Accuracy of Noninvasive and Invasive Point-of-Care Total Blood Hemoglobin Measurement in an Outpatient Setting

被引:37
|
作者
Raikhel, Marina [1 ]
机构
[1] Torrance Clin Res Inst, Lomita, CA 90717 USA
关键词
hemoglobin; anemia; pulse oximetry; outpatients; point-of-care technology; monitoring; physiologic; SPINE SURGERY; SPHB;
D O I
10.3810/pgm.2012.07.2584
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: The purpose of this study was to determine the accuracy of noninvasive hemoglobin measurement using pulse CO-oximetry (Pronto (R) SpHb (R), Masimo Corp.) and a commonly used, invasive, point-of-care, automated spectrophotometer (HemoCue 201+(R), HeinoCue, Inc.), in comparison with hemoglobin measurements obtained from a laboratory hematology analyzer (measuring total blood hemoglobin) in the outpatient setting. Methods: Adult patients presenting to an outpatient research clinic were tested for total blood hemoglobin measurement by 3 methods: noninvasive pulse CO-oximetry (SpHb (R)), finger-stick blood sample on a point-of-care device, and venous sample on a laboratory hematology analyzer (reference device). Bias and standard deviation (SD) of SpHb (R) and HemoCue 201+(R) compared with the values obtained with the laboratory hematology analyzer were calculated and Bland-Altman graphs were generated. Results: Samples from 152 subjects were assessed (average age, 46 years; 69% female). The bias +/- SD compared with the reference method was -0.5 +/- 1.0 g/dL for SpHb (R) and 0.3 +/- 1.0 g/dL for HemoCue 201+(R). The Bland-Altman plots assessing agreement of the test methods to the reference method had limits of agreement of -2.5 to 1.5 g/dL for SpHb (R) and -1.7 to 2.3 g/dL for HemoCue 201+(R). A noninvasive measurement could not be obtained in 4 subjects after 2 attempts (2.5% failure rate), whereas the HemoCue 201+(R) measurements were obtained for all subjects. Conclusion: Noninvasive SpHb (R) testing had bias and SD similar to those of HemoCue 201+(R). Because SpHb (R) measurement is noninvasive, it may offer additional patient and provider benefits.
引用
收藏
页码:250 / 255
页数:6
相关论文
共 50 条
  • [1] Accuracy of Noninvasive and Invasive Point-of-Care Hemoglobin Measurement in the Emergency Department
    Wager, A.
    Thomas, A. W.
    Sewatsky, T. P.
    Boas, S.
    O'keefe, M. F.
    Freeman, K.
    ANNALS OF EMERGENCY MEDICINE, 2013, 62 (04) : S41 - S41
  • [2] Accuracy of noninvasive hemoglobin and invasive point-of-care hemoglobin testing compared with a laboratory analyzer
    Shah, N.
    Osea, E. A.
    Martinez, G. J.
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2014, 36 (01) : 56 - 61
  • [3] NONINVASIVE AND INVASIVE POINT-OF-CARE HEMOGLOBIN TESTING FOR BLOOD DONOR QUALIFICATION
    Corradino, M.
    Whitley, P. H.
    Linda, L.
    Graminske, S. J.
    Straus, T.
    Maes, L. A.
    VOX SANGUINIS, 2013, 105 : 110 - 110
  • [4] Comparison of noninvasive and invasive point-of-care testing methods with reference method for hemoglobin measurement
    Avcioglu, Gamze
    Nural, Cemil
    Yilmaz, Fatma Meric
    Baran, Pervin
    Erel, Ozcan
    Yilmaz, Gulsen
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2018, 32 (03)
  • [5] Accuracy of a point-of-care blood lactate measurement device in a prehospital setting
    Walther, Louise Houlberg
    Zegers, Floor
    Nybo, Mads
    Mogensen, Christian Backer
    Christensen, Erika Frischknecht
    Lassen, Annmarie Touborg
    Mikkelsen, Soren
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2022, 36 (06) : 1679 - 1687
  • [6] Accuracy of a point-of-care blood lactate measurement device in a prehospital setting
    Louise Houlberg Walther
    Floor Zegers
    Mads Nybo
    Christian Backer Mogensen
    Erika Frischknecht Christensen
    Annmarie Touborg Lassen
    Søren Mikkelsen
    Journal of Clinical Monitoring and Computing, 2022, 36 : 1679 - 1687
  • [7] Blood glucose: Measurement in the point-of-care setting
    Kiechle, FL
    Main, RI
    LABORATORY MEDICINE, 2000, 31 (05) : 276 - 282
  • [8] Diagnostic Accuracy of a Bacterial and Viral Biomarker Point-of-Care Test in the Outpatient Setting
    Shapiro, Nathan, I
    Filbin, Michael R.
    Hou, Peter C.
    Kurz, Michael C.
    Han, Jin H.
    Aufderheide, Tom P.
    Ward, Michael A.
    Pulia, Michael S.
    Birkhahn, Robert H.
    Diaz, Jorge L.
    Hughes, Teena L.
    Harsch, Manya R.
    Bell, Annie
    Suarez-Cuervo, Catalina
    Sambursky, Robert
    JAMA NETWORK OPEN, 2022, 5 (10) : E2234588
  • [9] Point-of-care coagulation testing in the outpatient setting
    Mackie, Ian
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2007, 29 : 30 - 31
  • [10] Invasive and non-invasive point-of-care testing and point-of-care monitoring of the hemoglobin concentration in human blood - how accurate are the data?
    Dietzel, Frank
    Dieterich, Peter
    Doerries, Frank
    Gehring, Hartmut
    Wegerich, Philipp
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2019, 64 (05): : 495 - 506