Experimental study of the film thickness in the dehumidifier of a liquid desiccant air conditioning system

被引:22
作者
Luo, Yimo [1 ]
Wang, Meng [1 ,2 ]
Yang, Hongxing [1 ]
Lu, Lin [1 ]
Peng, Jinqing [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Bldg Serv Engn, RERG, Hong Kong, Hong Kong, Peoples R China
[2] Hunan Univ, Coll Civil Engn, Changsha 410082, Hunan, Peoples R China
关键词
Film thickness; Dehumidifier; Experimental study; Statistical study; MASS-TRANSFER; FLOW; RESISTANCE; DYNAMICS; WAVES;
D O I
10.1016/j.energy.2015.02.091
中图分类号
O414.1 [热力学];
学科分类号
摘要
A liquid desiccant air conditioning system is one possible substitute for the high energy consumption of the conventional system. The dehumidifier performance is of great importance as it is the key component of such systems. Film thickness plays a vital role in determining the heat and mass transfer performance of a falling film dehumidifier. However, no experimental studies on the liquid film thickness of the dehumidifier within liquid desiccant air conditioning systems have been conducted. Therefore, the film thickness of Lid(solution flow in a single channel dehumidifier is chosen to be investigated in this study. It was found that the mean film thickness without air flow followed the same trend as that predicted by the Nusselt relation, but was about 20% greater. The opposite air flow exerted a shear force on the liquid film to increase the mean film thickness non-linearly. The mean and changing film thickness over time are studied and comparisons made between the lower and upper points of the film. When no air flow existed, the mean film thickness at the lower point was found to be about 10.7%-16.3% thicker than at the upper point. An increase of the air velocity enhanced the wave at both the upper and lower points. The falling film statistical characteristics are also analyzed, and the probability density of the film thickness was found to effectively describe the flow condition. It was also shown that an increase in both the solution flow rate and air velocity enhanced the surface wave velocity. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:239 / 246
页数:8
相关论文
共 31 条
[1]   Predictions of moisture removal rate and dehumidification effectiveness for structured liquid desiccant air dehumidifier [J].
Abdul-Wahab, SA ;
Zurigat, YH ;
Abu-Arabi, MK .
ENERGY, 2004, 29 (01) :19-34
[2]  
[Anonymous], 2013, HONG KONG EN END US
[3]   An experimental study of structured packing dehumidifier/regenerator operating with liquid desiccant [J].
Bassuoni, M. M. .
ENERGY, 2011, 36 (05) :2628-2638
[4]   Time and spatially resolved measurements of interfacial waves in vertical annular flow [J].
Belt, R. J. ;
Van't Westende, J. M. C. ;
Prasser, H. M. ;
Portela, L. M. .
INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 2010, 36 (07) :570-587
[5]   Measurement of liquid film thickness and the determination of spin-up radius on a rotating disc using an electrical resistance technique [J].
Burns, JR ;
Ramshaw, C ;
Jachuck, RJ .
CHEMICAL ENGINEERING SCIENCE, 2003, 58 (11) :2245-2253
[6]   STATISTICAL CHARACTERISTICS OF THIN, WAVY FILMS .3. STRUCTURE OF LARGE WAVES AND THEIR RESISTANCE TO GAS-FLOW [J].
CHU, KJ ;
DUKLER, AE .
AICHE JOURNAL, 1975, 21 (03) :583-593
[7]   ASSESSMENT OF THE NEW AND EXISTING CORRELATIONS FOR LAMINAR AND TURBULENT FILM CONDENSATIONS ON A VERTICAL SURFACE [J].
CHUN, MH ;
KIM, KT .
INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 1990, 17 (04) :431-441
[8]   Artificial neural network analysis of liquid desiccant dehumidification system [J].
Gandhidasan, P. ;
Mohandes, M. A. .
ENERGY, 2011, 36 (02) :1180-1186
[9]   Experimental study on axial development of liquid film in vertical upward annular two-phase flow [J].
Hazuku, Tatsuya ;
Takamasa, Tomoji ;
Matsumoto, Yoichiro .
INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 2008, 34 (02) :111-127
[10]   DIFFUSION OF DISSOLVED GASES IN LIQUIDS [J].
HIMMELBLAU, DM .
CHEMICAL REVIEWS, 1964, 64 (05) :527-&