coefficients of performance (COPs) obtained from numerical analyses and experimental tests are compared and the largest difference between them is less than 8%. The maximum heating and cooling COPs of the GSHP are 3.63 and 4.73 respectively in the first year operation period, and the soil final temperature is lower than its initial temperature, therefore the soil is not capable of recovering by itself due to the building unbalanced heating and cooling loads. Finally, the effects of the soil thermal properties on its temperature and the GSHP COPs are investigated and compared between the first year and tenth year operations, and it is found that the soil with low volumetric heat capacity and high thermal conductivity could achieve a quick temperature recovery. Crown Copyright (C) 2017 Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:509 / 524
页数:16
相关论文
共 49 条
[1]   Efficient finite element formulation for geothermal heating systems. Part II: Transient [J].
Al-Khoury, R. ;
Bonnier, P. G. .
INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN ENGINEERING, 2006, 67 (05) :725-745
[2]   Efficient finite element formulation for geothermal heating systems. Part I: Steady state [J].
Al-Khoury, R ;
Bonnier, PG ;
Brinkgreve, RBJ .
INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN ENGINEERING, 2005, 63 (07) :988-1013
[3]   Efficient numerical modeling of borehole heat exchangers [J].
Al-Khoury, R. ;
Koelbel, T. ;
Schramedei, R. .
COMPUTERS & GEOSCIENCES, 2010, 36 (10) :1301-1315
[4]  
[Anonymous], 2007, GREENLINE HT PLUS
[5]   Finite cylinder-source model for energy pile heat exchangers: Effects of thermal storage and vertical temperature variations [J].
Bandos, Tatyana V. ;
Campos-Celador, Alvaro ;
Lopez-Gonzalez, Luis M. ;
Sala-Lizarraga, Jose M. .
ENERGY, 2014, 78 :639-648
[6]   Energy and geotechnical behaviour of energy piles for different design solutions [J].
Batini, Niccolo ;
Rotta Loria, Alessandro F. ;
Conti, Paolo ;
Testi, Daniele ;
Grassi, Walter ;
Laloui, Lyesse .
APPLIED THERMAL ENGINEERING, 2015, 86 :199-213
[7]   Greenhouse gas emission savings of ground source heat pump systems in Europe: A review [J].
Bayer, Peter ;
Saner, Dominik ;
Bolay, Stephan ;
Rybach, Ladislaus ;
Blum, Philipp .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2012, 16 (02) :1256-1267
[8]   Long-term analysis of two GSHP systems using validated numerical models and proposals to optimize the operating parameters [J].
Capozza, Antonio ;
Zarrella, Angelo ;
De Carli, Michele .
ENERGY AND BUILDINGS, 2015, 93 :50-64
[9]   Efficiency of closed loop geothermal heat pumps: A sensitivity analysis [J].
Casasso, Alessandro ;
Sethi, Rajandrea .
RENEWABLE ENERGY, 2014, 62 :737-746
[10]   Influences on the thermal efficiency of energy piles [J].
Cecinato, Francesco ;
Loveridge, Fleur A. .
ENERGY, 2015, 82 :1021-1033