Ultrasound-guided renal access and balloon dilation for PCNL in the prone position: results of a multicenter prospective observational study

被引:4
|
作者
Su, Boxing [1 ]
Song, Haifeng [1 ]
Yang, Zesong [2 ]
Yang, Wenzeng [3 ]
An, Feng [3 ]
Chen, Fangzhi [4 ]
He, Peng [5 ]
Li, Gonghui [6 ]
Wu, Haiyang [6 ]
Yang, Jinjian [7 ]
Li, Songchao [7 ]
Liu, Yubao [1 ]
Bai, Wenjie [1 ]
Wang, Shu [1 ]
Xiao, Bo [1 ]
Hu, Weiguo [1 ]
Li, Jianxing [1 ]
机构
[1] Tsinghua Univ, Beijing Tsinghua Changgung Hosp, Sch Clin Med, Dept Urol, 168 Litang Rd, Beijing, Peoples R China
[2] Fujian Prov Hosp, Dept Urol, Fuzhou, Fujian, Peoples R China
[3] Hebei Univ, Dept Urol, Affiliated Hosp, Baoding, Peoples R China
[4] Cent South Univ, Dept Urol, Xiangya Hosp 2, Changsha, Peoples R China
[5] Univ Elect Sci & Technol China, Sichuan Prov Peoples Hosp, Dept Urol, Chengdu, Peoples R China
[6] Zhejiang Univ, Sir Run Run Shaw Hosp, Dept Urol, Sch Med, Hangzhou, Peoples R China
[7] Zhengzhou Univ, Dept Urol, Affiliated Hosp 1, Zhengzhou, Henan, Peoples R China
基金
北京市自然科学基金;
关键词
Percutaneous nephrolithotomy; Balloon dilation; Ultrasound; Renal access; Tract establishment; PERCUTANEOUS NEPHROLITHOTOMY; GUIDANCE; SAFETY;
D O I
10.1007/s00345-022-04072-6
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Purpose To investigate the safety and efficacy of ultrasound-guided renal access and tract dilation using balloon dilators, as well as to identify suitable patients for this technique. Methods Consecutive patients undergoing ultrasound-guided PCNL using balloon dilators between December 2019 and June 2020 in seven large medical centers from China were prospectively enrolled. Demographic and perioperative parameters of the patients were collected. Logistic regression analysis was used to analyze factors that would affect the success rate of tract establishment using ultrasound-guided renal access and balloon dilation. Results A total of 170 patients were included in this study, among whom, 91.18% of the (155/170) patients had a successful tract establishment under ultrasound guidance on the first attempt. The stone-free rate was 83.5% and postoperative complications occurred in 14 patients (8.23%). In univariate analysis, history of ipsilateral surgery (p = 0.026), and stone diameter (p = 0.01) were significantly associated with tract establishment failure, while a larger width of the target calyx (p = 0.016) and the presence of hydronephrosis (p = 0.001) were significantly associated with a successful tract establishment. In multivariate analysis, only hydronephrosis in target calyx (p = 0.027) was a favorable factor for successful tract establishment, and the history of ipsilateral renal surgery (p = 0.012) was the only independent risk factor for failure of tract establishment. Conclusion It was safe and effective to establish percutaneous renal access with balloon dilation under whole-process ultrasound monitoring during PCNL. Furthermore, patients with a hydronephrotic target calyx and without history of ipsilateral renal surgery were most suited to this technique. Trial registration CHiCTR1800014448.
引用
收藏
页码:2339 / 2345
页数:7
相关论文
共 36 条
  • [31] Usefulness of Ultrasound-guided Measurement of Minimal Transverse Diameter of Subglottic Airway in Determining the Endotracheal Tube Size in Children with Congenital Heart Disease: A Prospective Observational Study
    Pillai, Rahul
    Kumaran, Suresh
    Jeyaseelan, L.
    George, Sajan P.
    Sahajanandan, Raj
    ANNALS OF CARDIAC ANAESTHESIA, 2018, 21 (04) : 382 - 387
  • [32] Randomized, prospective, observational simulation study comparing residents' needle-guided vs free-hand ultrasound techniques for central venous catheter access
    Ball, R. D.
    Scouras, N. E.
    Orebaugh, S.
    Wilde, J.
    Sakai, T.
    BRITISH JOURNAL OF ANAESTHESIA, 2012, 108 (01) : 72 - 79
  • [33] Ultrasound-guided central line insertion and standard peripherally inserted catheter placement in preterm infants: Comparing results from prospective study in a single-center
    Al Hamod, Dany Antanios
    Zeidan, Smart
    Al Bizri, Ayah
    Baaklini, Georges
    Nassif, Yolla
    NORTH AMERICAN JOURNAL OF MEDICAL SCIENCES, 2016, 8 (05) : 205 - 209
  • [34] Evaluation of tissue oxygenation and block quality using Near Infrared Spectroscopy (NIRS) in patients undergoing ultrasound-guided infraclavicular block at different arm angles A prospective observational study
    Binici, Orhan
    Karahan, Mahmut Alp
    Buyukfirat, Evren
    ANNALI ITALIANI DI CHIRURGIA, 2019, 90 (04) : 357 - 363
  • [35] Ultrasound-guided central venous catheterization in cancer patients improves the success rate of cannulation and reduces mechanical complications: A prospective observational study of 1,978 consecutive catheterizations
    Cavanna, Luigi
    Civardi, Giuseppe
    Vallisa, Daniele
    Di Nunzio, Camilla
    Cappucciati, Lorella
    Berte, Raffaella
    Cordani, Maria Rosa
    Lazzaro, Antonio
    Cremona, Gabriele
    Biasini, Claudia
    Muroni, Monica
    Mordenti, Patrizia
    Gorgni, Silvia
    Zaffignani, Elena
    Ambroggi, Massimo
    Bidin, Livia
    Palladino, Maria Angela
    Rodino, Carmelina
    Tibaldi, Laura
    WORLD JOURNAL OF SURGICAL ONCOLOGY, 2010, 8
  • [36] Comparison of the Results of Ultrasound-Guided Thoracic Paravertebral Block and Modified Pectoral Nerve Block for Postoperative Analgesia in Video-Assisted Thoracoscopic Surgery: A Prospective, Randomized Controlled Study
    Yildirim, Kubra
    Sertcakacilar, Gokhan
    Hergunsel, Gulsum Oya
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2022, 36 (02) : 489 - 496