Modelling the risk of airborne infectious disease using exhaled air

被引:46
作者
Issarow, Chacha M. [1 ]
Mulder, Nicola [1 ]
Wood, Robin [2 ]
机构
[1] Univ Cape Town, Fac Hlth Sci, Inst Infect Dis & Mol Med, Computat Biol Grp, ZA-7700 Rondebosch, South Africa
[2] Univ Cape Town, Fac Hlth Sci, Inst Infect Dis & Mol Med, Desmond Tutu HIV Ctr, ZA-7700 Rondebosch, South Africa
基金
英国医学研究理事会;
关键词
Infectious particles; Mathematical model; Threshold level; Deposition fraction; TRANSMISSION; VENTILATION;
D O I
10.1016/j.jtbi.2015.02.010
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
In this paper we develop and demonstrate a flexible mathematical model that predicts the risk of airborne infectious diseases, such as tuberculosis under steady state and non-steady state conditions by monitoring exhaled air by infectors in a confined space. In the development of this model, we used the rebreathed air accumulation rate concept to directly determine the average volume fraction of exhaled air in a given space. From a biological point of view, exhaled air by infectors contains airborne infectious particles that cause airborne infectious diseases such as tuberculosis in confined spaces. Since not all infectious particles can reach the target infection site, we took into account that the infectious particles that commence the infection are determined by respiratory deposition fraction, which is the probability of each infectious particle reaching the target infection site of the respiratory tracts and causing infection. Furthermore, we compute the quantity of carbon dioxide as a marker of exhaled air, which can be inhaled in the room with high likelihood of causing airborne infectious disease given the presence of infectors. We demonstrated mathematically and schematically the correlation between TB transmission probability and airborne infectious particle generation rate, ventilation rate, average volume fraction of exhaled air, TB prevalence and duration of exposure to infectors in a confined space. (C) 2015 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:100 / 106
页数:7
相关论文
共 18 条
[1]   Modeling the Role of Public Transportation in Sustaining Tuberculosis Transmission in South Africa [J].
Andrews, Jason R. ;
Morrow, Carl ;
Wood, Robin .
AMERICAN JOURNAL OF EPIDEMIOLOGY, 2013, 177 (06) :556-561
[2]  
Beggs CB, 2003, INT J TUBERC LUNG D, V7, P1015
[3]  
Emmerich S.J., 2001, STATE OF THE ART REV
[4]   Using a mathematical model to evaluate the efficacy of TB control measures [J].
Gammaitoni, L ;
Nucci, MC .
EMERGING INFECTIOUS DISEASES, 1997, 3 (03) :335-342
[5]   Ventilation Control of Indoor Transmission of Airborne Diseases in an Urban Community [J].
Gao, Xiaolei ;
Li, Yuguo ;
Leung, Gabriel M. .
INDOOR AND BUILT ENVIRONMENT, 2009, 18 (03) :205-218
[6]   Role of ventilation in airborne transmission of infectious agents in the built environment - a multidisciplinary systematic review [J].
Li, Y. ;
Leung, G. M. ;
Tang, J. W. ;
Yang, X. ;
Chao, C. Y. H. ;
Lin, J. Z. ;
Lu, J. W. ;
Nielsen, P. V. ;
Niu, J. ;
Qian, H. ;
Sleigh, A. C. ;
Su, H. -J. J. ;
Sundell, J. ;
Wong, T. W. ;
Yuen, P. L. .
INDOOR AIR, 2007, 17 (01) :2-18
[7]  
LOUDON RG, 1967, AM REV RESPIR DIS, V95, P435
[8]   Natural ventilation reduces high TB transmission risk in traditional homes in rural KwaZulu-Natal, South Africa [J].
Lygizos, Melissa ;
Shenoi, Sheela V. ;
Brooks, Ralph P. ;
Bhushan, Ambika ;
Brust, James C. M. ;
Zelterman, Daniel ;
Deng, Yanhong ;
Northrup, Veronika ;
Moll, Anthony P. ;
Friedland, Gerald H. .
BMC INFECTIOUS DISEASES, 2013, 13
[9]  
Murray M, 2011, Int J Tuberc Lung Dis, V15 Suppl 2, P64, DOI 10.5588/ijtld.10.0535
[10]   Mathematical models for assessing the role of airflow on the risk of airborne infection in hospital wards [J].
Noakes, Catherine J. ;
Sleigh, P. Andrew .
JOURNAL OF THE ROYAL SOCIETY INTERFACE, 2009, 6 :S791-S800