Deep Learning Driven Noise Reduction for Reduced Flux Computed Tomography

被引:11
作者
Alsamadony, Khalid L. [1 ]
Yildirim, Ertugrul U. [2 ]
Glatz, Guenther [1 ]
Bin Waheed, Umair [1 ]
Hanafy, Sherif M. [1 ]
机构
[1] King Fahd Univ Petr & Minerals KFUPM, Coll Petr Engn & Geosci CPG, Dhahran 31261, Saudi Arabia
[2] Middle East Tech Univ METU, Inst Appl Math, TR-06590 Ankara, Turkey
关键词
deep learning; convolutional neural network (CNN); computed tomography (CT) images; micro-CT; reduced exposure time; efficient CT measurement; enhanced temporal resolution; improved image quality; rock (porous medium) images; ASTRA toolbox; INDUSTRIAL APPLICATIONS; IMAGE NOISE; CT; RESOLUTION; RECONSTRUCTION; SEGMENTATION; ACCURACY; PLATFORM; SIZE;
D O I
10.3390/s21051921
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Deep neural networks have received considerable attention in clinical imaging, particularly with respect to the reduction of radiation risk. Lowering the radiation dose by reducing the photon flux inevitably results in the degradation of the scanned image quality. Thus, researchers have sought to exploit deep convolutional neural networks (DCNNs) to map low-quality, low-dose images to higher-dose, higher-quality images, thereby minimizing the associated radiation hazard. Conversely, computed tomography (CT) measurements of geomaterials are not limited by the radiation dose. In contrast to the human body, however, geomaterials may be comprised of high-density constituents causing increased attenuation of the X-rays. Consequently, higher-dose images are required to obtain an acceptable scan quality. The problem of prolonged acquisition times is particularly severe for micro-CT based scanning technologies. Depending on the sample size and exposure time settings, a single scan may require several hours to complete. This is of particular concern if phenomena with an exponential temperature dependency are to be elucidated. A process may happen too fast to be adequately captured by CT scanning. To address the aforementioned issues, we apply DCNNs to improve the quality of rock CT images and reduce exposure times by more than 60%, simultaneously. We highlight current results based on micro-CT derived datasets and apply transfer learning to improve DCNN results without increasing training time. The approach is applicable to any computed tomography technology. Furthermore, we contrast the performance of the DCNN trained by minimizing different loss functions such as mean squared error and structural similarity index.
引用
收藏
页码:1 / 17
页数:17
相关论文
共 52 条
[1]   Machine learning for predicting properties of porous media from 2d X-ray images [J].
Alqahtani, Naif ;
Alzubaidi, Fatimah ;
Armstrong, Ryan T. ;
Swietojanski, Pawel ;
Mostaghimi, Peyman .
JOURNAL OF PETROLEUM SCIENCE AND ENGINEERING, 2020, 184
[2]  
[Anonymous], 199DEV1 DOCUMENTATIO
[3]  
[Anonymous], 1983, Medical Imaging Systems
[4]  
Astra-Toolbox, ASTR TOOLB ASTR TOOL
[5]  
Avsar TS., 2017, P EUROPEAN MEDICAL B, P414
[6]   Artifacts in CT: Recognition and avoidance [J].
Barrett, JF ;
Keat, N .
RADIOGRAPHICS, 2004, 24 (06) :1679-1691
[7]   Application of computed tomography (CT) in reverse-engineering technology [J].
Bartscher, Markus ;
Hilpert, Uwe ;
Goebbels, Juergen ;
Weidemann, Gerd ;
Puder, Holm ;
Jidav, Horia-Nicolae .
MATERIALPRUFUNG, 2006, 48 (06) :305-311
[8]   Accuracy analysis of a piece-to-piece reverse engineering workflow for a turbine foil based on multi-modal computed tomography and additive manufacturing [J].
Bauer, Fabian ;
Schrapp, Michael ;
Szijarto, Janos .
PRECISION ENGINEERING-JOURNAL OF THE INTERNATIONAL SOCIETIES FOR PRECISION ENGINEERING AND NANOTECHNOLOGY, 2019, 60 :63-75
[9]   Effect of CT image size and resolution on the accuracy of rock property estimates [J].
Bazaikin, Y. ;
Gurevich, B. ;
Iglauer, S. ;
Khachkova, T. ;
Kolyukhin, D. ;
Lebedev, M. ;
Lisitsa, V. ;
Reshetova, G. .
JOURNAL OF GEOPHYSICAL RESEARCH-SOLID EARTH, 2017, 122 (05) :3635-3647
[10]   Industrial applications of digital rock technology [J].
Berg, Carl Fredrik ;
Lopez, Olivier ;
Berland, Havard .
JOURNAL OF PETROLEUM SCIENCE AND ENGINEERING, 2017, 157 :131-147