Right- and left-sided Mallinckrodt double-lumen tubes have identical clinical performance

被引:28
作者
Ehrenfeld, Jesse M. [1 ]
Walsh, John L. [1 ]
Sandberg, Warren S. [1 ]
机构
[1] Harvard Univ, Massachusetts Gen Hosp, Sch Med, Dept Anesthesia & Crit Care, Boston, MA 02114 USA
关键词
D O I
10.1213/ane.0b013e31816f24d5
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
BACKGROUND: Left-sided double-lumen tubes are perceived to be safer than right-sided tubes, because they may be less prone to malposition. If this is true, then the incidence and severity of hypoxemia, hypercapnea, and high airway pressures should be higher for right-sided tubes during thoracic surgery than for left-sided tubes. METHODS: We retrospectively reviewed thoracic surgical anesthetics between April 15, 2003, and December 31, 2004, using an automated anesthesia information management system. The system automatically records pulse oximetry, end-tidal carbon dioxide, and peak inspiratory pressure data every 30 s. Side of surgery and double-lumen tube placement are also documented. We compared the frequency of right- and left-sided Mallinckrodt tube use by thoracic anesthesiologists. Next, we examined the incidence, duration, and severity of hypoxemia (Spo(2) <90%), hypercapnea (Etco(2) >45 mm Hg) and high airway pressures (peak inspiratory pressure >35 cm H(2)O) for lung and chest wall surgery patients. Group counts and means were compared by standard statistical methods. RESULTS: Right- (n = 241) and left- (n = 450) sided tubes were almost exclusively used on the side contralateral to surgery. There were no differences in the incidence or duration of hypoxemia, hypercarbia, or high airway pressures. There was a small but significant increase in Etco(2) for patients having left lung ventilation. CONCLUSIONS: The supposition that left-sided double-lumen tubes are safer than right-sided tubes when intraoperative hypoxemia, hypercapnea, and high airway pressures are used as criteria for safety is not supported by our data comparing the two types of tubes from one manufacturer.
引用
收藏
页码:1847 / 1852
页数:6
相关论文
共 15 条
[1]   MARGIN OF SAFETY IN POSITIONING MODERN DOUBLE-LUMEN ENDOTRACHEAL-TUBES [J].
BENUMOF, JL ;
PARTRIDGE, BL ;
SALVATIERRA, C ;
KEATING, J .
ANESTHESIOLOGY, 1987, 67 (05) :729-738
[2]   Left double-lumen tubes: Clinical experience with 1,170 patients [J].
Brodsky, JB ;
Lemmens, HJM .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2003, 17 (03) :289-298
[3]   The incidence of right upper-lobe collapse when comparing a right-sided double-lumen tube versus a modified left double-lumen tube for left-sided thoracic surgery [J].
Campos, JH ;
Massa, FC ;
Kernstine, KH .
ANESTHESIA AND ANALGESIA, 2000, 90 (03) :535-540
[4]   Con: Right-sided double-lumen endotracheal tubes should not be routinely used in thoracic surgery [J].
Cohen, E .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2002, 16 (02) :249-252
[5]   DIFFERENCES BETWEEN HANDWRITTEN AND AUTOMATIC BLOOD-PRESSURE RECORDS [J].
COOK, RI ;
MCDONALD, JS ;
NUNZIATA, E .
ANESTHESIOLOGY, 1989, 71 (03) :385-390
[6]  
Hurford W E, 1993, J Cardiothorac Vasc Anesth, V7, P517, DOI 10.1016/1053-0770(93)90305-5
[7]   Role of fiberoptic bronchoscopy in conjunction with the use of double-lumen tubes for thoracic anesthesia - A prospective study [J].
Klein, U ;
Karzai, W ;
Bloos, F ;
Wohlfarth, M ;
Gottschall, R ;
Fritz, H ;
Gugel, M ;
Seifert, A .
ANESTHESIOLOGY, 1998, 88 (02) :346-350
[8]   AUTOMATED CHARTING OF PHYSIOLOGICAL VARIABLES IN ANESTHESIA - A QUANTITATIVE COMPARISON OF AUTOMATED VERSUS HANDWRITTEN ANESTHESIA RECORDS [J].
LEROU, JGC ;
DIRKSEN, R ;
NIJHUIS, GMM ;
CRUL, JF .
JOURNAL OF CLINICAL MONITORING, 1988, 4 (01) :37-47
[9]  
McKenna M J, 1988, J Cardiothorac Anesth, V2, P734, DOI 10.1016/0888-6296(88)90096-8
[10]   The margin of safety of a left double-lumen tracheobronchial tube depends on the length of the bronchial cuff and tip [J].
Partridge, L. ;
Russell, W. J. .
ANAESTHESIA AND INTENSIVE CARE, 2006, 34 (05) :618-620