Determination of eight illegal drugs in human urine by combination of magnetic solid-phase extraction with capillary zone electrophoresis

被引:30
作者
Chen, Ming-Luan [1 ]
Suo, Li-Li [1 ]
Gao, Qiang [1 ]
Feng, Yu-Qi [1 ]
机构
[1] Wuhan Univ, Dept Chem, Key Lab Analyt Chem Biol & Med, Minist Educ, Wuhan 430072, Peoples R China
关键词
CZE; Fe(3)O(4); SiO(2); poly(MAA-co-EDMA); magnetic microspheres; Illegal drugs; Magnetic solid-phase extraction; CHROMATOGRAPHY-MASS SPECTROMETRY; PERFORMANCE LIQUID-CHROMATOGRAPHY; GAS-CHROMATOGRAPHY; ILLICIT DRUGS; ORAL FLUID; MICROEXTRACTION; ABUSE; AMPHETAMINES; COCAINE; HAIR;
D O I
10.1002/elps.201100215
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Using magnetite/silica/poly(methacrylic acid-co-ethylene glycol dimethacrylate) (Fe(3)O(4)/SiO(2)/poly(MAA-co-EDMA)) magnetic microspheres, a rapid and high-throughput magnetic solid-phase extraction coupled with capillary zone electrophoresis (MSPE-CZE) method was developed for the determination of illegal drugs (ketamine, amphetamines, opiates, and metabolites). The MSPE of target analytes could be completed within 2 min, and the eight target analytes could be baseline separated within 15 min by CZE with 30 mM phosphate buffer solution (PBS, pH 2.0) containing 15% v/v ACN as background electrolyte. Furthermore, hydrodynamic injection with field-amplified sample stacking (FASS) was employed to enhance the sensitivity of this MSPE-CZE method. Under such optimal conditions, the limits of detection for the eight target analytes ranged from 0.015 to 0.105 mu g/mL. The application feasibility of MSPE-CZE in illegal drugs monitoring was demonstrated by analyzing urine samples, and the recoveries of target drugs for the spiked sample ranging from 85.4 to 110.1%. The method reproducibility was tested by evaluating the intra- and interday precisions, and relative standard deviations of < 10.3 and 12.4%, respectively, were obtained. To increase throughput of the analysis, a home-made MSPE array that has potential application to the treatment of 96 samples simultaneously was used.
引用
收藏
页码:2099 / 2106
页数:8
相关论文
共 30 条
  • [1] Overview of the status and applications of capillary electrophoresis to the analysis of small molecules
    Altria, KD
    Elder, D
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2004, 1023 (01) : 1 - 14
  • [2] Capillary electrophoresis for the analysis of small-molecule pharmaceuticals
    Altria, Kevin
    Marsh, Alex
    Sanger-van de Griend, Carl
    [J]. ELECTROPHORESIS, 2006, 27 (12) : 2263 - 2282
  • [3] CEC-ESI ion trap MS of multiple drugs of abuse
    Aturki, Zeineb
    D'Orazio, Giovanni
    Rocco, Anna
    Bortolotti, Federica
    Gottardo, Rossella
    Tagliaro, Franco
    Fanali, Salvatore
    [J]. ELECTROPHORESIS, 2010, 31 (07) : 1256 - 1263
  • [4] Solid-phase microextraction for the determination of cocaine and cocaethylene inhuman hair by gas chromatography-mass spectrometry
    Bermejo, AM
    López, P
    Alvarez, I
    Tabernero, MJ
    Fernández, P
    [J]. FORENSIC SCIENCE INTERNATIONAL, 2006, 156 (01) : 2 - 8
  • [5] Automated Online Solid Phase Extraction Ultra High Performance Liquid Chromatography Method Coupled with Tandem Mass Spectrometry for Determination of Forty-Two Therapeutic Drugs and Drugs of Abuse in Human Urine
    Chiuminatto, Ugo
    Gosetti, Fabio
    Dossetto, Paolo
    Mazzucco, Eleonora
    Zampieri, Davide
    Robotti, Elisa
    Gennaro, Maria Carla
    Marengo, Emilio
    [J]. ANALYTICAL CHEMISTRY, 2010, 82 (13) : 5636 - 5645
  • [6] Solvent-enhanced microwave-assisted derivatization following solid-phase extraction combined with gas chromatography-mass spectrometry for determination of amphetamines in urine
    Chung, Li-Wen
    Liu, Geng-Jhih
    Li, Zu-Guang
    Chang, Yan-Zin
    Lee, Maw-Rong
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 874 (1-2): : 115 - 118
  • [7] A hybrid liquid chromatography-mass spectrometry strategy in a forensic laboratory for opioid, cocaine and amphetamine classes in human urine using a hybrid linear ion trap-triple quadrupole mass spectrometer
    Dowling, Geraldine
    Regan, Liam
    Tierney, Julie
    Nangle, Michael
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (44) : 6857 - 6866
  • [8] Analysis of amphetamine-type substances by capillary zone electrophoresis using capacitively coupled contactless conductivity detection
    Epple, Rochelle
    Blanes, Lucas
    Beavis, Alison
    Roux, Claude
    Doble, Philip
    [J]. ELECTROPHORESIS, 2010, 31 (15) : 2608 - 2613
  • [9] One-step liquid-liquid extraction of cocaine from urine samples for gas chromatographic analysis
    Farina, M
    Yonamine, M
    Silva, OA
    [J]. FORENSIC SCIENCE INTERNATIONAL, 2002, 127 (03) : 204 - 207
  • [10] Rapid magnetic solid-phase extraction based on magnetite/silica/poly(methacrylic acid-co-ethylene glycol dimethacrylate) composite microspheres for the determination of sulfonamide in milk samples
    Gao, Qiang
    Luo, Dan
    Ding, Jun
    Feng, Yu-Qi
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (35) : 5602 - 5609