Performance of a Commercial Macro Monte Carlo Dose Calculation Algorithm for Determining Output Factors of Clinical Electron Fields

被引:5
作者
Popple, Richard A. [1 ]
Brezovich, Ivan A. [1 ]
Pareek, Prem N. [1 ]
Duan, Jun [1 ]
Shen, Sui [1 ]
Wu, Xingen [1 ]
机构
[1] Univ Alabama Birmingham, Dept Radiat Oncol, Birmingham, AL 35294 USA
关键词
Electron; Macro Monte Carlo; Monte Carlo; Treatment planning; Dose calculation;
D O I
10.1177/153303460900800407
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
We compare measured output factors of clinical electron fields to those calculated by a commercial treatment planning system based on an electron Monte Carlo algorithm. The measured data is comprised of 195 fields with energies 6 to 18 MeV, applicator sizes 6 x 6 cm(2) to 25 x 25 cm(2), and source to surface distances (SSDs) of 97 to 107 cm. Due to a scarcity of clinical fields for the highest energies and the largest applicator sizes, additional measurements were made at arbitrarily chosen large field sizes at previously not used energies, for a total of 223 output factors. The difference between calculation and measurement ranged from -2.9% to 3.9%, with a mean difference of -0.2%. Half of the field shapes had a difference with magnitude less than 0.8%. Only 7 (3%) of the field shapes were outliers, having differences greater than 2%. All outliers had field widths at the normalization point < 3.5 cm, were applied at SSDs > 100 cm, were inserts for the 25 x 25 cm(2) applicator, or had more than one of these characteristics. For narrow and elongated fields the TPS slightly overestimated output factors, whereas for field shapes with aspect ratio close to 1 the TPS slightly underestimated the output factors. No strong dependence of the difference on energy was observed.
引用
收藏
页码:307 / 314
页数:8
相关论文
共 17 条
[1]  
[Anonymous], LAUR031987 LOS AL NA
[2]  
*CERN, 1995, W5013 CERN APPL SOFT
[3]   First macro Monte Carlo based commercial dose calculation module for electron beam treatment planning - new issues for clinical consideration [J].
Ding, George X. ;
Duggan, Dennis M. ;
Coffey, Charles W. ;
Shokrani, Parvaneh ;
Cygler, Joanna E. .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (11) :2781-2799
[4]  
Hu YA, 2008, J APPL CLIN MED PHYS, V9, P1, DOI 10.1120/jacmp.v9i3.2720
[5]   Monte Carlo calculations of electron beam output factors for a medical linear accelerator [J].
Kapur, A ;
Ma, CM ;
Mok, EC ;
Findley, DO ;
Boyer, AL .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (12) :3479-3494
[6]  
KAWRAKOV I, 2000, PIRS701 NAT RES COUN
[7]   3D electron dose calculation using a Voxel based Monte Carlo algorithm (VMC) [J].
Kawrakow, I ;
Fippel, M ;
Friedrich, K .
MEDICAL PHYSICS, 1996, 23 (04) :445-457
[8]   Super-Monte Carlo: A 3-D electron beam dose calculation algorithm [J].
Keall, PJ ;
Hoban, PW .
MEDICAL PHYSICS, 1996, 23 (12) :2023-2034
[9]  
Khan F. M., 2003, PHYS RAD THERAPY, V3rd
[10]   CLINICAL ELECTRON-BEAM DOSIMETRY - REPORT OF AAPM RADIATION-THERAPY COMMITTEE TASK GROUP NO-25 [J].
KHAN, FM ;
DOPPKE, KP ;
HOGSTROM, KR ;
KUTCHER, GJ ;
NATH, R ;
PRASAD, SC ;
PURDY, JA ;
ROZENFELD, M ;
WERNER, BL .
MEDICAL PHYSICS, 1991, 18 (01) :73-109