A new optimized method for the determination of fibrin clot permeability

被引:11
作者
Sjoland, JA
机构
[1] Ribe Cty Hosp, Dept Clin Biochem, DK-6700 Esbjerg, Denmark
[2] Univ So Denmark, Dept Thrombosis Res, Odense, Denmark
关键词
coefficient of variation; fibrin clot permeability; fibrin structure; fibrinogen; plasma; reference interval; reproducibility;
D O I
10.1097/01.mbc.0000187264.02317.e3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The measurement of fibrin clot permeability is important in the investigation of fibrin clot characteristics. A major disadvantage of the standard measurement techniques is that they are time consuming as they require constant adjustments and monitoring. Presented here is a new method that is easy to perform and does not need continuous adjustments. In addition, the supervision required during the measurement is greatly minimized. When performing the measurement in quadruple, the intra-run coefficient of variation is 11.7%, which is comparable with other reported methods. A (5.1-13.1) X 10(-9) cm(2) reference interval of the permeability coefficient (K-S) among 22 healthy volunteers was established.
引用
收藏
页码:579 / 583
页数:5
相关论文
共 16 条
  • [1] The factor XIII V34L polymorphism accelerates thrombin activation of factor XIII and affects cross-linked fibrin structure
    Ariens, RAS
    Philippou, H
    Nagaswami, C
    Weisel, JW
    Lane, DA
    Grant, PJ
    [J]. BLOOD, 2000, 96 (03) : 988 - 995
  • [2] Role of factor XIII in fibrin clot formation and effects of genetic polymorphisms
    Ariëns, RAS
    Lai, TS
    Weisel, JW
    Greenberg, CS
    Grant, PJ
    [J]. BLOOD, 2002, 100 (03) : 743 - 754
  • [3] FIBRIN GEL STRUCTURE AND CLOTTING TIME
    BLOMBACK, B
    OKADA, M
    [J]. THROMBOSIS RESEARCH, 1982, 25 (1-2) : 51 - 70
  • [4] NATIVE FIBRIN GEL NETWORKS OBSERVED BY 3D MICROSCOPY, PERMEATION AND TURBIDITY
    BLOMBACK, B
    CARLSSON, K
    HESSEL, B
    LILJEBORG, A
    PROCYK, R
    ASLUND, N
    [J]. BIOCHIMICA ET BIOPHYSICA ACTA, 1989, 997 (1-2) : 96 - 110
  • [5] MASS-LENGTH RATIO OF FIBRIN FIBERS FROM GEL-PERMEATION AND LIGHT-SCATTERING
    CARR, ME
    SHEN, LL
    HERMANS, J
    [J]. BIOPOLYMERS, 1977, 16 (01) : 1 - 15
  • [6] Influence of γ′ fibrinogen splice variant on fibrin physical properties and fibrinolysis rate
    Collet, JP
    Nagaswami, C
    Farrell, DH
    Montalescot, G
    Weisel, JW
    [J]. ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 2004, 24 (02) : 382 - 386
  • [7] Collet JP, 1999, THROMB HAEMOSTASIS, V82, P1482
  • [8] Fatah K, 1996, THROMB HAEMOSTASIS, V76, P535
  • [9] Modifications of flow measurement to determine fibrin gel permeability and the preliminary use in research and clinical materials
    He, S
    Cao, H
    Antovic, A
    Blombäck, M
    [J]. BLOOD COAGULATION & FIBRINOLYSIS, 2005, 16 (01) : 61 - 67
  • [10] Increased plasma fibrin gel porosity in patients with Type I diabetes during continuous subcutaneous insulin infusion
    Jörneskog, G
    Hansson, LO
    Wallen, NH
    Yngen, M
    Blombäck, M
    [J]. JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2003, 1 (06) : 1195 - 1201