Continuously moving table MRI with SENSE: Application in peripheral contrast enhanced MR angiography

被引:15
作者
Hu, HH [1 ]
Madhuranthakam, AJ [1 ]
Kruger, DG [1 ]
Glockner, JF [1 ]
Riederer, SJ [1 ]
机构
[1] Mayo Clin, Coll Med, Dept Radiol, Magnet Resonance Lab, Rochester, MN 55905 USA
关键词
continuously moving table; parallel imaging; SENSE; peripheral contrast-enhanced MRA; gradient non-linearity correction;
D O I
10.1002/mrm.20639
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
An integration of SENSitivity Encoding (SENSE) with continuously moving table (CMT) MRI for extended field-of-view (FOV) acquisitions is described. In this work, the approach in which receiver coils are attached to the object and move in synchrony with the scanner table is considered. Technical issues dealing with the implementation of SENSE-CMT are addressed, including coil calibration, correction for non-uniform magnetic gradients, and specific reconstruction steps. An explanation of combining SENSE with gradient non-linearity correction is given, as the latter becomes necessary in CMT acquisitions where a large sampling FOV is used. It is hypothesized that SENSE can provide at least a 2-fold improvement in lateral spatial resolution compared to non-accelerated CMT acquisitions. The hypothesis is tested in phantoms, where the effectiveness of both SENSE and gradient non-linearity correction to improve spatial resolution is shown. The SENSE-CMT technique is further demonstrated in vivo with contrast-enhanced MR angiography of the peripheral vasculature.
引用
收藏
页码:1025 / 1031
页数:7
相关论文
共 21 条
[1]   Gadolinium-enhanced three-dimensional MR angiography of the entire aorta and iliac arteries with dynamic manual table translation [J].
Earls, JP ;
DeSena, S ;
Bluemke, DA .
RADIOLOGY, 1998, 209 (03) :844-849
[2]   Floating table isotropic projection (FLIPR) acquisition: A time-resolved 3D method for extended field-of-view MRI during continuous table motion [J].
Fain, SB ;
Browning, FJ ;
Polzin, JA ;
Du, J ;
Zhou, Y ;
Block, WF ;
Grist, TM ;
Mistretta, CA .
MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (05) :1093-1102
[3]  
FAUTZ HP, 2001, P 9 SCI M ISMRM GLAS, V9, P233
[4]  
Glover G., 1986, US Patent, Patent No. [4,591,789., 4591789, 4,591,789]
[5]   The SENSE ghost: Field-of-view restrictions for SENSE imaging [J].
Goldfarb, JW .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 20 (06) :1046-1051
[6]   Improved mufti-station peripheral MR angiography with a dedicated vascular coil [J].
Goyen, M ;
Ruehm, SG ;
Barkhausen, J ;
Kröger, K ;
Ladd, ME ;
Truemmler, KH ;
Bosk, S ;
Requardt, M ;
Reykowski, A ;
Debatin, JF .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2001, 13 (03) :475-480
[7]   Field-of-view limitations in parallel imaging [J].
Griswold, MA ;
Kannengiesser, S ;
Heidemann, RM ;
Wang, JM ;
Jakob, PM .
MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (05) :1118-1126
[8]  
HU H, 2004, P 12 SCI M ISMRM KY, V12, P325
[9]   Continuously moving table SENSE imaging [J].
Keupp, J ;
Aldefeld, B ;
Börnert, P .
MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (01) :217-220
[10]  
KEUPP J, 2004, P 12 SCI M ISMRM KY, V12, P324